Beware of recent phishing e-mails. Use our official contact addresses only.
413-284-9975
Adaptas

Bayard-Alpert Ionization Gauge Controllers

Home
Bayard-Alpert Ion Gauge Controllers
Hover over image to zoom

Description

The Granville-Phillips Model 330 Ionization Gauge Controller is reliable, easy to operate, easy to service and moderately priced. The 330 with switchable, variable emission currents provides the advantage of long filament life, excellent immunity to electrical noise and easily read pressure display.

Bayard-Alpert style gauges have become the standard for accurate measurement of vacuum in mass spectrometers. In some instances, a mass spectrometer may be shipped without a vacuum gauge since it is an optional accessory (such as in the Hewlett Packard 5971 Mass Spectrometer). The mass spec user can easily add the controller at a cost significantly less than purchasing directly from the mass spectrometer manufacturer.

Often the user may want to add additional gauges to better visualize the operation of the mass spectrometer. On magnetic sector instruments or other mass spectrometers where the source and analyzer are differentially pumped, two ion gauge controllers would be advantageous to separately monitor the vacuum in both the source and at the analyzer (multiplier section). This will enable the quick diagnosis of pumping and vacuum problems for optimum instrument performance and maximum electron multiplier life.

An Ion Gauge Controller can easily be added to the Hewlett Packard 5971 mass spec as shown on the right, by inserting the Ion Gauge Adaptor between the NW25 flange on the mass spec and solenoid valve/calibration vial. The Ion Gauge Adaptor contains NW25 flanges on both ends to clamp into the H.P. 5971 as shown, and a 3/4" Cajon 'O' Ring fitting to attach the ion gauge tube. Also included with the Ion Gauge Adaptor is one centering ring, and one clamp. A complete set up for the H.P. 5971 as shown would include one of each of (1) Model 330 Ion Gauge Controller, (2) Ion Gauge Adaptor, (3) G75K Ion Gauge Tube and (4) 330-10' cable.

Additional flanges or ion gauge adaptors are described elsewhere in this catalog, or Scientific Instrument Services can custom machine an adaptor to your requirements. If you have special requirements, please call or write with the specifications you require.

Features

An economical, accurate method for measuring vacuum

  • Bayard-Alpert Design
  • Convenient Bench Top Enclosure
  • I2R Degas Standard
  • 1 x 10-9 to 1 x 10-1 Torr Range

Model 330 Ion Gauge Controller Ion Gauge Tube & Adaptor installed in a HP 5971 GC/MSD

Specs

Display Green LED Digital
Pressure Range 1 x 10-1 to 1 x 10-9 torr
Units torr
Emission Current Controlled, Adjustable from 0.01 - 10.0 mA
Degas I2R: 8V, 10A max.
Weight 10.5 lbs.
Power Input 110V, 100 watts, 60 Hz
Dimensions 9" wide x 3" high x 11" deep.

*A complete system requires purchase of IGC330, one cable, and one tube.

Part No. Description Picture Quantity
In Stock
Price
EA
Order
IGC330 Ion Gauge Controller Model 330 with degas, Bayard Alpert INACTIVE------
330C10 330 10ft cable DISCONTINUED------
330C25 330 25ft Cable INACTIVE------
G75K ION GAUGE TUBE 3/4" KOVAR HP #09600376 ---.. 0Standard lead-time for non-stock items is approximately two weeks depending on the item. $224.00
Qty
G75P Ion Gauge Tube, 3/4 in Pyrex Iridium thumbnail 0Standard lead-time for non-stock items is approximately two weeks depending on the item. $219.00
Qty
HP71A Ion Gauge Adaptor DISCONTINUED------
Popular Items also Purchased
  • Agilent/HP MS 5970 MSD® and 599X Series FilamentAgilent/HP MS 5970 MSD® and 599X Series Filament
    New filaments for your Agilent 5970 MSD.
  • PTFE Ferrules for Ion Gauge TubesPTFE Ferrules for Ion Gauge Tubes
    They are available in two compositions, PTFE and Glass filled PTFE.
  • Agilent (Hewlett Packard) Mass Spec Ion Gauge TubesAgilent (Hewlett Packard) Mass Spec Ion Gauge Tubes
    Our standard G75K Bayard-Alpert ion gauge tube will fit all models of HP mass specs except the HP5989 MS Engine.
  • PTFE, Glass Filled PTFE Ferrule for Ion Gauge TubesPTFE, Glass Filled PTFE Ferrule for Ion Gauge Tubes
    These 3/4" PTFE Ferrules are used to install Ion Gauge Tubes.
  • Agilent/HP 5971 Bayard Alpert Vacuum Measurement SystemAgilent/HP 5971 Bayard Alpert Vacuum Measurement System
    The vacuum measurement system to monitor the source pressure is optional for the 5971.
  • Inland 45 Mechanical Pump OilInland 45 Mechanical Pump Oil
    Inland 45 is the highest quality rough pump oil you can use for your mass spectrometer.
  • Santovac 5P Ultra and polyphenyl ether vacuum pump fluidSantovac 5P Ultra and polyphenyl ether vacuum pump fluid
    Santovac 5P Ultra has the same properties of Santovac 5 but guarantees minimal amounts of the 3 and 4 ring polyphenyl ethers; less than .02% and .1% respectively and for ultra-clean applications such as mass spectrometry.
  • Granville-Phillips Vacuum Gauge ControllerGranville-Phillips Vacuum Gauge Controller
    Granville-Phillips 340 Vacuum Gauge Controller (VGC) measures pressure from less than 1 x 10-9 Torr to atmosphere, utilizing an ionization gauge and two Convectron gauges.
  • Convectron Series 275 Vacuum GaugeConvectron Series 275 Vacuum Gauge
    The Granville Philips Convectron Gauge tube used on the 5971 and 5972 mass spectrometers is available from S.I.S. This is a direct replacement for the HP original and screws into the fitting shown above.
  • Ion Gauge Tubes, Bayard-Alpert TypeIon Gauge Tubes, Bayard-Alpert Type
    Bayard-Alpert Design and Dual Tungsten or Burn-out Resistant Iridium
  • Electron Multipliers, DeTech 2300 Multipliers for Agilent 5975/5973/597X/1100Electron Multipliers, DeTech 2300 Multipliers for Agilent 5975/5973/597X/1100
    Get a DeTech 2300 Electron Multiplier here. Used in Agilent 5975 MSD (without TAD)/5973/5972/5971/5970/1100 LC-MSD mass spectrometers and backed by a 100% no-nonsense warranty. Developed by Detector Technology, Inc.