Beware of recent phishing e-mails. Use our official contact addresses only.
413-284-9975
Adaptas

Search Literature / "filament"

Pages containing matching text:
Reference Literature
Note 92: Yttria Coated Mass Spectrometer Filaments Note 92: Yttria Coated Mass Spectrometer Filaments - Yttria Coated MS Filaments - </referenc/applnote/app-92.htm> /5
Note 96: Reducing Warping in Mass Spectrometer Filaments, with SISAlloy® Yttria/Rhenium Filaments Note 96: Reducing Warping in Mass Spectrometer Filaments, with SISAlloy® Yttria/Rhenium Filaments - By John J. Manura, Christopher Baker & Ronald Shomo Scientific Instrument Services, Ringoes, NJ Presented at the ASMS Meeting in Denver, CO, June 2011 Introduction Filament warping is a significant problem in the mass spectrometer especially in Chemical Ionization (CI) sources where the ion entrance hole is small. Different filament materials and geometry have been used to reduce or eliminate this problem. Various wire geometries including ribbon filaments, straight wire filaments, coils an... - </referenc/applnote/app-96-reduce-ms-filament-warping.htm> /5
Abstract - Application of SIMION to Filament Design for MS source Abstract - Application of SIMION to Filament Design for MS source - Application of SIMION to Filament Design for MS source - </referenc/abstract/simion1.htm> /5
Note 45: Application of SIMION 6.0 to Filament Design for Mass Spectrometer Ionization Sources Note 45: Application of SIMION 6.0 to Filament Design for Mass Spectrometer Ionization Sources - Application of SIMION 6.0 to Filament Design for Mass Spectrometer Ionization Sources - </referenc/applnote/app-45.htm> /5
SIS Newsletter 2012-05-15 SIS Newsletter 2012-05-15 - SIS will be at the ASMS Meeting in Vancouver - May 21-24 Visit us at Booth # 32 Introducing many new products, including Yttria filaments, plus SIMION 8.1.1 demos/training Mon-Wed. NEW! - Long Life Yttria Coated Filament Repairs 2-3 ~ Times the Filament Life of Normal Mass Spectrometer Filaments SIS can now repair your filaments with Yttria coated rhenium alloy wires and coils to replace the standard rhenium uncoated filaments. SIS repairs your filaments with our non-sagging rhenium alloy filam... - </news/enews/20120515.htm> /5
Frequently Asked Questions Frequently Asked Questions - We get many questions from customers to aid them in the use of their instruments. We will publish these questions and answers here to aid other instrument users. We welcome both your questions and answers to problems that you have encountered. In addition we welcome additional or corrective comments to any of our questions. Question - The spectrum of my mass spectrometer has poor resolution and low sensitivity. It is a magnetic sector instrument with diffusion pumps. We changed the source, fila... - </index/sis/question.htm> /5
Article - Design of the DEP Probe for the HP 5989 MS Article - Design of the DEP Probe for the HP 5989 MS - The most common method for the direct introduction of samples into a mass spectrometer is routinely accomplished with the use of a direct insertion probe (DIP). - </referenc/articles/probe1.htm> /5
Note 91: AutoProbe DEP Probe Tip Temperatures Note 91: AutoProbe DEP Probe Tip Temperatures - AutoProbe DEP Probe Tip Temperatures - </referenc/applnote/app-91.htm> /5
Note 87: Design and Development of an Automated Direct Probe for a Mass Spectrometer Note 87: Design and Development of an Automated Direct Probe for a Mass Spectrometer - Design and Development of an Automated Direct Probe for a Mass Spectrometer - </referenc/applnote/app-87.htm> /5
Extending Electron Multiplier Life 4500 Extending Electron Multiplier Life 4500 - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip17.htm> /5
Scientific Instrument Services, Laboratory Instrument Supplies Scientific Instrument Services, Laboratory Instrument Supplies - SIS supplies new parts for your laboratory instruments. We sell replacement parts for Thermo Fisher scientific equipment, Agilent Mass Spectrometers, Shimadzu mass spectrometers, and others. - </index/sis/company.htm> /5
Note 70: Application of SIMION 6.0 To a Study of the Finkelstein Ion Source: Part II Note 70: Application of SIMION 6.0 To a Study of the Finkelstein Ion Source: Part II - Application of Simion to a study of the Finkelstein Ion Source, Part II - </referenc/applnote/app-70.htm> /5
Article - Mass Spec Source Cleaning Procedures, J. Manura Article - Mass Spec Source Cleaning Procedures, J. Manura - John J. Manura Scientific Instrument Services Finnigan 3200, HP5971 and HP5970 Sources In Volume I of the Mass Spec Handbook of Service (Scientific Instrument Services, #MSHS-1, 1983), we published a series of articles on the cleaning of mass spectrometer sources and other mass spectrometer parts. These articles described a wide range of techniques and available equipment for the cleaning of metal parts, ceramics and other insulating materials. Over the last 10 years, we have refined several of ... - </ms/sis-serv/cleanart.htm> /5
SIS Newsletter 2009-09-22 SIS Newsletter 2009-09-22 - Scientific Instrument Services Newsletter The SIS E-Newsletter is intended to notify our customers of new products and special promotions of products and services for your mass spectrometer and related laboratory equipment. Featured Products and Promotions September 22, 2009 Isotope Abundance Analysis (IAA) Software New - Enhances NIST MS Library Search ... - </news/enews/20090922.htm> /5
SIS Newsletter 2011-05-20 SIS Newsletter 2011-05-20 - subscribe to this newsletter | previous newsletter Scientific Instrument Services Newsletter The SIS E-Newsletter is intended to notify our customers of new products and special promotions of products and services for your mass spectrometer and related laboratory equipment. Featured Products and Promotions June 01, 2011 NIST 2011 - New Version A major new release of the Mass Spectral Library A major new release of the world's most widely used and trusted, fully evaluated, mass spectral library, ... - </news/enews/20110523.htm> /5
Note 69: Application of SIMION 6.0 To a Study of the Finkelstein Ion Source: Part 1 Note 69: Application of SIMION 6.0 To a Study of the Finkelstein Ion Source: Part 1 - Application of SIMION 6.0 To a Study of the Finkelstein Ion Source: Part 1 - </referenc/applnote/app-69.htm> /5
Literature Flyers/Brochures from SIS Literature Flyers/Brochures from SIS - PDF flyers and brochures for SIS products. - </index/sis/flyers.htm> /5
AutoProbe General Description - Automated Direct Probe for the ThermoQust AutoProbe General Description - Automated Direct Probe for the ThermoQust - The AutoProbe™ System is an Automated Direct Exposure Probe (DEP) for the Finnigan PolarisQ™ and TRACE DSQ™ Mass Spectrometer Systems. - </autoprobe/ap2000/autopro2.htm> /5
Note 89: Quantitation of Organics via a Mass Spectrometer Automated Direct Probe Note 89: Quantitation of Organics via a Mass Spectrometer Automated Direct Probe - Quantitation of Organics via a Mass Spectrometer Automated Direct Probe - </referenc/applnote/app-89.htm> /5
MS Tip - Repairing Clogged Thermospray Probes MS Tip - Repairing Clogged Thermospray Probes - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip7.htm> /5
MS Tip - Trouble Shooting Finnigan 5100 GC/MS Systems MS Tip - Trouble Shooting Finnigan 5100 GC/MS Systems - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip10.htm> /5
Abstract - Development of an Automated Pyrolysis System Abstract - Development of an Automated Pyrolysis System - Development and Field Tests of an Automated Pyrolysis Insert for GC - </referenc/abstract/pyrolys2.htm> /5
Note 90: An Automated MS Direct Probe for use in an Open Access Environment Note 90: An Automated MS Direct Probe for use in an Open Access Environment - An Automated MS Direct Probe for use in an Open Access Environment - </referenc/applnote/app-90.htm> /5
Improving Sensitivity in the HP 5971 MSD and other MS - Part 1 of 2 Improving Sensitivity in the HP 5971 MSD and other MS - Part 1 of 2 - The H.P. MSD instruments (Models 5970, 5971 and 5972) have proven to be very efficient, low cost, highly sensitive and versatile mass spectrometers. - </referenc/articles/sensit-1.htm> /5
What's New - 9/95 through 12/95 What's New - 9/95 through 12/95 - Posted 12/4/95 Search System of SIS Internet Pages A new Search System has been installed into our Internet pages to enable you to easily find parts, products or resource materials on out pages. Our Internet pages have increased to more than 700 pages to date and will expand to 3 or 4 times that amount within the next year. We hope that this search system will prove useful to locate the needed resources. In addition to the Search function we have also added an E-Mail Write us Button on the bott... - </index/sis/news1295.htm> /1
MS Tip - Electron Multiplier Sensitivity MS Tip - Electron Multiplier Sensitivity - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip15.htm> /5
MS Tip: Mass Spectrometer Source Cleaning Procedures MS Tip: Mass Spectrometer Source Cleaning Procedures - Revised 6/1/02 Copyright: Scientific Instrument Services, June 2002, All rights reserved by John J. Manura, Scientific Instrument Services, Ringoes, NJ The following is a compilation of the procedures used by Scientific Instrument Services for the cleaning of mass spectrometer sources over the last 25 years. This article incorporates the current techniques used at SIS as well as procedures reported in our Mass Spec Handbook of Service (published in 1983 and now out of print), articles published ... - </referenc/tips/msclean.htm> /5
Archive of Mass Spec Source Newsletters Archive of Mass Spec Source Newsletters - A newsletter designed for the mass spec community. Published by Scientific Instrument Services, Inc. Includes featured products, MS articles, tips, items for sale, ... - </news/newsletter.htm> /5
Note 81: Rapid Bacterial Chemotaxonomy By Direct Probe/MSD Note 81: Rapid Bacterial Chemotaxonomy By Direct Probe/MSD - Rapid bacterial Chemotaxonomy by Direct Probe/MSD - </referenc/applnote/app-81.htm> /5
Note 56: Mass Spec Maintenance & Cleaning Utilizing Micro-Mesh® Abrasive Sheets Note 56: Mass Spec Maintenance & Cleaning Utilizing Micro-Mesh® Abrasive Sheets - Micro-Mesh® abrasives are used to clean scientific instrument parts - </referenc/applnote/app-56.htm> /5
SIS Mass Spec Source Newsletter, May 1996 SIS Mass Spec Source Newsletter, May 1996 - VOL. XXI, NO. 1 May 1996 Contents 1. ASMS 96 Meeting in Portland Oregon 2. SIS Poster Presentations at the 1996 ASMS Meeting 3. SIS Hospitality Suite at the 1996 ASMS Meeting 4. SIS on the World Wide Web 5. New Micro Cryo-Trap 6. SIS Now Distributes Edwards Vacuum Pumps 7. Free Catalog of Scientific, Engineering and Technical Software 8. SIMION 3D Electron Ion Optics Software - Now Available from SIS ASMS 96 Meting in Portland Oregon Scientific Instrument Services will once again be present at ... - </news/may1996.htm> /5
MS Tip - Tuning a Finnigan 5100 to Meet BFB or DFTPP Criteria MS Tip - Tuning a Finnigan 5100 to Meet BFB or DFTPP Criteria - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip8.htm> /5
Mass Spectrometer Source Cleaning Methods Mass Spectrometer Source Cleaning Methods - Note: This article on MS source cleaning methods was published in the SIS Mass Spec Source Newsletter. Please instead see MS Tips: Mass Spectrometer Source Cleaning Methods for the latest version of this article. Scientific Instrument Services, Inc. June 2002 Mass Spectrometer Source Cleaning Methods Revised 6/1/02 Copyright: Scientific Instrument Services, June 2002, All rights reserved by John J. Manura, Scientific Instrument Services, Ringoes, NJ The following is a compilation of the procedu... - </news/source.htm> /5
SIS Newsletter: Vacuum Pumps and Accessories (April 23, 2012) SIS Newsletter: Vacuum Pumps and Accessories (April 23, 2012) - In this issue: New vacuum pumps and accessories available from SIS. NEW! - SIS Rotary Vane Vacuum Pumps 35% - 50% Less than the Price of Other Vacuum Pumps SIS has just introduced a new line of our own Rotary Vane Vacuum Pumps for Mass Spectrometers and other scientific instruments at more affordable prices. Low Cost - Save 35%-50% Savings Extremely Quiet and Light Weight Air Cooled Direct Drive Designed for Continuous Duty 110V or 220V Ideal for Mass Spectrometers Reliable 20 Year History Idea... - </news/enews/20120423.htm> /5
Article - Micro-Mesh® Cleaning Abrasives for Cleaning MS Parts Article - Micro-Mesh® Cleaning Abrasives for Cleaning MS Parts - Article on Micro-Mesh® - </ms/sis-serv/micromes.htm> /5
MS Tip - Evaluating multipliers to determine when to replace MS Tip - Evaluating multipliers to determine when to replace - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip18.htm> /5
MS Tip - Techniques used to evaluate vacuum leaks in the MS MS Tip - Techniques used to evaluate vacuum leaks in the MS - Mass Spec Tips is a collection of tips relating to the operation and service of mass spectrometers. - </index/referenc/tip19.htm> /5
Note 53: SIMION 3D v6.0 Ion Optics Simulation Software Note 53: SIMION 3D v6.0 Ion Optics Simulation Software - Study of Ion Optics using the Simion 3D sopftware package - </referenc/applnote/app-53.htm> /5
What's New - 1/97 through 12/97 What's New - 1/97 through 12/97 - Posted 9/1/97 Chemical Reaction Interface Mass Spectrometry (CRIMS) Scientific Instrument Services is currently developing both GC and LC CRIMS systems. These products are based on the work and methods of Fred Abramson of George Washington University. The GC CRIMS system has been built and is currently being tested in our laboratory. The GC-CRIMS systems will be introduced at the EAS meeting in Sommerset, NJ in November and will available for delivery this fall. Over the next few months we will... - </index/sis/news1997.htm> /1
SIS Mass Spec Source Newsletter, June 2001 SIS Mass Spec Source Newsletter, June 2001 - VOL. XXIII, NO. 1 Scientific Instrument Services, Inc. June 2001 This is the first edition of the SIS Mass Spec Source Newsletter via our Web Site. We anticipate that we will send this communication out once every 2 months. In it we will keep you informed of news at SIS, trade shows that we will be attending, new products being introduced and promotions on products. To receive your copy of this newsletter or to get on our mail list, please fill out our survey form. You are being sent this newsl... - </news/jun2001.htm> /1
What's New - 1/98 through 12/99 What's New - 1/98 through 12/99 - Posted 3/15/99 AutoDesorb - Automated Short Path Thermal Desorption SIS introduced the new AutoDesorb System at PittCon 99. This PC Controlled Automated Short Path Thermal Desorption System is designed for the continuous and unattended thermal extraction of volatile and semi-volatile organics from solid, liquid and gas samples for analysis by GC and GC/MS. The new AutoDesorb System is the automated sampling version of the patented SIS Short Path Thermal Desorption System. It is designed for the... - </index/sis/news1299.htm> /1
What's New - 1/00 through 12/01 What's New - 1/00 through 12/01 - Posted 5/03/01 SIS at the ASMS meeting in Chicago - Annual SIS Ice Cream Hospitality Suite SIS will be attending the ASMS meeting on May 27 to May 31, 2001 at the Hyatt Regency Hotel in Chicago. Stop by the SIS Booth during the meeting, The Tradition Continues at ASMS Once again we will be sponsoring our Ice Cream Sundae Hospitality Suite at the Atlanta room in the Hyatt Regency Hotel. We will be serving ice cream sundaes from approximately 7:30 p.m. until 9:30 pm, on Monday, Tuesday and Wednes... - </index/sis/news2001.htm> /1
What's New - 1/1/96 through 6/30/96 What's New - 1/1/96 through 6/30/96 - Posted 4/29/96 SIS Mass Spec Source Newsletter - On Line - May 1996 The May 1996 issue of the SIS Mass Spec Source Newsletter was just mailed to our customers on May 25, 1996. In addition we are making the contents available on the Internet. The format is slightly different, but all the information and much more is present here. Posted 4/29/96 ASMS 96 Meeting in Portland Oregon Scientific Instrument Services will once again be present at this years ASMS meeting. The meeting will be held the wee... - </index/sis/news0696.htm> /1
What's New - 1/99 through 12/00 What's New - 1/99 through 12/00 - Posted 5/29/00 NEW from SIS - E-Mail Newsletter Beginning in July 2000, SIS will distribute an E-Mail Newsletter. Distribution is expected to be monthly. This newsletter will feature new products, special promotions and the latest information from SIS. To receive this E-Mail Newsletter you must sign up to get on this mail list. Posted 5/29/00 SIS Mass Spec Newsletter - Latest Edition Now Online The latest edition of the SIS Newsletter is now available on our Web site. Includes an article on ins... - </index/sis/news2000.htm> /1
SIS™ On Line (Catalog 2) SIS™ On Line (Catalog 2) - 3. SIS™ International Dealers 4. Ordering Information 5. Ordering Information 6. New Products From SIS™ 7. New Products From SIS™ 8. New Products From SIS™ 9. New Products From SIS™ 10. New Products From SIS™ 11. New Products From SIS™ 12. New Products From SIS™ 13. New Products From SIS™ 14. New Products From SIS™ - </catalog/36/2> /5