(019P) - Comparison of Septa by Direct Thermal Extraction

Santford V. Overton and John J. Manura, Scientific Instrument Services, Inc., 1027 Old York Road, Ringoes, NJ 08551

Poster Number - 019P

Comparison of Septa by Direct Thermal Extraction Santford V. Overton and John J. Manura, Scientific Instrument Sevices, Inc., 1027 Old York Road, Ringoes, NJ 08551 Poster Number 019P The most common source of contaminants in the GC injection port is the septum. Background or "memory" peaks can originate from both septa bleed as well as from previous samples trapped on the septa. The problem of septa bleed can be minimized by using low bleed high temperature septa which produce the lowest amount of bleed even when used at temperatures up to 300 C. Septa bleed can also be minimized by using a septum purge at all times, even when using the splitless technique. In addition, sample splitting in the split mode will minimize the effect of septum bleed. The purpose of this study is to examine septa from several different manufacturers by a new technique entitled "Direct Thermal Extraction" and determine the optimum type of septa commercially available. This new technique utilizes a thermal desorption apparatus attached to the injection port of a GC/MS system and permits the direct thermal extraction of volatile and semi-volatile organics directly from small sample sizes (mg) without the need for solvent extraction or other sample preparation. The samples are ballistically heated and together with the carrier gas flow through the samples the volatiles are outgassed into the injection port and onto the front of the GC column for subsequent analysis via the GC and/or GC/MS. The volatile organics present in the septa were quantified using matrix spiked deuterated internal standards.

Other pages linking here:
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.