ASMS, 1996
Steven Colby, Scientific Instrument Services, 1027 Old York Road, Ringoes, NJ 08551
In the two years since Robert Brown's demonstration that delayed extraction can dramatically improve the mass resolution of MALDI-TOFMS, considerable advances have been made in the field. Yet a number of questions still remain regarding the best approach toward identifying optimal conditions. Is the simple algorithm defined by Wiley and McLaren, sufficient for calculating instrument conditions? If so, why was substantial improvement in resolution not observed by the many expert researchers who combined delayed extraction with MALDI before the work by Dr. Brown? We examine the assumptions and "short cuts" employed by Wiley and McLaren in their calculations and demonstrate how some of these restrict the use of their equation to gas phase ionization. We then show how their approach may be modified to generate an expression more applicable to desorption from a surface. This generalized version of Wiley and McLaren's time-lag focusing equation may be used to identify a good value for the time delay between desorption and ionization. However, it is not guaranteed to give the optimum result. We examine conditions where poor results are to be expected. The equation is also limited because it generates a value for only one of a number of critical instrumental parameters. In order to optimize resolution it is necessary to go "beyond time-lag focusing" and briefly examine methods for optimizing other variables. We conclude that non-optimum values of these parameters were the primary factors that limited the resoltion obtained with time delayed extraction before the ground breaking work of Robert Brown.
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.