Beware of recent phishing e-mails. Use our official contact addresses only.
413-284-9975
Adaptas

SGE HT5 GC Capillary Columns

Catalog D10
Home

Description

5% Phenyl (equiv.) Polycarborane-siloxane
Unique high temperature phase suited for simulated distillation and other petroleum applications. This column is the highest temperature column available with a maximum temperature up to 480 °C (aluminum clad type).

  • highest temperature column in the world (480 °C)
  • ideal for simulated distillation applications (petroleum industry)
  • no equivalents - unique, high temperature phase
GC Capillary Column, SGE, HT5
Part No. ID (mm)Length (m)df (um)Temp Range (C) Quantity
In Stock
Price
EA
Order
Polyimide Clad
054631 Polyimide Clad
0.22120.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054632 Polyimide Clad
0.22250.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054633 Polyimide Clad
0.25150.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054634 Polyimide Clad
0.25300.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054641 Polyimide Clad
0.32120.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054667 Polyimide Clad
0.32150.5010 to 380/400 DISCONTINUED------
054642 Polyimide Clad
0.32250.1010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054668 Polyimide Clad
0.32300.5010 to 380/400 DISCONTINUED------
054655 Polyimide Clad
0.5360.1010 to 380/400 DISCONTINUED------
054657 Polyimide Clad
0.53120.1510 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054670 Polyimide Clad
0.53100.5010 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054658 Polyimide Clad
0.53250.1510 to 380/400 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054672 Polyimide Clad
0.53300.5010 to 380/400 DISCONTINUED------
Aluminum Clad
054635 Aluminum Clad
0.22120.1010 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054636 Aluminum Clad
0.22250.1010 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054651 Aluminum Clad
0.32120.1010 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054652 Aluminum Clad
0.32250.1010 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054673 Aluminum Clad
0.5350.07510 to 460/480 DISCONTINUED------
054661 Aluminum Clad
0.5360.1010 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054662 Aluminum Clad
0.53120.1510 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
054665 Aluminum Clad
0.53250.1510 to 460/480 DISCONTINUED ---3 or more: 5% off; 10 or more: 7% off.---
Popular Items also Purchased
  • GCQ Probe and Probe InletGCQ Probe and Probe Inlet
    GCQ Probe and Probe Inlet
  • Direct Insertion Probe for HP MS with ControllerDirect Insertion Probe for HP MS with Controller
    A ½ inch probe inlet, provides the user with greater flexibility and much faster ramp rates than the standard HP DIP probe.
  • SIS Flared Vials - 10 mmSIS Flared Vials - 10 mm
    SIS Flared Vials - 10 mm
  • High Temperature Direct Probe for HP and Finnigan MSHigh Temperature Direct Probe for HP and Finnigan MS
    The probes can be used from ambient temperature up to 800 degrees C with ballistic temperature ramp of over 700 degrees C/min.
  • Agilent Autosampler SyringesAgilent Autosampler Syringes
    A comprehensive range of syringes for GC autosamplers is available.
  • Tenax® TA Adsorbent ResinTenax® TA Adsorbent Resin
    Tenax® TA is a porous polymer resin based on 2.6-diphenylene oxide.
  • Varian 800 Thermocouple vacuum gauge controlVarian 800 Thermocouple vacuum gauge control
    The 800 Series Thermocouple Vacuum Gauge Controls are used for repeatable, stable pressure measurement in the 10 -3 Torr to 2 Torr range.
  • SGE eVol® XR Hand-Held Automated Analytical SyringeSGE eVol® XR Hand-Held Automated Analytical Syringe
    eVol couples two precision devices: a digitally controlled electronic drive and an XCHANGE enabled analytical syringe.
  • Gas Tight 10 µL to 500 µL SyringesGas Tight 10 µL to 500 µL Syringes
    Plungers are interchangeable on these syringes.
  • SGE SOLGEL-WAX™ GC Capillary ColumnsSGE SOLGEL-WAX™ GC Capillary Columns
    The world's highest temperature WAX capillary column (300 °C)
  • SGE Graphitized Vespel® FerrulesSGE Graphitized Vespel® Ferrules
    Vespel® ferrules contain 15% graphite and are ideal for glass and fused silica capillary columns.