The Design of a New Direct Probe Inlet for a Mass Spectrometer

Christopher Baker, John Manura and John Manos

We have designed a new probe inlet for use on a mass spectrometer which incorporates design features to improve the performance of the direct probe technique. Direct probes have been used on mass spectrometers for many years. One of the potential problems with the technique is the design of many of the direct probe inlets. These inlets have seals which wear with use and also in many designs the probe can be removed too far from the inlet causing venting of the mass spectrometer if the user is not careful. The new design has a new type of seal which provides for longer seal life and also has a safety mechanism which minimizes the risk of venting the mass spectrometer when removing the probe from the inlet.

This new probe inlet is designed specifically for use on the Hewleff-Packard 5989 MS Engine, however the inlet could be modified for use on other mass spectrometers. The HP probe inlet uses a graphite seal which has demonstrated limited life due to decreased sealing capability and due to the release of small graphite particles, after repeated use, which could create possible contamination. The new seal design provides for much longer seal life while minimizing contamination due to seal wear. The design utilizes a custom PTFE® and Viton® o-ring seal to provide longer seal life and clean operation. These new seals have been used for over two thousand probe analyses without any problems. The previous inlet required changing of the seals every one or two hundred analyses. The PTFE sealing surface does not release any particles with use therefore reducing the potential for contamination. The new probe inlet also prevents possible venting Gf the mass spectrometer during removal of the probe. A probe quide and stop mechanism will not allow the probe to be removed past the inlet seal until a release is pressed on the inlet. This feature also serves to eliminate damage to DCI probe tips during entrance of the probe into the mass spectrometer.

This paper will detail the new probe inlet design and demonstrate the improved performance on a Hewlett-Packard mass spectrometer.

Viton® is a registered trademark of DuPont Dow Elastomers

back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.