SGE Capillary Columns

D8

Phone: 908-788-5550

www.sisweb.com

Forte BP225

50% Cyanopropylphenyl Polysiloxane

Useful for the analysis of Fatty Acid Methyl Esters

(FAMEs), carbohydrates, and neutral sterols.

Suitable replacement for: HP-225, DB-225, Rtx-225.

I.D.

Length

Film

Temperature

Part

(mm)

(meter)

Thickness (µm)

Limits (°C)

Number

0.22

25

0.25

40 to 230/260

054352 Part #054352—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

50

0.25

40 to 230/260

054353 Part #054353—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

0.32

25

0.25

40 to 230/260

054358 Part #054358—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

0.53

25

0.50

40 to 230/260

054364 Part #054364—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

Forte BP1

100% Dimethyl Polysiloxane

An industry standard non-polar phase suitable for all routine analysis.

An extremely low bleed phase with a high temperature limit of 360°C.

SGE - Solutions Through Research and Development

SGE’s range of capillary columns is based on leading edge technology designed to offer new heights in analytical performance. The sub-

stitution into the phase

backbone of either a benzene molecule (BPX) or an m-carborane molecule (HT) means the column is protected

from temperature and chemical degradation (bleed) over time. The result is a robust column which can operate routinely at temperatures

40°-50°C higher than that of conventional columns, yet exhibits remarkably low bleed.

I.D.

Length

Film

Part

(mm)

(meter)

Thickness (µm)

Number

0.22

12

0.25

054046 Part #054046—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

12

1.00

054052 Part #054052—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

15

0.25

054049 Part #054049—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

25

0.10

054041 Part #054041—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

25

0.25

054047 Part #054047—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

25

1.00

054053 Part #054053—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

0.25

054050 Part #054050—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

0.25

15

0.25

054043 Part #054043—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

0.25

054044 Part #054044—Click for details
Current Price: $626.90
(3 or more: 5% off; 10 or more: 7% off)
Unit of Measure: EA
Est. Ship Weight=1.5 lbs
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.

30

0.50

054820 Part #054820—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

1.00

054056 Part #054056—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.25

054045 Part #054045—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.50

054812 Part #054812—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

1.00

054815 Part #054815—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

I.D.

Length

Film

Part

(mm)

(meter)

Thickness (µm)

Number

0.32

12

0.25

054058 Part #054058—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

12

0.50

054064 Part #054064—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

12

1.00

054070 Part #054070—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

15

0.25

054061 Part #054061—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

0.25

054062 Part #054062—Click for details
Current Price: $667.90
(3 or more: 5% off; 10 or more: 7% off)
Unit of Measure: EA
Est. Ship Weight=1.5 lbs
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.

30

0.50

054068 Part #054068—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

1.00

054813 Part #054813—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

1.50

054811 Part #054811—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.25

054067 Part #054067—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.50

054069 Part #054069—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

1.00

054810 Part #054810—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

0.53

15

1.00

054089 Part #054089—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

1.00

054090 Part #054090—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.50

054871 Part #054871—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

Similar Phases

CP-Sil 5CB, DB- Petro, DB-1, HP-1, HP-1MS, Petrocol DH, Rtx-1,

SPB-1, SPB-1Sulfur, Ultra-1

Applications

General purpose, hydrocarbons, aromatics, pesticides, phenols,

herbicides, amines, fatty acid, methyl esters, GC/MS applications

Temperature Range Isothermal/temperature programmed

0.1µm - 1.0µm film:

-60°C to 340°C/360°C

>1.0µm film:

-60°C to 280°C/300°C

Features:

Highest Operating Temperatures

Extremely Low Bleed

Excellent Column Inertness

Resistance to Degradation by Chemicals, Air & Water

Fo rt e

BPX90 is the latest development in high per-

formance GC Capillary Columns from SGE. It is a

unique column in that it is both highly polar and has

high thermal stability (280°C). The principal π-π reten-

tion mechanism gives forte BPX90 a unique selectivi-

ty, which allows it to separate compounds that cannot

be resolved using conventional columns. forte BPX90

is an ideal column for fast high polarity separations in

areas such as separation of the cis, trans and posi-

tional isomers of FAMEs, perfumery, petrochemicals,

pesticides, PCBs and aromatics. forte BPX90 is also

an excellent choice for 2D-GC, in combination with

non-polar phases.

Forte BPX90

90% Cyanopropyl Polysilphenylene-siloxane

Similar Phases

Unique to SGE

I.D.

Length

Film

Temperature

Part

(mm)

(meter)

Thickness (µm)

Limits (°C)

Number

0.25

15

0.25

280

054570 Part #054570—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

0.25

280

054580 Part #054580—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.25

280

054590 Part #054590—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

0.32

15

0.50

280

054573 Part #054573—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

30

0.50

280

054583 Part #054583—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

60

0.50

280

054593 Part #054593—Click for details
DISCONTINUED
Unit of Measure: EA
Est. Ship Weight=1.5 lbs

See web for additional selections

Nearby (Previous/Next) Catalog Pages
Popular Items also Purchased
  • SNOOP®SNOOP®
    SNOOP is recommended for use in leak testing any pressurized gas system such as air, argon, nitrogen, helium, etc.
  • Oxiclear™ Disposable Gas PurifierOxiclear™ Disposable Gas Purifier
    The Oxiclear Gas Purifiers are oxygen absorbing gas purifiers with high efficiency and low resistance to gas flow.
  • SGE BP1 GC Capillary ColumnsSGE BP1 GC Capillary Columns
    Capillary Columns - Dimethyl Polysiloxane technology.
  • SGE Ferrules for GCSGE Ferrules for GC
    standard graphite ferrules (for GC applications)
  • Inland 45 Mechanical Pump OilInland 45 Mechanical Pump Oil
    Inland 45 is the highest quality rough pump oil you can use for your mass spectrometer.
  • Thermo/Ferrules for columns and Jets on Finnigan MSThermo/Ferrules for columns and Jets on Finnigan MS
    Ferrules, Jet Separators, and GC column.