Scientific Instrument Services, Inc.  Supplies and Services for Mass Spectrometers, Gas Chromatographs, and Liquid Chromatographs.
SIS Catalog Online >> Page Number: [ previous page next page ]
[ Vacuum System Supplies | Index] Zoom: [PDF icon Printable PDF]
Ordering: Click part number to add to shipping cart. Contact your Local Dealer for non-US prices.
background image
Convectron Ionization Gauge Controllers
F6
Scientific Instrument Services, Inc.
Phone: 908-788-5550
www.sisweb.com/catalog/08/F6
•
Wide Pressure Range 10 - 1000 Torr
•
Highly Accurate Convectron Design
•
High Repeatability
•
Fast Response Time
•
RoHS / CE Compliant
S
eries 475 Convectron gauges provide useful pressure
measurement over 7 decades from 10 to 1000 Torr, or
from 1 x 10 mbar to 1000 mbar. This innovation in the
art of vacuum measurement is accomplished with a single gauge
tube and controller. The gauge tube contains a temperature
compensated heat loss sensor which utilizes conduction cooling
to sense pressure at lower pressures. At higher pressures, it
utilizes convection cooling in which gas molecules are circulated
through the gauge tube by gravitational force.
Convectron gauges offer the following advantages relative to
thermocouple gauges:
•
System performance can be monitored continuously
from atmosphere down without pressure blind spots.
•
Purchase of additional controller and gauge tube
models is not necessary if your needs change to
different segments of the range.
•
A much wider range can be covered with one
Convectron gauge than with thermocouple gauges.
•
There is no chance of error that might be caused by
using the wrong gauge tube-controller combination.
One gauge tube fits all controller models.
Their wide useful range, highly predictable performance and
low prices make Convectron gauges an excellent replacement for
conventional thermocouple and Pirani gauges. They also are the
measurement systems to consider in applications where
conventional thermocouple and Pirani gauges have not been
suitable because of limited range, or drift, or slow response.
Pressure in Torr for Air
Series 275 Gauge Specifications
Useful Measuring Range
1 millitorr to 1000 Torr, or 1 x 10
mbar to 1000 mbar, for
N using a single gauge tube and controller.
Digital Readout
Seven decade range indicated by lighted LED’s, automatic
ranging displays correct measuring units at all times.
An easy to read VFO pressure display configurable to use
scientific notation or two ranges (Torr and mTorr, mbar and
10 mbar or kPa and Pa) to provide a continuous measurement
readout from atmosphere to low pressure.
Gauge Tube Mounting
Gauge tube axis must be horizontal to provide accurate
measurement above about 1 Torr (1 mbar). Excessive vibration
can slightly affect readout of digital gauge above about 1 Torr
(1 mbar) because of forced convection effects in the tube.
Gauge Tube
Internal Volume: 40 cc (2.5 cu. in.)
Sensor: Gold plated tungsten.
Stability with Voltage Variation
Pressure reading changes by less than 0.02% of reading per
1% change in line voltage over most of the pressure range.
Gauge Weights
lbs.
kg
Net
3.5
1.6
Controller Dimensions
in.
mm
Front of panel, h., w.
3.81
97
Front of panel, depth
0.75
19
Rear of panel, depth
with connector
8.65
220
Mounting hole, square 3.63
92
Granville - Phillips Model 475 for accurate low vacuum measurement
Fig. 1
Comparison of the range of a single convectron
gauge with the range of typical thermocouple and
Pirani gauges.
Convectron Gauge
Thermocouple Gauge
Pirani Gauge
10
-4
10
-3
10
-2
10
-1
1
10
100
1000
Part No.
Description
475001-AAT Part #475001AAT--Click to order
Current Price: $795.00
Unit of Measure: EA
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.
*
Controller RS232, 2 set points reads Torr
275071 Part #275071--Click to order
Current Price: $195.00
Unit of Measure: EA
Est. Ship Weight=0.25 lbs
Quantity in Stock=3
1/8 NPT Convectron Tube
375006-1 Part #3750061--Click to request quote
DISCONTINUED
Obsolete part number. New number is 4750081. Please call for ordering (1-908-788-5550).
Unit of Measure: EA
Power Supply Wall Mount 115 VAC
375007-3 Part #3750073--Click to request quote
DISCONTINUED
Obsolete part number. New number is 4750083. Please call for ordering (1-908-788-5550).
Unit of Measure: EA
Power Supply, CE Compliant
220 VAC Europe
475112-10 Part #47511210--Click to request quote
Obsolete part number. New number is 47501210. Please call for ordering (1-908-788-5550).
Unit of Measure: EA
10' Cable
*This is the controller only. Purchase cables and tubes separately.
â„¢
-4
â„¢
-4
-4
2
-3
-3
Related information may be found on the following pages of our web site:
PageParts
Convectron Ion gauge controllers, pg F6-7275071
,Granville-Phillips Vacuum Gauge Controller, pg F8275071
Hewlett Packard Convectron Gauge Tube275071
Page Number: [ previous page next page ]
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2010 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Results:
  • Matching part number:
    SIS Part Number:
    1050003 
    Web Description:
    Dry-Ice Cooled Foreline Trap, Ports=NW 25 x 3/4in, A (in)=11 1/16 
    Internal Description:
    FORELINE TRAP-DRY ICE COO;  
    Unit of Measure:
    EA 
    Estimated Ship
    Weight (lbs):
    Status:
    SUPERSEDED BY PART # DIFT25
    Quantity in Stock:
    0 - please call for availability 
    Catalog pages:
    F54, [1] 
  • catalog Dry-Ice & LN2 Cooled Foreline Traps
    Dry-Ice Cooled Foreline Trap D ry-ice and alcohol is all that is needed to cool this cold trap to -75°C, thus trapping most volatile materials. Holds 3 quarts of dry-ice slurry (dry-ice and alcohol). Holding time is approximately 20 hours depending on vacuum through-put. The ...
    /catalog/08/F54
  • catalog Dry-Ice Foreline Trap
    Dry-Ice Cooled Foreline Trap Dry-ice and alcohol is all that is needed to cool this cold trap to -75°C, thus trapping most volatile materials. Holds 3 quarts of dry-ice slurry (dry-ice and alcohol). Holding time is approximately 20 hours depending on vacuum throughput. The cold well ...
    /vacuum/sis/dryicetrap.htm
SIS News
SIS E-Mail Newsletter [23 May 2011]
Notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.