Beware of recent phishing e-mails. Use our official contact addresses only.
413-284-9975
Adaptas

Cryo-Trap™ for the AutoDesorb™ System (Catalog C23)

Home
Cryo-Trap™ for the AutoDesorb™ System (Catalog C23)
Hover over image to zoom
SIS Print Catalog     Page Number: Zoom: [PDF icon Printable PDF]
[C1: Thermal Desorption]
Ordering: Click part number to add to shopping cart or request a quote for your Local Dealer.
background image

C23

Cryo-Trap for the AutoDesorb

System

FAX: 908-806-6631

www.sisweb.com

Trap compounds in the GC oven at the head of

the GC column

For use with the SIS AutoDesorb System Only

For use on the Agilent 7890, 6890 and 5890 GC &

Thermo Trace GC

Set up and controlled by a PC Window

Trap can be used with either LN

2

or CO

2

CO

2

cools to -70°C

LN

2

cools to -180°C

Designed for 0.2, 0.25 and 0.32mm capillary columns

Mounts inside the GC oven under injection port

Does not attach to the injection port - no heat draw

Rapid heating up to 400°C at > 400°C per minute

T

he AutoDesorb Cryo-Trap was designed to operate inside

the GC oven for the trapping of volatiles at the front of the

GC column much like the previous models of the Cryo-

Traps that SIS has produced in the past 5 years. The Cryo-Trap con-

sists of a 2.0" long cooling/heating chamber. In the center of the

chamber is a small stainless steel capillary through which the capil-

lary column freely passes. Around the stainless steel capillary tube

a heating coil is wound to provide for the rapid heating of the capil-

lary tube and capillary column. A Thermocouple provides accurate

measurement of both the cooling and heating temperatures.

The same Cryo-trap can be used with either LN

2

or CO

2

.

There

is no need to purchase separate traps or electronics controllers.

Just select the appropriate valve (CO

2

or LN

2

) kit below depending

on the cooling gas you will be using, or if you prefer purchase both

valves to enable the use of the Cryo-Trap with both types of gases.

CO

2

will enable cooling of the Cryo-Trap down to -70° C and LN

will

enable cooling down to -180°C. The AutoDesorb software will detect

the type of valve which is plugged into the controller and control its

operation automatically.

The Cryo-Trap is controlled and operated via the PC software

and electronics console of the AutoDesorb system.

A PC window

is

used to set the cooling and heating temperatures and times, and the

PC window

monitors and plots the actual Cryo-Trap temperatures

during the sample analysis.

The Cryo-Trap was developed specific to the Agilent 7890, 6890

(also Agilent 5890) GC.

It uses a new mount which attaches to the

top of the oven wall around the GC injection port, but the trap or its

mount do not physically touch the injection port.

Therefore there is

no heat drain from the injection port which would impede the GC

Injection port operation.

The 2.0" trap can be used on 0.2, 0.25 and

0.32 mm I.D. capillary columns, and can also be used on megabore

columns or guard columns (0.53mm) provided that the column flow

does not exceed 5.0 ml/minute.

2" Cryo-Trap designed for use with the SIS AutoDesorb System

2" Cryo-Trap for the AutoDesorb System

AutoDesorb™ PC window to setup and monitor

Cryo-Trap Temperatures

Part No.

Description

976000 Part #976000—Click for details
Current Price: $2243.75
Unit of Measure: EA
Est. Ship Weight=3 lbs
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.

Cryo-Trap for the AutoDesorb™

976020 Part #976020—Click for details
Current Price: $556.25
Unit of Measure: EA
Est. Ship Weight=3 lbs
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.

LN2 Valve Kit for the Cryo-Trap

includes LN2 valve and tubing

976010 Part #976010—Click for details
Current Price: $556.25
Unit of Measure: EA
Est. Ship Weight=5 lbs
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.

CO2 Valve Kit

for the Cryo-Trap

includes CO2 Valve, fitting and tubing

No additional installation kits required for the Agilent GC’s.

Nearby (Previous/Next) Catalog Pages
Popular Items also Purchased
  • SIS AutoDesorb® Thermal Desorption SystemSIS AutoDesorb® Thermal Desorption System
    The SIS AutoDesorb® 12-sample Short Path Thermal Desorption System, for the analysis of volatiles and semi-volatiles by GC and GC/MS systems.
  • SIS 2-Inch CryoTrap for the AutoDesorb SystemSIS 2-Inch CryoTrap for the AutoDesorb System
    CryoTrap for the AutoDesorb System
  • 24 Tube Conditioning Oven for Thermal Desorption Tubes24 Tube Conditioning Oven for Thermal Desorption Tubes
    This 24 tube conditioning oven is used for batch flow conditioning of both empty and packed Silco Coated SS desorption tubes as well as for the flow conditioning of the desorption tube needles.
  • Purge and Trap Stainless Steel Purge HeadsPurge and Trap Stainless Steel Purge Heads
    The top fitting of both purge heads consists of a 1/16" fitting for the attachment of the sparging needle followed by needle adaptor to seal the needle in place and provide for the attachment of the purging gas line.
  • Thermal Desorption Sample LoaderThermal Desorption Sample Loader
    This device is used to inject or load liquid samples directly into the S.I.S. Thermal Desorption Tubes, forcing the syringe contents onto the adsorbent resins in the desorption tube without any loss of sample due to back evaporation.
  • Short Path Thermal Desorption Accessories Supply KitShort Path Thermal Desorption Accessories Supply Kit
    When ordering the Short Path Thermal Desorption System, a wide range of systems and accessories are available depending on the application requirements of the user.
  • Seals for SIS Thermal Desorption TubesSeals for SIS Thermal Desorption Tubes
    Seals are utilized in a variety of locations in the Short Path Thermal Desorption Unit.