Home
- ▶
- Heaters/Source
- ▶
- Agilent Heaters and SensorsMass Spectrometry, Scientific Supplies & ManufacturingScientific Instrument Services 5973 Source Heater Tamper Resistant Allen Wrench 5973/5975 Quad Sensor 5985 Source Heater Assembly Agilent Interface Heater Assembly 5971 Interface Heater
- ▶
- MS - Agilent/HPAgilent/HP part number cross reference 5977 5975 5973 5972 5971 5970 MSD GCD 5992/5993/5995 5985/5986/5987/5988 5989 7000 4500 6100 6200 6300 6400 6500 7500 Filaments Multipliers Source Heaters & Sensors Vacuum Transfer Line Supplies Probes Baseplate O-Ring for 5973/5975/5977 Ceramic Insulators ESI/Jet Separator Tools Autosampler GC Supplies Other Supplies Mass Spectral Libraries (NIST 23 and Wiley Libraries) All Repairs Filament Repair Source Cleaning Catalog Page A43 Catalog Page B14
- ▶
- 5975 (This Page)
The Agilent 5975 MSD is a quadrupole MS, released circa ~2005. It interfaces to the Agilent 6890 or 7890 GC. Variants include the 5975 inert circa 2005, 5975B circa 2006, 5975C circa 2007 (Agilent 7890A GC), and 5975 LTM circa 2010. The triple-axis detector (TAD) for the 5975C became available in 2008. It follows the 5973 and is followed by the 5977.
SIS provides various supplies and services for the 5975.
See also Agilent/HP Cross Ref.
Electron Multipliers for the Agilent 5975
SIS provides replacement detectors for your Agilent 5975 mass spectrometer. Multipliers are from the major manufacturers of electron multipliers.Triode Style and Mini Bayard-Alpert Ion Gauge Tubes
Triode and Mini Bayard Alpert style ionization gauge tubes are ideal for use in analytical instrumentationMicro Ion Gauge
(for Agilent 5975/5977)Micro ion vacuum gauge (G3170-80001)
Agilent Heaters and Sensors
Replacement source heaters and temperature sensorsAgilent High Performance Dry Vacuum Pumps
For the Agilent 5973, 5975 and 5977 GC/MS SystemsYttria Coated SISAlloy® (Yttria/Rhenium Alloy) Mass Spec Filaments
SIS can repair your filaments with our non-sagging filament wire (SISAlloy® yttria/rhenium alloy with yttria coating). Users have experienced filament lifetime increases of 2 to 3 times compared to the standard uncoated rhenium filaments.SIS HPP7 Direct Insertion Probe for the Agilent/HP 5973/5975 MSD
Direct Probe and Probe Inlet System for the HP 5973/5975 MSD mounts on the GC/MS inlet of the MSDMS Calibration Compounds
Calibration compounds with a mass range for many uses and needs.Mass Spec Source Cleaning Service at SIS
Expert cleaning & repair of mass spectrometer sources.The NIST 23 Mass Spectral Library
& Search Software (NIST 2023/2020/2017/EPA/NIH)Get new licenses for NIST mass spectral library, EI MS spectra, MS/MS, GC data here. Includes electron ionization (EI) data, AMDIS software. Standard, Agilent, Shimadzu, Multiformat available.Mass Spectral Libraries
(NIST 23 and Wiley Libraries)Identify unknowns from EI (GC/MS) and MS/MS spectra. The most trusted, largest, and widely used libraries.SGE GC Capillary Columns
SGE capillary columns for gas chromatography.GC Injection Port Liners
Glass and quartz GC injection port liners.GC Septa by Manufacturer
GC septa by SGE and other manufactures.SIS GC Cryo-Traps
Cryo-cooling and heating trap for the cryo-focusing of volatiles and semivolatiles at the head of GC capillary columns.GC Ferrules
GC ferrules by SGE and other manufacturers. Graphite Vespel®, graphitized vespel and PTFE ferrules.Syringes
(GC)A complete line of SGE syringes for GC.Analytical Standards
8DS001 : -,8IS001 : -,8IS00110 : -,8IS002 : -,8IS003 : -,8IS005 : -,8IS006 : -,8IS008 : -,8IS00810 : -,8IS010 : -,8LS004 : -,8LS007 : -,8PK005 : -,8PK006 : -,8PM001 : -,8PM002 : -,8PM003 : -,8PM004 : -,8PM005 : -,8PM006 : -,8PM007 : -,8PM008 : -,8PM009 : -,8SI001 : -,8SI002 : -,8SI00210 : -,8SI003 : -,8SI00310 : -,8SI004 : -,8SI00410 : -,8SM00110 : -,8SM002 : -,8SM00310 : -,8SM004 : -,8SM005 : -,8SM006 : -,8SM007 : -,8SM008 : -,8SM009 : -,8SM009CON : -,8SM010D : -,8SM010IPA : -,8SS001 : -,8SS001...SIS Short Path Thermal Desorption Systems
Short Path Thermal Desorption Systems for the analysis of volatiles and semi-volatiles by GC and GC/MS. Systems, accessories, and application notes.Foreline Gauge Assembly for Agilent
Replaces Agilent/HP Part #G1099-60545.Vacuum Pumps and Supplies from SIS
Vacuum pumps by SIS, Edwards, Adixen and Pfeiffer.SIS All-In-One Pump Filter Kit for Pfeiffer
6.25" high, low cost, combined oil mist eliminator and charcoal filter proven effective for removing volatile and semi-volatile organics from exhaust of vacuum pumps.Santovac® 5P Ultra Vacuum Pump Fluid
Santovac 5P Ultra has the same properties of Santovac 5 but guarantees minimal amounts of the 3 and 4 ring polyphenyl ethers; less than .02% and .1% respectively and for ultra-clean applications such as mass spectrometry.Mechanical Pump Oils
Mechanical Pump Oils for your vacuum rough pump needs.Diffusion Pump Fluids
Pump Fluids for your lab needs.Convectron Series 275 Vacuum Gauge
The Granville Philips Convectron Gauge tube used on the 5971 and 5972 mass spectrometers is available from S.I.S. This is a direct replacement for the HP original and screws into the fitting shown above.Rollerflex Vacuum Hose
PVC cord reinforced vacuum hose. Light weight, low cost, and superior corrosion resistance. Ideal for mass spec, food, and other applications.Vacuum Hose: Steel Wire Reinforced
This food and beverage grade, crystal clear PVC tubing is reinforced with 110 ton psi steel spring wire.Vacuum Fittings
Many Fittings and Flanges in different sizes for your vacuum needs.Baseplate O-Ring for 5973/5975/5977
Large brown viton o-ring.