- Heaters/Source
- ▶
- Agilent Heaters and SensorsMass Spectrometry, Scientific Supplies & ManufacturingScientific Instrument Services 5973 Source Heater Tamper Resistant Allen Wrench 5973/5975 Quad Sensor 5985 Source Heater Assembly Agilent Interface Heater Assembly 5971 Interface Heater
- ▶
- Probes
- ▶
- Probes for Agilent Mass Spectrometers
- ▶
- Agilent MSD Probe
- Print Catalog
- ▶
-
A. Mass Spectrometer Supplies and Services
Print Catalog B. Supplies for Specific Mass Spectrometers Mass Spectrometer Source Cleaning [A2] Agilent Mass Spectrometer Source Cleaning [A3] Thermo Mass Spectrometer Source Cleaning [A4] VG Mass Spectrometer Source Cleaning [A5] Other Mass Spectrometer Source Cleaning [A6] Filament & Heater Repair [A7] Filament & Heater Repair [A8] Filament & Heater Repair [A9] Filament & Heater Repair [A10] Filament & Heater Repair [A11] Filament & Heater Repair [A12] Filament & Heater Repair [A13] Filament & Heater Repair [A14] Filament & Heater Repair [A15] Filament & Heater Repair [A16] Filament & Heater Repair [A17] Filament & Heater Repair [A18] X-Ray Generator Filament & Heater Repair [A19] New Mass Spec Filaments by SIS™ [A20] New Mass Spec Filaments [A21] New Mass Spec Filaments [A22] New Mass Spec Filaments [A23] New Mass Spec Filaments [A24] Mass Spec Source Heaters [A25] MS Cartridge Heaters [A26] MS Cartridge Heaters [A27] Platinum Resistance Thermometers [A28] Platinum Resistance Thermometers [A29] Heating Tapes [A30] Filament & Heater Material [A31] Filament & Heater Material [A32] Filament & Heater Material [A33] Filament & Heater Material/Heater Coils [A34] Electrical Connectors [A35] DeTech Electron Multipliers [A36] DeTech Electron Multipliers for Thermo Systems [A37] DeTech Electron Multipliers for Agilent Systems [A38] DeTech Electron Multipliers [A39] ? ? ? ETP Electron Multipliers [A43] Electron Multiplier Cross Reference [A44] Electron Multiplier Cross Reference [A45] Electron Multiplier Cross Reference [A46] Electron Multiplier Cross Reference [A47] Direct Insertion Probe for Agilent 5973, 5975 & 5977 [A48] Direct Insertion Probe for Agilent 5973, 5975 & 5977 [A49] ? Direct Probe Sample Vials [A51] Sample Vials & Sample Vial Blocks [A52] Quartz Sample Vials & Pyrolysis [A53] Calibration Compound [A54] Ceramic Cement, Fish Spines & Sapphire Balls [A55] MALDI-TOF Supplies [A56] MALDI-TOF Supplies [A57] Ceramic Tubes [A58] Ceramic Insulators [A59] Ceramic Insulators [A60] Ceramic Insulators [A61] Ceramic Insulators [A62] Micro-Mesh® Cushioned Abrasive Sheets [A63] Micro-Mesh® Cushioned Abrasive Sheets [A64] Micro-Mesh® Cushioned Abrasive Sheets [A65] Micro-Mesh® Kits & Other Products [A66] Instrument Cleaning Supplies [A67] Discontinued [E48] Discontinued [E48] SIMION™ Version 8.1 [A70] SIMION™ Version 8.1 [A71] NIST Mass Spectral Library & Software [A72] NIST Mass Spectral Library & Software [A73] Wiley Mass Spectral Libraries [A74] Wiley Mass Spectral Libraries [A75] Wiley Mass Spectral Libraries [A76]
- ▶
- Catalog Page A48 (This Page)
Direct Insertion Probe for Agilent 5973, 5975 & 5977*
A48
Phone: 908-788-5550
www.sisweb.com
D
irect Probe sample analysis can be accomplished on
the Agilent 5973, 5975 & 5977
MSD with the new Direct
Probe Inlet System from Scientific Instrument Serv-
ices™ .
The probe inlet mounts onto the GC/MS transfer line port and
uses an indexed probe introduction guide to permit the direct inser-
tion and removal of the probe into the MSD source without venting
the MSD or scoring the probe rod. The probe can be either heated
ballistically at ramp rates in excess of 500 degrees per minute or
can be temperature programmed with up to 25 ramp rate levels. The
probe temperatures, ramp rates, hold times, start and stop are all
PC controlled and fully integrated with the Agilent ChemStation™
software. This permits the storage of the probe analysis parameters
in the sample data files and the method files.
The SIS™ probe for the Agilent 5973, 5975 & 5977 MSD is only
1/4" in diameter which enables it to easily slide through the probe
sealing system and into the MSD. It is light in weight and comfort-
ably fits in your hand for ease of use. The probe tip with sample vial
can be heated up to 450°C either ballistically or in the programma-
ble mode. In the ballistic mode it will ramp up to temperature in ex-
cess of 500°C per minute or alternatively it can be used in the
temperature ramp mode which has 25 levels of ramping capabilities
to provide for the ultimate control of probe tip temperature. For cool-
ing the probe, compressed air is used. This permits the cooling of
the probe after sample analysis and before the probe is removed
from the MSD through the vacuum seals. This prevents damage to
the probe inlet vacuum seals.
The probe tip incorporates a small spring to gently hold the sample
vial in place. The probe is designed for using glass flared sample
vials. These flared sample vials permit the efficient introduction of
samples (both solid and liquid) into the sample vials and permit the
easy insertion and removal of the sample vials from the probe tip
without breakage.
*5977 without Extractor Ion Source
Direct Insertion Probe for the Agilent 5973 and 5973, 5975 & 5977 MSD
(w/o extractor source)
System Features:
•
Easy to install - mounts on the GC/MS
inlet port
•
PC window for the control of temperatures
and ramp rates
•
Ballistic ramp rate >500 degrees per minute
•
Up to 25 levels of programmable
temperature ramping
•
Probe PC control software fully integrated
with the Agilent ChemStation™ software
•
Can be used with either the turbo pump or
diffusion pump version of 5973, 5975 & 5977
Complete Direct Probe System mounted on the
Agilent 5973 MSD
Direct Insertion Probe and Probe Inlet System
Probe Tip with sample vial ready for introduction into the MSD
Direct Probe for the Agilent 5973, 5975, & 5977
(w/o extractor source)
- Table of Contents
(Print Catalog)Table of Contents of the Scientific Instrument Services general catalog volume 36. - Print Catalog A. Mass Spectrometer Supplies & Service SIS Vol. 36 catalog Section A - MS Supplies and Services.
- Electron Multiplier Cross Reference
(Catalog A47) - Direct Insertion Probe for Agilent 5973, 5975 & 5977
(Catalog A48) - Direct Insertion Probe for Agilent 5973, 5975 & 5977
(Catalog A49)