70% Cyanopropyl Polysilphenylene-siloxane
A MS-Premium, low bleed column with a maximum temperature up to
260 °C. Polarity has been designed for Fatty Acid Methyl ester (FAME)
analysis.
Suitable replacement for: CP-Sil88, DB-23, HP-23, Rtx®-2330, SP-2330, SP-2380, VF-23ms, 007-23, AT-Silar and PE-23.
| GC Capillary Column, SGE, BPX70, Temp Range (C)=50 to 250/260, UOM=EA | |||||||
| Part No. | ID (mm) | Length (m) | df (um) | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|---|
| 054600 | 0.10 | 10 | 0.20 | 2 | 0(#) | $325.00 | |
| 054601 | 0.22 | 12 | 0.25 | 2 | 0(#) | $300.00(*B) | |
| 054602 | 0.22 | 25 | 0.25 | 2 | 0(#) | $520.00(*B) | |
| 054612 | 0.22 | 30 | 0.25 | 2 | 0(#) | $520.00(*B) | |
| 054603 | 0.22 | 50 | 0.25 | 2 | 0(#) | $860.00(*B) | |
| 054613 | 0.22 | 60 | 0.25 | 2 | 0(#) | $860.00(*B) | |
| 054621 | 0.25 | 15 | 0.25 | 2 | 0(#) | $300.00 | |
| 054622 | 0.25 | 30 | 0.25 | 2 | 0(#) | $520.00(*B) | |
| 054623 | 0.25 | 60 | 0.25 | 2 | 0(#) | $860.00(*B) | |
| 054624 | 0.25 | 120 | 0.25 | 2 | 0(#) | $1425.00(*B) | |
| 054605 | 0.32 | 12 | 0.25 | 2 | 0(#) | $320.00(*B) | |
| 054606 | 0.32 | 25 | 0.25 | 2 | 0(#) | $550.00(*B) | |
| 054616 | 0.32 | 30 | 0.25 | 2 | 0(#) | $550.00(*B) | |
| 054607 | 0.32 | 50 | 0.25 | 2 | 0(#) | $910.00(*B) | |
| 054617 | 0.32 | 60 | 0.25 | 2 | 0(#) | $910.00(*B) | |
| 054619 | 0.53 | 15 | 0.50 | 2 | 0(#) | $345.00(*B) | |
| 054610 | 0.53 | 25 | 0.50 | 2 | 0(#) | $600.00(*B) | |
| 054620 | 0.53 | 30 | 0.50 | 2 | 0(#) | $600.00(*B) | |
|
(*_) Marked parts have bulk quantity discount pricing:
Discount code 'B' -- 3 or more: 5% off; 10 or more: 7% off.
| |||||||
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | |||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||||
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| D21 - Fused Silica Tubing | 054600, 054602, 054603, 054616, 054617, 054619, 054620, 054621, 054622, 054623 |
| D7 - SGE Capillary Columns | 054600, 054601, 054602, 054603, 054605, 054606, 054607, 054610, 054612, 054613, 054616, 054617, 054619, 054620, 054621, 054622, 054623, 054624 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.