Detection and Indentification of Volatiles in Oil Base Paints by Headspace GC with On Column Cryo-Trapping

John J. Manura, Scientific Instrument Services, 1027 Old York Rd, Ringoes, NJ 08551

Poster Number - 381P

Large headspace gas volumes can be introduced into a capillary GC column for subsequent analysis. This is accomplished via the use of a small on column cryo-trap which permits the concentration and focusing of volatiles at the head of the GC capillary column.

One gram to 0.1 gram sample sizes of oil base paints were weighed into a 10 ml headspace sample vial and sealed. The vials were heated to 90o C and agitated for 10 minutes. Headspace volumes from 0.1 to 5.0 ml were injected into the GC injection port slowly (1.5 ml/min) utilizing the LEAP Headspace autosampler and the volatiles cryo-focused at the front of the GC column at -100o C using the GC Cryo-Trap. After injection was complete the injection port was flushed of all volatiles, the cryo-trap was heated to 200o C to release the trapped organics, and the GC oven was temperature programmed to elute the organics. The resulting peaks were identified via a H.P. 5989A mass spectrometer. A large number of oil base paints from various manufacturers were studied to demonstrate the versatility of the technique for the identification of the volatiles in oil base paints and to show the reproducibility of the technique for use as a quality control technique. Each of the paints studied produced characteristic fingerprints of more than 50 peaks. The technique has proven useful for the identification of volatile organics in paints, for use as a quality control technique and for the comparison of paints from different manufacturers.

Other pages linking here:
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.