Beware of recent phishing e-mails. Use our official contact addresses only.
413-284-9975
Adaptas

MALDI-TOF Supplies for Bruker Shimadzu JEOL

MALDI-TOF Supplies for Bruker Shimadzu JEOL
Hover over image to zoom

Description

A line of Hudson Surface Technology cost-effective, high-performance tools for MALDI-TOF (Matrix Assisted Laser Desorption Ionization - Time of Flight) Mass Spectrometry and proteomics. Get better results, in less time, at less cost and greater convenience with HST products.

μFocus technology is at the heart of HST's product line for MALDI-TOF MS. Unique, proprietary technology produces thin, disposable, single-use stainless steel targets with hydrophilic islands (μFocus spots) on a hydrophobic surface. The results is precise, concentrated, deposition of sample in precise, well-formed spots.

μFocus targets give you a precisely formed dried droplet spot of predetermined size. You can work with larger (1700-2000 μm) spots and use standard spotting techniques. You can also work with much smaller spots (700-900 μm) that allow you to reduce the amount of matrix used, to maintain optimum matrix to analyte ratio with less concentrated or smaller analyte samples. Many users report 5-10x increases in sensitivity. Because μFocus spots are uniform, you also see improvements in spot-to-spot reproducibility, making quantitative analysis and fingerprint assays more reliable.

Features

µFocus® MALDI Targets
Patterned hydrophobic and hydrophilic surfaces focus sample deposits to predefined spots with predefined sizes.Controlled size deposits reduce matrix demand, increasing ana-alyte/matrix ratios.

  • Sensitivity
  • Productivity
  • Economy
  • High Throughout
  • Imaging

You Get: increased signal/noise and greater instrument sensitivity.

Low-cost manufacturing on thin stainless steel plates translates into high-performance in a economical, single-use target.

You Get: Saving and productivity - more experiments in progress, less time spent cleaning plates, reduced costs for heavy sample traffic.

µFocus MALDI Sample Plates
Hydrophobic & Hydrophilic Patterning
Small, Uniform Matrix Deposition
Reduced Matrix - Increased Analyte Concentration
Single use Pricing - No Ghosting, No Clean up

Part No. SeriesTypeDimSpot SizeThicknesspkg of Picture Quantity
In Stock
UOM Price Order
µFocus
PFS2407000 MALDI-TOF Supplies
Bruker Shimadzu Jeol384 circles114.5x77mm700μm0.3t10thumbnail DISCONTINUEDPK------
PFS2409000 MALDI-TOF Supplies
Bruker Shimadzu Jeol384 circles114.5x77mm900μm0.3t10thumbnail DISCONTINUEDPK------
PFS2420000 MALDI-TOF Supplies
Bruker Shimadzu Jeol384 circles114.5x77mm2000μm0.3t10thumbnail DISCONTINUEDPK------
PFB1107000 MALDI PLATES BRUKER MICROFLEX 96 CIRCLES 700UM 53.8X40.8MM; 10/PK
------------------ DISCONTINUEDPK------
PFB1124000 MALDI PLATES 10/PK BRUKER MICROFLEX 96 CIRCLES 2400UM; 53.8X40.8MM
------------------ DISCONTINUEDPK------
Accessories
HMB0101000 MALDI-TOF Supplies
Bruker Shimadzu JeolBruker Magnetic Holder (6 magnet)124.8x83mm100μm3.0t1thumbnail DISCONTINUEDEA------
HMB0201000 MALDI-TOF Supplies
Bruker Shimadzu JeolBruker Magnetic Holder (9 magnet)124.8x83mm100μm3.0t1thumbnail DISCONTINUEDEA------
HMS0101000 MALDI-TOF Supplies
Bruker Shimadzu JeolShimadzu Magnetic Holder126x78.2mm2.0t1thumbnail DISCONTINUEDEA------
HMJ0101000 MALDI-TOF Supplies
Bruker Shimadzu JeolJEOL Magnetic Holder1thumbnail DISCONTINUEDEA------