Scientific Instrument Services, Inc.  Supplies and Services for Mass Spectrometers, Gas Chromatographs, and Liquid Chromatographs.

Delayed Extraction and Laser Desorption: Time-lag Focusing and Beyond

ASMS, 1996

Steven Colby, Scientific Instrument Services, 1027 Old York Road, Ringoes, NJ 08551

In the two years since Robert Brown's demonstration that delayed extraction can dramatically improve the mass resolution of MALDI-TOFMS, considerable advances have been made in the field. Yet a number of questions still remain regarding the best approach toward identifying optimal conditions. Is the simple algorithm defined by Wiley and McLaren, sufficient for calculating instrument conditions? If so, why was substantial improvement in resolution not observed by the many expert researchers who combined delayed extraction with MALDI before the work by Dr. Brown? We examine the assumptions and "short cuts" employed by Wiley and McLaren in their calculations and demonstrate how some of these restrict the use of their equation to gas phase ionization. We then show how their approach may be modified to generate an expression more applicable to desorption from a surface. This generalized version of Wiley and McLaren's time-lag focusing equation may be used to identify a good value for the time delay between desorption and ionization. However, it is not guaranteed to give the optimum result. We examine conditions where poor results are to be expected. The equation is also limited because it generates a value for only one of a number of critical instrumental parameters. In order to optimize resolution it is necessary to go "beyond time-lag focusing" and briefly examine methods for optimizing other variables. We conclude that non-optimum values of these parameters were the primary factors that limited the resoltion obtained with time delayed extraction before the ground breaking work of Robert Brown.

back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.