Computer Modeling of Ion Optics in Time-of-Flight mass Spectrometry using SIMION 3D

Steven M. Colby and John J. Manura, Scientific Instrument Services, Inc., 1027 Old York Road, Ringoes, NJ 08551

It has been know for some time that non-ideal grids can be an important factor limiting the resolution of time-of-flight mass spectrometers. It has, however, been difficult to quantify the impact of grids in specific instrument designs. We report the development of a new tool for the simulation of ion scattering at grids. This tool is a accessory for use with the ion optics program SIMION 3D v.6.0. It allows the examination of the effects of grids on instrument resolution and sensitivity. Specific examples are presented illustrating the advantages and disadvantages of specific instrument designs in TOFMS. Opportunities for improvements in resolution and sensitivity are proposed.

The simulation of grid scattering is accomplished through the use of SIMION's user programming interface. Monte-Carlo methods are used to randomly alter the trajectories of ions as they pass through a grid. The probabilities of different angular deflections are based on either analytical calculations of the electric field near the grid surface or detailed simulations of the grid environment. For these calculations the program considers the electric field on each side of the grid as well as the kinetic energy of the ion.

Other pages linking here:
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.