Agilent/HP 5972/73/75/77 and GCD Source Cleaning

Agilent/HP 5972/73/75/77 and GCD Source Cleaning
Hover over image to zoom
Price: 335
Product ID : REP100
REP100 Source Cleaning of HP 5972/73/75/77/GCD

Description

Mass Spectrometer Source Cleaning

  • Expert cleaning & repair of mass spec sources
  • Filaments repaired and accurately aligned on mass spec source
  • Fast turn-around of your sources for repair

This is NOT an exchange program - The same source that we receive from you is cleaned and repaired and then sent back to you - ready to install into your mass spectrometer.

Scientific Instrument Services now offers a service of mass spectrometer source cleaning. We can clean and service most models of mass spectrometer sources many of which are listed. If your source is not listed please contact us. For sources not listed below please include a copy of the manufacturers assembly instructions and schematic of the source assembly when the parts are sent in for repair.

Cleaning Procedures

The source cleaning article describes in detail the steps and equipment used in the cleaning and repair of all the MS sources that we service at SIS.

Source cleaning begins with the complete disassembly of the source. The metal parts are cleaned and polished, then washed with solvents. The parts are then thoroughly washed in our high temperature ultrasonic cleaner using high purity water and then dried. Finally the metal parts are baked out.

All ceramic insulators are sandblasted, followed by solvent washing and a high temperature bake-out. If broken, most of these ceramics can be replace at no extra cost, with the exception of those with a cost of $50.00 or more. Vespel® insulators are washed and baked out with the same procedures used for the metal parts described above.

If old filaments are included with the source, they are cleaned and repaired using our standard filament cleaning and repair procedures. The filaments are repaired using the standard original filament material used in the original manufacture of the filament. For a complete description of this repair service see the section on Mass Spectrometer Filament Repair and Manufacture.

Not included in the source repairs are the replacement of the filaments, collectors, heaters, screws, target ceramics, repeller insulator, plunger guide or other missing parts. If these parts need to be replaced, this may delay return delivery until we can obtain replacement parts from the manufacturer and additional charges may be incurred. If the source heaters are sent in with the source, additional charges will be incurred if these items are damaged and need additional repairs or replacement.

Parts cleaned: entire source block, lenses, insulators, filament and repeller assembly.

Parts Repaired: two filaments

Not included in the standard source cleaning price: Replacement of missing screws and other metal source parts, filaments and Vespel® lens insulators.

After all parts have been repaired, cleaned and baked out, the source is reassembled in a clean environment in a laminar flow hood. The filament is reinstalled and accurately aligned over the ion source entrance using an optical video microscope system.. The source is checked for resistance leaks due to bad or cracked insulators followed by a thorough visual inspection.

Your source is now ready for installation into your mass spectrometer.

If your source is not listed, it can still be repaired and cleaned by S.I.S. A copy of your source assembly/disassembly schematic from your mass spec manual should be sent in with your source.

Shipping Instructions

Normally the source block, associated source parts and the filament should be shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage during shipment.

All the mass spectrometer sources listed have been repaired by S.I.S. If your mass spectrometer source is not listed below, it can still be repaired by S.I.S. A copy of your source assembly/disassembly schematic from your mass spec manual should be sent in with your source.

Send your source with old filament(s) attached, along with your purchase order to:

     Adaptas Scientific Instrument Services
     9 Second Street
     Palmer, MA   01069
         Attn:  Source Repair - Rush

Related Products
Popular Items also Purchased
  • Electron Multipliers, DeTech 2300 Multipliers for Agilent 5975/5973/597X/1100Electron Multipliers, DeTech 2300 Multipliers for Agilent 5975/5973/597X/1100
    Get a DeTech 2300 Electron Multiplier here. Used in Agilent 5975 MSD (without TAD)/5973/5972/5971/5970/1100 LC-MSD mass spectrometers and backed by a 100% no-nonsense warranty. Developed by Detector Technology, Inc.
  • DeTech 333 Electron Multiplier for UTI/MKS 100C RGADeTech 333 Electron Multiplier for UTI/MKS 100C RGA
    For instruments: UTI/MKS 100C RGA
  • Agilent (Hewlett Packard) 5971 Transfer Line TipAgilent (Hewlett Packard) 5971 Transfer Line Tip
    This new design eliminates any Inlet metal contact with the sample, the capillary column protrudes slightly through the end of the tip directly into the source.
  • Agilent/HP 5973 Source HeaterAgilent/HP 5973 Source Heater
    SIS offers a direct replacement for Agilent p/n G1099-60104. Same performance at a fraction of the cost
  • SNOOP®SNOOP®
    SNOOP is recommended for use in leak testing any pressurized gas system such as air, argon, nitrogen, helium, etc.