Edwards pumps are designed to give long, trouble-free service. However, as with any piece of mechanical equipment, these pumps will give their best performance if they are serviced regularly using the correct spare parts.
The service kits for the popular Edwards pumps are listed below. The "small pump clean and overhaul kits" are intended for strip down, routine maintenance and pump repair. The combination of the clean and overhaul kit with the blade kit gives full-service capability to your pump overhaul. These service kits also include instructions for use of the kits. All kits are designed and manufactured by Edwards to assure the best possible performance from your equipment.
Small Pump Clean & Overhaul Kits
| Small Pump Clean and Overhaul Kit | ||||||
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| A37101131 | for E2M1, E2M1.5, E2M0.7 | KT | 1 | 1 | $245.00 | |
| A34101131 | for E2M2, E1M5, E2M5, E1M8, E2M8 | EA | 1 | 1 | $254.00 | |
| A37001131 | for E2M12 | KT | 1 | 1 | $266.00 | |
| A36301131 | for E2M18 | KT | 1 | 2 | $346.00 | |
| A37301131 | for E2M30 | KT | 1 | 0(#) | $355.00 | |
| A65201131 | for Standard RV Pumps(RV3, RV5, RV8, RV12) | EA | 1 | 5 | $312.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Blade Kits
Note: Blade kits are not complete overhaul kits. These kits only contain the polymer impeller blades. For a complete overhaul kit order the small pump clean & overhaul kits listed above.
| Blade Kit | ||||||
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| A37101132 | for E2M1, E2M0.7, E2M1.5 | EA | 1 | 1 | $166.00 | |
| A36001129 | for E2M2 | KT | 1 | 2 | $205.00 | |
| A34101130 | for E1M5 | KT | 1 | PART NUMBER OUTDATED. New number is A34101129(#) | --- | --- |
| A36101130 | for E2M5 | EA | 3 | PART NUMBER OUTDATED. New number is A36101129(#) | --- | --- |
| A34201130 | for E1M8 | KT | 1 | 0(#) | $163.00 | |
| A36201129 | for E2M8 | KT | 1 | 0(#) | $317.00 | |
| A37001130 | for E2M12 | EA | 3 | PART NUMBER OUTDATED. New number is A37001129(#) | --- | --- |
| A65201130 | for RV3 | KT | 1 | 6 | $154.00 | |
| A65301130 | for RV5 | EA | 1 | 1 | $159.00 | |
| A65401130 | for RV8 | KT | 1 | 0(#) | $203.00 | |
| A65501130 | for RV12 | KT | 1 | 0(#) | $219.00 | |
| A36301020 | for E2M18 | KT | 1 | 0(#) | $457.00 | |
| A37301135 | for E2M30 | EA | 1 | 0(#) | $518.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| F27 - BOC Edwards Rotary Vane Vacuum Pumps | A65201130, A65201131, A65301130 |
| F28 - BOC Edwards Rotary Vane Vacuum Pumps | A65201131, A65401130, A65501130 |
| F29 - BOC Edwards EM Vacuum Pumps | A37101131, A37101132, A65201130, A65201131 |
| F30 - BOC Edwards EM Vacuum Pumps | A36301020, A36301131, A37301131, A37301135 |
| F37 - Vacuum Pump Accessories | A34101131, A34201130, A36001129, A36201129, A36301020, A36301131, A37001131, A37101131, A37101132, A37301131, A37301135, A65201130, A65201131, A65301130, A65401130, A65501130 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.