Home
- ▶
- Heaters/Source
- ▶
- Agilent Heaters and SensorsMass Spectrometry, Scientific Supplies & ManufacturingScientific Instrument Services 5973 Source Heater Tamper Resistant Allen Wrench 5973/5975 Quad Sensor 5985 Source Heater Assembly Agilent Interface Heater Assembly 5971 Interface Heater
- ▶
- MS - Agilent/HPAgilent/HP part number cross reference 5977 5975 5973 5972 5971 5970 MSD GCD 5992/5993/5995 5985/5986/5987/5988 5989 7000 4500 6100 6200 6300 6400 6500 7500 Filaments Multipliers Source Heaters & Sensors Vacuum Transfer Line Supplies Probes Baseplate O-Ring for 5973/5975/5977 Ceramic Insulators ESI/Jet Separator Tools Autosampler GC Supplies Other Supplies Mass Spectral Libraries (NIST 23 and Wiley Libraries) All Repairs Filament Repair Source Cleaning Catalog Page A43 Catalog Page B14
- ▶
- 5972 (This Page)
The Agilent/HP 5972 MSD is a quadrupole MS, released circa 1992. It interfaces to an 5890 or 6890. It follows the Agilent/HP 5971 and is preceded by the HP/Agilent 5973.
SIS provides various supplies and services for the 5972.
Replacement Parts for the Agilent/HP 5972
- Electron Multipliers for the Agilent/HP 5972 SIS provides replacement detectors for your Agilent 5972 mass spectrometer. Multipliers are from the major manufacturers of electron multipliers.
- Autosampler Vials Vials are manufactured from Type 1 borosilicate glass tubing to hold uniform wall thickness.
- Brass Nut Available in packages of 5 nuts.
- Ion Gauge Tubes Our standard G75K Bayard-Alpert ion gauge tube will fit all models of HP mass specs except the HP5989 MS Engine.
- Syringes, Autosampler A comprehensive range of syringes for GC autosamplers is available.
- NW50 plastic Viton® CO-SEAL
- MS Calibration Compounds Calibration compounds with a mass range for many uses and needs.
- Mass Spec Source Cleaning Service at SIS Expert cleaning & repair of mass spectrometer sources.
- The NIST 23 Mass Spectral Library
& Search Software (NIST 2023/2020/2017/EPA/NIH)Get new licenses for NIST mass spectral library, EI MS spectra, MS/MS, GC data here. Includes electron ionization (EI) data, AMDIS software. Standard, Agilent, Shimadzu, Multiformat available. - Mass Spectral Libraries
(NIST 23 and Wiley Libraries)Identify unknowns from EI (GC/MS) and MS/MS spectra. The most trusted, largest, and widely used libraries. - SGE GC Capillary Columns SGE capillary columns for gas chromatography.
- GC Injection Port Liners Glass and quartz GC injection port liners.
- GC Septa by Manufacturer GC septa by SGE and other manufactures.
- SIS GC Cryo-Traps Cryo-cooling and heating trap for the cryo-focusing of volatiles and semivolatiles at the head of GC capillary columns.
- GC Ferrules GC ferrules by SGE and other manufacturers. Graphite Vespel®, graphitized vespel and PTFE ferrules.
- Syringes
(GC)A complete line of SGE syringes for GC. - Analytical Standards 8DS001 : -,8IS001 : -,8IS00110 : -,8IS002 : -,8IS003 : -,8IS005 : -,8IS006 : -,8IS008 : -,8IS00810 : -,8IS010 : -,8LS004 : -,8LS007 : -,8PK005 : -,8PK006 : -,8PM001 : -,8PM002 : -,8PM003 : -,8PM004 : -,8PM005 : -,8PM006 : -,8PM007 : -,8PM008 : -,8PM009 : -,8SI001 : -,8SI002 : -,8SI00210 : -,8SI003 : -,8SI00310 : -,8SI004 : -,8SI00410 : -,8SM00110 : -,8SM002 : -,8SM00310 : -,8SM004 : -,8SM005 : -,8SM006 : -,8SM007 : -,8SM008 : -,8SM009 : -,8SM009CON : -,8SM010D : -,8SM010IPA : -,8SS001 : -,8SS001...
- SIS Short Path Thermal Desorption Systems Short Path Thermal Desorption Systems for the analysis of volatiles and semi-volatiles by GC and GC/MS. Systems, accessories, and application notes.
- Foreline Gauge Assembly for Agilent Replaces Agilent/HP Part #G1099-60545.
- Vacuum Pumps and Supplies from SIS Vacuum pumps by SIS, Edwards, Adixen and Pfeiffer.
- SIS All-In-One Pump Filter Kit for Pfeiffer 6.25" high, low cost, combined oil mist eliminator and charcoal filter proven effective for removing volatile and semi-volatile organics from exhaust of vacuum pumps.
- Santovac® 5P Ultra Vacuum Pump Fluid Santovac 5P Ultra has the same properties of Santovac 5 but guarantees minimal amounts of the 3 and 4 ring polyphenyl ethers; less than .02% and .1% respectively and for ultra-clean applications such as mass spectrometry.
- Mechanical Pump Oils Mechanical Pump Oils for your vacuum rough pump needs.
- Diffusion Pump Fluids Pump Fluids for your lab needs.
- Convectron Series 275 Vacuum Gauge The Granville Philips Convectron Gauge tube used on the 5971 and 5972 mass spectrometers is available from S.I.S. This is a direct replacement for the HP original and screws into the fitting shown above.
- Rollerflex Vacuum Hose PVC cord reinforced vacuum hose. Light weight, low cost, and superior corrosion resistance. Ideal for mass spec, food, and other applications.
- Vacuum Hose: Steel Wire Reinforced This food and beverage grade, crystal clear PVC tubing is reinforced with 110 ton psi steel spring wire.
- Vacuum Fittings Many Fittings and Flanges in different sizes for your vacuum needs.
Repair Services for the Agilent/HP 5972
- Filament Repair
- Filament Repair, 5971
- Source Cleaning, 5972 Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven.