Micro Cryo-Trap - Ordering Information
New Programmable Micro Cyro-cooling and heating trap for the Cryo-focusing of volatiles and semivolatiles at the head of GC capillary columns. Two models of the Micro Cryo-Trap are now available. The Model 971 is designed for liquid CO2 use only for cryo-trapping temperatures down to -70 °C. The Model 981 is designed for Liquid Nitrogen use only for cryo-trapping temperatures down to-180 °C. Each model can maintain any cooling temperature within +/- 3 °C from its minimum temperature up to room temperature. In order to release the trapped volatiles from the GC Cryo-Traps, both models can heat the GC Cryo-Trap at temperatures up to 400 °C at a heating ramp rate in excess of 1200 deg/minute. Most users prefer to use the C02 version of the GC Cryo-Trap (Model 971) due to the ease of handling liquid C02 and for applications where -70 °C is an acceptable lower temperature limit. If lower temperatures are required, then the liquid nitrogen version of the GC Cryo-Trap (Model 981) must be used. The liquid nitrogen delivery lines are larger than the CO2 lines and the liquid nitrogen lines must be insulated. This makes installation somewhat more cumbersome. In addition the Liquid Nitrogen version uses more cooling gas and is slightly more audible. Depending on the make and model of your GC, an installation kit must be ordered separately as described below. First you must decide which model of Cryo-Trap is required for your application; the Model 971 for use with C02, or the Model 981 for use with liquid Nitrogen. Although the Cryo-Trap can be used for both CO2 and LN2, the electronics are not interchangeable for the two systems. You must then select which installation kit is required based on the make and model of your gas chromatograph. Either of the two Micro Cryo-Trap(tm) models will fit the same installation kits listed. Model 971 Micro Cryo-Trap for use with Liquid C02 The Model 971 Micro Cryo-Trap is designed for use with liquid CO2 tanks with a DIP tube. The minimum temperature of cooling is -70 °C. This model comes with the Micro Cryo-Trap, the dual temperature electronics controller, connecting cables and stainless steel connecting line. *Order installation kit below.
Model 981 Micro Cryo-Trap for use with Liquid Nitrogen The Model 981 Micro Cryo-Trap is designed for use with liquid nitrogen tanks (low pressure). The minimum temperature of cooling is -180 deg. C. This model comes with the Micro Cryo Trap, the dual temperature electronics controller, connecting cables and copper connecting line. *Order installation kit below.
Cryo-Trap Installation Packages Depending on the make and model of Gas Chromatograph one of the installation packages must be ordered for the installation of the GC Cryo-Trap. The Cryo-Trap installation kits include relays, mounting hardware, cables and other parts required to mount the Cryo-Trap into the particular model of gas chromatograph.
© 1996-2008 Scientific Instrument Services, Inc.
[Trademarks]
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||