These ferrules are constructed from glass filled PTFE, giving the ferrules the sealing properties of PTFE but minimizing the flow problems normally encountered with pure PTFE. All ferrules fit the standard Swagelok, Parker, SGE and other GC fittings. Glass filled PTFE ferrules are ideal for use on mass spectrometer jet separators, glass and metal GC columns and for glass and fused silica capillary columns.
| Glass Filled PTFE Ferrules, ID=1/4 in, UOM=PK | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| GTF410 | (Needs Back Ferrule), pkg of 10 | 0.25 | 0[*L]Standard lead-time for out-of-stock items is approximately two weeks depending on the item. | --- | --- |
| OTF410 | (Does Not Need Back Ferrule), pkg of 10 | 0.25 | 45 | $14.00[*A][*A] 10 or more: 5% off; 50 or more: 10% off. | |
|
Bulk quantity discounts on marked items:
[*A] 10 or more: 5% off; 50 or more: 10% off.
| |||||
|
[*L] Standard lead-time for out-of-stock items is approximately two weeks depending on the item. (#) Call for availability. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
These Vespel ferrules contain 15% graphite.
Because these ferrules are harder, they do not distort and flow as much as other types and are ideal for butt type connections where the flowpath might be interrupted. Greater care must be used when installing these ferrules due to their greater hardness to minimize glass jet breakage. However, these ferrules are usable up to 350 °C. Available in packages of 10.
| Part No. | Description | HP # | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|---|
| 072667 | 1/4 in Graphitized/Vespel Ferrules (Needs Back Ferrule), pkg of 10 | 0100-1500 | PK | 0.25 | 21 | $46.00 | |
| [*L] Standard lead-time for out-of-stock items is approximately two weeks depending on the item. | |||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||||
These are natural or unfilled Vespel ferrules and are a harder material than our graphitized vespel ferrules. Therefore, extreme care must be used when using these ferrules. Vespel ferrules are not normally recommended for jet separators.
Note - Both types of Vespel ferrules form reliable seals, however, with extreme temperature cycling from 300 °C the ferrules may leak due to the natural hysteresis of Vespel. Available in packages of 10.
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| 072680 | Vespel 1/4 in Ferrules (Does Not Need Back Ferrule), pkg of 10 | PK | 0.2 | 0[*L]Standard lead-time for out-of-stock items is approximately two weeks depending on the item. | --- | --- |
|
[*L] Standard lead-time for out-of-stock items is approximately two weeks depending on the item. (#) Call for availability. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Graphite ferrules are 99.95% pure graphite and are extremely easy to use, for obtaining reliable leak free connections. Because graphite does not stick or bind onto the tubing, graphite may be removed and reused. Graphite ferrules are used by many mass spec users on their jet separators due to their ease of removal. However, vacuum seals may not be as efficient as other types of ferrules. Available in packages of 10.
| UOM=PK | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| 072601 | 1/4 in Graphite Ferrules (Needs Back Ferrule) pkg of 10 | 0.25 | 1 | $30.00 | |
| 072621 | 1/4 in Graphite Ferrules (Does Not Need Back Ferrule) pkg of 10 | 0.25 | 0[*L]Standard lead-time for out-of-stock items is approximately two weeks depending on the item. | $30.00 | |
| [*L] Standard lead-time for out-of-stock items is approximately two weeks depending on the item. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| D44 - GC Ferrules & Sealing Rings | GTF410, OTF410 |
| D45 - GC Ferrules & Sealing Rings | 072621 |
| D46 - GC Ferrules & Sealing Rings | 072667 |
| D47 - SGE Ferrules for Agilent Gas Chromatographs | 072601, 072667 |
| D48 - SGE Ferrules for Thermo† & Varian G.C. | 072621, 072667 |
| D49 - SGE Ferrules for Perkin Elmer and Shimadzu GC | 072621, 072667 |
| D50 - SGE GC Ferrules - Instrument Cross Reference | 072601, 072621, 072667 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.