[1]
Photonis 4219 Multiplier (SIS Part #)
For use on instruments:
Perkin Elmer 15-255
Notes: Unmounted
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $--call--,
Order Quantity:
|
|
[2]
Photonis 4727 Multiplier (SIS Part #33865)
For use on instruments:
INFICON/Leybold Auditor II,
Perkin Elmer Q-Mass
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $--call--,
Order Quantity:
|
|
[3]
ETP AF138 Multiplier (SIS Part #14138)
For use on instruments:
Perkin Elmer Ion Trap,
Thermo Finnigan ITD 700,
Thermo Finnigan ITD 800,
Thermo Finnigan ITS 40,
Thermo Finnigan Magnum,
Varian Saturn I,
Varian Saturn II,
Varian Saturn III
|
|
[4]
ETP AF532 Multiplier (SIS Part #14532)
For use on instruments:
INFICON/Leybold Auditor,
Perkin Elmer Q-Mass
|
|
[5]
Detech 21010SL Multiplier (SIS Part #21010SL)
For use on instruments:
Perkin Elmer 15-255
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $748.00,
Order Quantity:
|
|
[6]
Detech 350 Multiplier (SIS Part #350)
For use on instruments:
Perkin Elmer Ion Trap,
Varian Saturn I,
Varian Saturn II,
Varian Saturn III
Notes: Mounted.
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $748.00,
Order Quantity:
|
|
[7]
Detech 414 Multiplier (SIS Part #414A)
For use on instruments:
Perkin Elmer AES-590,
Perkin Elmer AES-548
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $748.00,
Order Quantity:
|
|
[8]
Detech 464 Multiplier (SIS Part #464)
For use on instruments:
Perkin Elmer 5000LS,
Perkin Elmer 5500
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $748.00,
Order Quantity:
|
|
[9]
Detech 473 Multiplier (SIS Part #473)
For use on instruments:
Hitachi RMU-6D,
Perkin Elmer 3010,
Perkin Elmer 10-155,
Perkin Elmer 15-155
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $748.00,
Order Quantity:
|
|
[10]
Photonis 4715 Multiplier (SIS Part #30071)
For use on instruments:
Thermo Finnigan Ion Trap Detector® (ITD),
Thermo Finnigan TSQ® 70 with 20 kV dynode,
Thermo Finnigan TSQ® 700,
Perkin Elmer Ion Trap,
Varian Saturn I,
Varian Saturn II
Notes: Unmounted
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $865.00,
Order Quantity:
|
|
[11]
Photonis 4821G Multiplier (SIS Part #30117)
For use on instruments:
Perkin Elmer 5000LS,
Perkin Elmer 5500
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $865.00,
Order Quantity:
|
|
[12]
Photonis 4831G Multiplier (SIS Part #30129)
For use on instruments:
Perkin Elmer 3025,
Perkin Elmer 3045,
Perkin Elmer 3067,
Perkin Elmer 3500,
Perkin Elmer 3600,
Perkin Elmer 5500,
Perkin Elmer 6000,
Perkin Elmer 6300,
Perkin Elmer 6700,
Perkin Elmer 660,
Perkin Elmer 600,
Perkin Elmer AES-590,
Perkin Elmer AES-548,
Perkin Elmer 25-270 CMA,
Perkin Elmer 15-255,
Omicron CMA
Notes: mounted
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $865.00,
Order Quantity:
|
|
[13]
Photonis 4839 Multiplier (SIS Part #30131)
For use on instruments:
Hitachi RMU-6D,
Perkin Elmer 3010,
Perkin Elmer 10-155,
Perkin Elmer 15-155
Warranty:
Photonis Channeltrons(R) are designed and manufactured to the highest
standards in the world. It is warranted against all defects
in materials and workmanship for one year after installation.
In addition, if you install your Channeltron(R) electron
multiplier and are not completely satisfied with its performance,
return it promptly for replacement or refund.
Online-ordering: $865.00,
Order Quantity:
|
|
[14]
Detech 308 Multiplier (SIS Part #308)
For use on instruments:
INFICON/Leybold Auditor II,
Perkin Elmer Q-Mass
Warranty:
100% non-nonsense warranty. If any customer is unsatisfied
with a DeTech multiplier, the multiplier is replaced immediately
with no questions asked and regardless how long the multiplier
has been on the customer's shelf.
Online-ordering: $1100.00,
Order Quantity:
|
Scientific Instrument Services, Inc. provides replacement detectors from the top manufacturers: Detector Technologies (DeTech), ETP (SGE), and Photonis (formerly Burle). We also offer original equipment detectors. Our detectors are used in a wide array of applications including mass spectrometry, RGAs, process monitoring, photon detection, and ESCA.
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| A41 - DeTech Electron Multipliers for Thermo Systems | 350 |
| A43 - DeTech Electron Multipliers | 350 |
| A44 - DeTech Electron Multipliers | 308, 414A, 473 |
| A45 - DeTech Electron Multipliers | 21010SL, 308, 350, 414A, 464, 473 |
| A48 - Burle* Electron Multipliers | 30071, 30117, 30129, 30131 |
| A49 - Burle* Electron Multipliers | 30071 |
| A51 - ETP Electron Multipliers | 14138, 14532 |
| B23 - Thermo* Mass Spec Accessories | 14138, 30071 |
| B30 - Thermo* Ion Trap Accessories | 350, 350 |
| B45 - Varian SaturnĀ™ Ion Trap Accessories | 30071, 350, 350 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.