For sampling of volatile and semivolatile organics from large samples at elevated temperatures


Standard Chamber (Complete) and Standard Chamber with heated cover removed.
The Heated Thermal Desorption Sampling Chambers are used to contain large solid matrix samples for the purpose of purging off the volatile and semi-volatile organics at elevated temperatures and then trapping these analytes on thermal desorption tubes packed with a variety of adsorbent resins. The samples collected are then analyzed using the thermal desorption system in conjunction with a GC and/or GC/MS. The chamber shown is 4" in diameter x 4" high and can analyze samples up to 3.0" diameter x 1.5" high. These systems are custom made on order and other chamber sizes can be constructed according to your requirements.
Two models of the 4" Sample Chamber are available - Standard and High Temperature. The Standard Model is constructed using an NW type flange with a PTFE encapsulated sealing ring (max temp 250 degrees C) and a quick disconnect clamp. The High Temperature Model is constructed using a standard Conflat flange with a copper sealing ring (maximum temperature 450 degrees C) and the chamber is clamped using standard 1/4" diameter bolts.
The system shown contains two heaters. Both heaters contain a J type thermocouple for the measurement of the temperature at the heater surface. The system requires two separate temperature controllers one for each of the heater circuits (these must be ordered separately). The interior plate heater is used to directly heat the sample on top of this plate inside the sealed chamber. This heater can be heated up to 800 degrees C. The external heater is used to heat the sample chamber to prevent the condensation of volatiles on the surface of its walls. This heater is also used to heat the chamber to higher temperatures in order to bake it out between samples. The maximum temperature for heating the walls is dependent on the material used to seal the two halves of the sample chamber (Standard Model is 225 degrees C and High Temperature Model is 450 degrees C).
The systems shown contain an adjustable internal purge gas nozzle that can be positioned or replaced with another style to suit the users needs. The purge gas can be adjusted from 0 to 1000 ml/min using a separate gas flow controller (not included).
The system is designed to accept any 1/4" diameter thermal desorption tube including 1/4" glass tubes as well as the SIS GLT thermal desorption tubes. The desorption tube is attached to the top of the chamber using the 1/4" Swagelok fitting with either PTFE or Graphitized Vespel seals.

Theory of Operation of the Desorption Sampling Chamber
Standard 4" TD Sampling Chamber
Features
High Temperature 4" TD Sampling Chamber
Features
| UOM=EA | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| SC400 | SAMPLING CHAMBER 4" DIAMETER LOW TEMP. | 20 | 0(#) | $4500.00 | |
| SC450 | SAMPLING CHAMBER 4" HIGH TEMP. | 20 | 0(#) | $5100.00 | |
| 912000 | Temperature Controller - Model CT101 | 10 | 0(#) | $875.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| C21 - Heated Thermal Desorption Sampling Chambers | 912000, SC400, SC450 |
| C31 - Temperature Controller & Heater Sleeves | 912000 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.