- Heaters/Source
- ▶
- Agilent Heaters and SensorsMass Spectrometry, Scientific Supplies & ManufacturingScientific Instrument Services 5973 Source Heater Tamper Resistant Allen Wrench 5973/5975 Quad Sensor 5985 Source Heater Assembly Agilent Interface Heater Assembly 5971 Transfer Line PRT 5971 Interface Heater
- ▶
- Mass Spectrometry - Thermo Finnigan MS RepairThermo/Finnigan Part Number Cross Reference Filament Repair Source Cleaning Thermo GCQ/DSQ & DSQII Source Heater Repair Finnigan MAT 4000 Baffle Repair Thermo/Finnigan MAT 4000 and 4500 Solid Inlet Valve Bellows Assembly Thermo/Finnigan MAT Ceramic Insulator Cleaning C.I. Reagent Gas Line Repair Thermo/Finnigan MAT 4500/4600 Collector Repair & Cleaning Thermo/Finnigan MAT OWA Collector Cleaning 01504-60020 Thermo/Finnigan MAT/Varian MAT, New and Repaired Compression Stamps Thermo/Finnigan MAT Injection Port Repair Thermo/Finnigan MAT Vacuum Flange Repairs Thermo/Finnigan MAT 3200 Heater Repair or New Thermo 5100 Source Heater Thermo 4500/4600/TSQ Source Heaters Thermo/Finnigan MAT Source Ion Volume Insert Cleaning Thermo/Finnigan MAT OWA/3000 Ion Volume Repair Glass Jet Separator Repair and Cleaning Thermo/Finnigan MAT PRT Lead Repair Thermo/Finnigan MAT Connecting Lead Repair Thermo/Finnigan MAT Lead Repair Thermo/Finnigan MAT Lens Heater Repair or New Thermo/Finnigan MAT 4000 Lens Plate Repair Thermo/Finnigan MAT Mass Spectrometer Probe Repairs Separator Divert Assembly Repair Thermo/Finnigan MAT 4000 Source Plate Repair Thermo/Finnigan MAT 3200 Elbow Assembly Repair Thermo/Finnigan MAT 4000 (#40006-60470)
Thermo/Finnigan MAT 4500 (#42000-60004)
GLT Elbow Assembly Repair Thermo/Finnigan MAT 5100 GLT Repair on Elbow Assembly - Agilent/HP - MS - Repair Service
- ▶
- Source Cleaning
- ▶
- Source Cleaning (This Page)
4500/TSQ/SSQ 700/7000
Thermo/Finnigan 4500/TSQ/SSQ700/7000 source cleaning by Scientific Instrument Services.. We can expertly clean and service most models of mass spectrometer sources including filament repair.1020/OWA
Thermo/Finnigan 1020/OWA source cleaning by Scientific Instrument Services.. We can expertly clean and service most models of mass spectrometer sources including filament repair.Delta
Thermo Delta source cleaning by Scientific Instrument Services.. We can expertly clean and service most models of mass spectrometer sources including filament repair.TRACE
Thermo Trace source cleaning by Scientific Instrument Services.. We can expertly clean and service most models of mass spectrometer sources including filament repair.GCQ
Scientific Instrument Services provides a mass spectrometer source cleaning service. We can expertly clean and service most models of mass spectrometer sources including filament repair. Fast turn-around of repairs251
Scientific Instrument Services provides a mass spectrometer source cleaning service. We can expertly clean and service most models of mass spectrometer sources including filament repair. Fast turn-around of repairs3200/5100
Scientific Instrument Services provides a mass spectrometer source cleaning service. We can expertly clean and service most models of mass spectrometer sources including filament repair. Fast turn-around of repairsDSQ/TSQ
Scientific Instrument Services provides a mass spectrometer source cleaning service. We can expertly clean and service most models of mass spectrometer sources including filament repair. Fast turn-around of repairsMAT 253
Scientific Instrument Services provides a mass spectrometer source cleaning service. We can expertly clean and service most models of mass spectrometer sources including filament repair. Fast turn-around of repairs
Description
Mass Spectrometer Source Cleaning
- Expert cleaning & repair of mass spec sources
- Filaments repaired and accurately aligned on mass spec source
- Fast turn-around of your sources for repair
This is NOT an exchange program - The same source that we receive from you is cleaned and repaired and then sent back to you - ready to install into your mass spectrometer.
Scientific Instrument Services now offers a service of mass spectrometer source cleaning. We can clean and service most models of mass spectrometer sources many of which are listed. If your source is not listed please contact us. For sources not listed below please include a copy of the manufacturers assembly instructions and schematic of the source assembly when the parts are sent in for repair.
Cleaning Procedures
The source cleaning article describes in detail the steps and equipment used in the cleaning and repair of all the MS sources that we service at SIS.
Source cleaning begins with the complete disassembly of the source. The metal parts are cleaned and polished, then washed with solvents. The parts are then thoroughly washed in our high temperature ultrasonic cleaner using high purity water and then dried. Finally the metal parts are baked out.
All ceramic insulators are sandblasted, followed by solvent washing and a high temperature bake-out. If broken, most of these ceramics can be replace at no extra cost, with the exception of those with a cost of $50.00 or more. Vespel® insulators are washed and baked out with the same procedures used for the metal parts described above.
If old filaments are included with the source, they are cleaned and repaired using our standard filament cleaning and repair procedures. The filaments are repaired using the standard original filament material used in the original manufacture of the filament. For a complete description of this repair service see the section on Mass Spectrometer Filament Repair and Manufacture.
Not included in the source repairs are the replacement of the filaments, collectors, heaters, screws or other missing parts. If these parts need to be replaced, this may delay return delivery until we can obtain replacement parts from the manufacturer and additional charges may be incurred. If the source heaters are sent in with the source, additional charges will be incurred if these items are damaged and need additional repairs or replacement.
After all parts have been repaired, cleaned and baked out, the source is reassembled in a clean environment in a laminar flow hood. The filament is reinstalled and accurately aligned over the ion source entrance using an optical video microscope system.. The source is checked for resistance leaks due to bad or cracked insulators followed by a thorough visual inspection.
Your source is now ready for installation into your mass spectrometer.
If your source is not listed, it can still be repaired and cleaned by S.I.S. A copy of your source assembly/disassembly schematic from your mass spec manual should be sent in with your source.
Shipping Instructions
Normally the source block, associated source parts and the filament should be shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage during shipment.
All the mass spectrometer sources listed have been repaired by S.I.S. If your mass spectrometer source is not listed below, it can still be repaired by S.I.S. A copy of your source assembly/disassembly schematic from your mass spec manual should be sent in with your source.
Send your source with old filament(s) attached, along with your purchase order to:
Adaptas Scientific Instrument Services
9 Second Street
Palmer, MA 01069
Attn: Source Repair - Rush