C35
Gilibrator
TM
Air Flow Calibration System
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631www.sisweb.com/catalog/08/C35
Primary Standard Airflow Calibration with Interchangeable Flow Cell Assemblies
Kit Descriptions
Complete Kits
All complete kits include control base, bubble generator assem-
bly, flow cell soap and dispenser, battery charger, tubing, carrying
case, and instruction manual.
High Flow Kit
Includes one 2 to 30 LPM Flow Cell Assembly. Contains all items
in "Complete Kit".
Standard Flow Kit
Includes one 20cc/min. to 6 LPM Flow Cell Assembly. Contains
all items in "Complete Kit".
Low Flow Kit
Includes one 1 to 250cc/min. Flow Cell Assembly. Contains all
items in "Complete Kit".
Part No.Description
Standard Gilibrator Kits
Gilibrator-2, High Flow Kit, 120V, 2 to 30 LPM
Gilibrator-2, Std. Flow Kit, 120V, 20 cc to 6 LPM
Gilibrator-2, Low Flow Kit, 120V, 1 to 250cc
Gilibrator-2, Delux Kit - Contains all 3 cells
Diagnostic Kits (include Calibration Panel)
Gilibrator-2, Std. Flow Diagnostic Kit, 120V, 20cc to 6 LPM
Gilibrator-2, Low Flow Diagnostics, 120V, 1 to 250cc
Individual Components
Gilibrator-2 Printer Module
Gilibrator-2 Charger, 120V
Gilibrator-2 Control Base
Gilibrator/Gilibrator-2, Low Flow Cell and Sensor only
Gilibrator/Gilibrator-2, Std. Flow Cell and Sensor only
Gilibrator/Gilibrator-2, High Flow Cell and Sensor only
Gilibrator/Gilibrator-2, Flow Cell Soap
Gilibrator/Gilibrator-2, Soap Dispenser
Gilibrator-2 Battery Pack
All Gilibrator Kits and Diagnostic Kits are also available in 240V version. Call for information.
Gilibrator-2 Ordering Information
The Gilibrator-2 Calibration System is available with your choice
of three (3) interchangeable flow cell assemblies. The twist-on
mounting cells are offered in low flow,
standard flow and high flow versions.
Accuracy:
Greater than 1%
Power:
Internal, rechargeable battery
Battery Life:
Over 300 Charge/Recharge Cycles
Recharge Time:
14 Hours
Input/Voltage:
5.5 - 7.5 Vdc
Input Current:
50 to 60 mA
Operating Temp:
5° to 35°C (41° to 95°F)
Storage Temp:
0° to 50° C (32° to 122°F)
Operating Humidity: 0 to 85% RH
Storage Humidity:
0 to 100% RH, non-condensing
Specifications
Diagnostic Kits
"Diagnostic" kits include all equipment as specified in the
"Complete Kits" plus a Diagnostic Calibrator panel, flow-
tube(s) and pressure gauge, which is built into the carrying
case. Available in Standard and Low only.
Warranty
The Gilibrator system is guaranteed
for one year against defects in parts
and/or workmanship.
The GilibratorTM Air Flow
Calibration System is a primary
calibration system for the accurate
measurement of both positive and
negative gas flows.
Calibration services are also avail-
able. Please call for information.
tip...