Scientific Instrument Services, Inc.  Supplies and Services for Mass Spectrometers, Gas Chromatographs, and Liquid Chromatographs.

Analytes Using Mass Spectrometry (CRIMS)

Steven M. Colby,1 Jiuwei Teng,2 Yohannes Teffera,2 John J. Manura,1 and Fred Abramson2, 1Scientific Instrument Services, 1027 Old York Road, Ringoes NJ 08551. 2Dept. of Pharmacology, The George Washington University, 2300 Eye Street, NW, Washington, DC 20037.

The Chemical Reaction Interface Mass Spectrometer (CRIMS) is intended to facilitate the use of nonradioisotopic labeling1,2. Not only are radioisotopes expensive and difficult to use, but they cannot be employed in some applications, such as the analysis of drug metabolism in children. CRIMS involves the atomization of sample in a microwave-induced plasma followed by recombination with a reactant gas. Isotopic abundance of the analyte can be measured by monitoring the masses of simple products. For example, the masses of CO2, NO, and HCl provide reliable indications of the carbon-13, nitrogen-15, and chlorine content in the original molecule.

We report the development of a new CRIMS interface capable of accepting either gas chromatographic effluent or the desolvated output of a liquid chromatograph. The microwave cavity is designed to be inexpensive and compatible with a variety of commercially available mass spectrometers. The new cavity incorporates improved design and surface conduction that results in a more stable discharge. We will characterize the results of all design improvements and report experimental examples intended to demonstrate the versatility of the new interface. The compatibility of the interface with several liquid chromatographic desolvation techniques will also be explored.

References:

  1. Abramson, F.; CRIMS: Chemical Reaction Interface Mass Spectrometry, Mass Spectrom. Rev. 1994, 13, 341-356.
  2. Song, H., and Abramson, F. P.; Nitrogen trifluoride: A new reactant gas in CRIMS (Chemical Reaction Interface Mass Spectrometry) for detection of phosphorus, deuterium, chlorine, and sulfur. J. Am. Soc. Mass Spectrom. 1995, 6, 421-427.
Other pages linking here:
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    IFC75PP210 
    Web Description:
    --- 
    Internal Description:
    PROTEOPEP II COLUMN; REPLACED BY IF75100H002 
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    DISCONTINUED--NO REPLACEMENT RECORDED
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    E50 
  • catalog E50
    New Objective IntegraFrit Columns • • • • • IntegraFrit Columns Reduce tailing and achieve maximum sensitivity L ike PicoFrit columns, IntegraFrit columns are fabricated from 360 µm OD, polyimide-coated, fused-silica tubing, but without a tip. The frit end of the fused-silica column has been polished flat to ...
    /catalog/08/E50
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.