ValcoBond® VB-210 GC Capillary Columns
VICI Gig Harbor Group, Inc.
(50%-Trifluoropropyl)-methylpolysiloxane
|
Features:
- MS certified
- High temperature limits (320/340 °C)
- High polarity
- Low bleed
- Excellent inertness
- Bonded & cross-linked
- Solvent rinsable
- Equivalent to USP Phase G6
- Guaranteed
|
Primary Applications:
|
Replaces
DB-210,
HP-210, and SP-2401.
|
The VB-210 exhibits an upper temperature limit up to 80°C higher than
the competition while maintaining low bleed characteristics! A unique automated
process allows VICI to manufacture the highest quality capillary columns
at the lowest cost. VICI guarantees their columns will exactly replace
or surpass those of the competition while saving you money (up to 35%
as compared to the competition).
|
GC Capillary Column, ValcoBond, VB-210, Temp Range (C)=40 to 320/340 |
| CFSJ01010010A |
0.1 | 10 | 0.1 | EA |
2 |
0(#) | $236.00 |
|
| CFSJ01018018A |
0.18 | 10 | 0.18 | PK |
2 |
0(#) | $172.00 |
|
| CFSJ02018018A |
0.18 | 20 | 0.18 | EA |
2 |
0(#) | $289.00 |
|
| CFSJ04018018A |
0.18 | 40 | 0.18 | EA |
2 |
0(#) | $499.00 |
|
| CFSJ01525025A |
0.25 | 15 | 0.25 | EA |
2 |
0(#) | $194.00 |
|
| CFSJ01525050A |
0.25 | 15 | 0.5 | EA |
2 |
0(#) | $194.00 |
|
| CFSJ03025025A |
0.25 | 30 | 0.25 | EA |
2 |
0(#) | $326.00 |
|
| CFSJ03025050A |
0.25 | 30 | 0.5 | EA |
2 |
0(#) | $326.00 |
|
| CFSJ06025025A |
0.25 | 60 | 0.25 | EA |
2 |
0(#) | $593.00 |
|
| CFSJ01532025A |
0.32 | 15 | 0.25 | EA |
2 |
0(#) | $221.00 |
|
| CFSJ01532050A |
0.32 | 15 | 0.5 | EA |
2 |
0(#) | $221.00 |
|
| CFSJ03032015A |
0.32 | 30 | 0.15 | EA |
2 |
0(#) | $357.00 |
|
| CFSJ03032025A |
0.32 | 30 | 0.25 | EA |
2 |
0(#) | $357.00 |
|
| CFSJ03032050A |
0.32 | 30 | 0.5 | EA |
2 |
0(#) | $357.00 |
|
| CFSJ06032025A |
0.32 | 60 | 0.25 | EA |
2 |
0(#) | $641.00 |
|
| CFSJ06032050A |
0.32 | 60 | 0.5 | EA |
2 |
0(#) | $641.00 |
|
| CFSJ01553100A |
0.53 | 15 | 1 | EA |
2 |
0(#) | $231.00 |
|
| CFSJ03053100A |
0.53 | 30 | 1 | EA |
2 |
0(#) | $394.00 |
|
|
(#) Standard lead-time for out-of-stock items is approximately two weeks. |
Ordering information.
International (non-US) prices available through your local dealer.
|
VICI® and ValcoBond® are registered trademarks of
Valco Instruments Co. Inc. (VICI) and VICI AG.