908-788-5550

ValcoBond® VB-35 GC Capillary Columns by VICI

ValcoBond VB-35 (35-Phenyl)-methylpolysiloxane GC Capillary Columns
Hover over image to zoom

Description

(35-Phenyl)-methylpolysiloxane

A unique automated process allows VICI to manufacture the highest quality capillary columns at the lowest cost. VICI guarantees their columns will exactly replace or surpass those of the competition while saving you money (up to 35% as compared to the competition). VICI manufactures only MS grade VB-35's, which are sold below standard grade prices.

Features

  • Midpolarity
  • Low bleed
  • MS certified
  • High temperature limits (340/360 °C)
  • Excellent inertness
  • Bonded & cross-linked
  • Solvent rinsable
  • Equivalent to USP Phase G42
  • Guaranteed

Applications

  • Drugs
  • Herbicides
  • PAHs
  • PCBs
  • Pesticides
  • Pharmaceuticals
  • EPA Method 8081A (organochlorine pesticides)

Replaces

DB-35, DB-35ms, HP-35, HP-35MS, AT-35, Rtx-35, Rtx-35MS, Sup-Herb, MDN-35, BP-35, 007-11 or ZB-35.

GC Capillary Column, ValcoBond, VB-35, Temp Range (C)=50 to 340/360
Part No. ID (mm)Length (m)df (um) Stock/
Lead Time
UOM Price Order
CFSC01010010B 0.1100.1 MISSING PART NUMBERCALL
Qty
CFSC01010020B 0.1100.2 MISSING PART NUMBERCALL
Qty
CFSC01010040B 0.1100.4 MISSING PART NUMBERCALL
Qty
CFSC02010010B 0.1200.1 MISSING PART NUMBERCALL
Qty
CFSC02010020B 0.1200.2 MISSING PART NUMBERCALL
Qty
CFSC02010040B 0.1200.4 MISSING PART NUMBERCALL
Qty
CFSC01018018B 0.18100.18 MISSING PART NUMBERCALL
Qty
CFSC01018040B 0.18100.4 MISSING PART NUMBERCALL
Qty
CFSC02018018B 0.18200.18 MISSING PART NUMBERCALL
Qty
CFSC02018040B 0.18200.4 MISSING PART NUMBERCALL
Qty
CFSC04018018B 0.18400.18 MISSING PART NUMBERCALL
Qty
CFSC04018040B 0.18400.4 MISSING PART NUMBERCALL
Qty
CFSC03025025B 0.25300.25 INACTIVEEA------
CFSC03025050B 0.25300.5 MISSING PART NUMBERCALL
Qty
CFSC03032025B 0.32300.25 MISSING PART NUMBERCALL
Qty
CFSC06032025B 0.32600.25 MISSING PART NUMBERCALL
Qty
CFSC01553100B 0.53151 MISSING PART NUMBERCALL
Qty
CFSC03053050B 0.53300.5 MISSING PART NUMBERCALL
Qty
CFSC03053100B 0.53301 MISSING PART NUMBERCALL
Qty
VICI® and ValcoBond® are registered trademarks of Valco Instruments Co. Inc. (VICI) and VICI AG.
Popular Items also Purchased
  • ValcoBond VB-5 (5%-Phenyl)-methylpolysiloxane GC Capillary ColumnsValcoBond VB-5 (5%-Phenyl)-methylpolysiloxane GC Capillary Columns
    Features: Nonpolar Low bleed MS certified High temperature limits (360/370 °C) Excellent inertness Bonded & cross-linked Solvent rinsable Equivalent to USP Phase G27 Guaranteed