Not an exchange program - your source is cleaned and repaired and returned to you. Scientific Instrument Services now offers a service of mass spectrometer source cleaning. Since we first advertised this service more than one year ago, many of our customers have taken advantage of this new service. This is NOT an exchange program. The same source that we receive from you is cleaned and returned back to you ready to install into your mass spectrometer. 24 Hour Turn Around on Source CleaningFor rush 24 hour turn around, sources should be sent to S.I.S. via Federal Express or other overnight carrier. Once received, they will be cleaned and returned the next day via an overnight carrier such as Federal Express. Please include your purchase order. We can clean and service most models of mass spectrometer sources many of which are listed below. If your source is not one of the ones listed below please contact us. For sources not listed below please include a copy of the manufacturers assembly instructions and schematic of the source assembly when the parts are sent in for repair. Service NotesThe source cleaning article describes in detail the steps and equipment used in the cleaning and repair of all the MS sources that we service at SIS. All parts are thoroughly cleaned, rinsed in solvents and baked out in an oven and ready for installation into the mass spectrometer. Most ceramic insulators will be cleaned or replaced if broken (exception noted below). If old filaments are included with the source, they are repaired and are accurately aligned on the source using an optical video microscope system. If metal parts need to be replaced, this may delay return delivery until we can obtain replacement parts from the manufacturer and additional charged may be incurred. If the source heaters are sent in with the source, additional charges will be incurred if these items are damaged and need additional repairs or replacement. If available, a copy of your source assembly/disassembly schematic from your mass spec manual should be sent in with your source.
All the mass spectrometer sources listed below have been repaired by S.I.S. in
the last few months. If your mass spectrometer source is not listed below, it can still
be repaired by S.I.S. Send your source with old filament(s) attached, along
with your purchase order to: |
Agilent (Hewlett Packard) 5988 Source Cleaning
Cleaning of the Agilent (Hewlett Packard) 5988 Source begins with the complete disassembly of the source and lens stack assembly. Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven. All ceramic insulators are sandblasted followed by solvent washing and bake out. Vespel insulators are washed in solvent and baked out. If the Vespel insulators are broken, they will need to be replaced at additional cost. The filament and target assemblies are cleaned. A new filament is installed on the filament assembly ceramic. The ceramic insulators on the target and filament assembly are not replaced if missing or damaged beyond repair. Replacement of these parts will incur additional costs as outlined below. The plunger assembly is disassembled, the repeller and repeller insulator are polished and cleaned and the plunger body repeller surface is polished and solvent cleaned. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filament is accurately aligned over the ion entrance hole and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. Parts Cleaned: entire source block, lenses, insulators, target, filament and plunger assembly. Parts Replaced if missing or broken: Lens stack insulators and new filament. Not included in standard source cleaning price: replacement of missing screws and other metal source parts as well as broken or missing filament and target ceramics, repeller insulator, and plunger guide. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage in shipment. |
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP77 | Source Cleaning of HP 5988/5989 | EA | 5 | 0(#) | $450.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Agilent (Hewlett Packard) 5989 Source Cleaning
Cleaning of the Agilent (Hewlett Packard) 5989 Source begins with the complete disassembly of the source. Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven. All ceramic insulators are sandblasted followed by solvent washing and bake out. Vespel insulators are washed in solvent and baked out. If the Vespel insulators are broken, they will need to be replaced at additional cost. The filament and target assemblies are cleaned. A new filament is installed on the filament assembly ceramic. The ceramic insulators on the target and filament assembly are not replaced if missing or damaged beyond repair. Replacement of these parts will incur additional costs as outlined below. The plunger assembly is disassembled, the repeller and repeller insulator are polished and cleaned and the plunger body repeller surface is polished and solvent cleaned. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filament is accurately aligned over the ion entrance hole and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. Parts Cleaned: entire source block, lenses, insulators, target, filament and plunger assembly. Parts replaced if missing or broken: Plate insulators and new filament. Not included in standard source cleaning price: replacement of missing screws and other metal source parts as well as broken or missing filament and target ceramics, repeller insulator, and plunger guide. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage in shipment.
|
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP77 | Source Cleaning of HP 5988/5989 | EA | 5 | 0(#) | $450.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Agilent (Hewlett Packard) 5970 Source Cleaning
Cleaning of the Agilent (Hewlett Packard) 5970 Source begins with the complete disassembly of the source and lens stack assembly. Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven. All ceramic insulators are sandblasted followed by solvent washing and bake out. Vespel insulators are washed in solvent and baked out. If the Vespel insulators are broken, they will need to be replaced at additional cost. The filament block assembly is disassembled, sandblasted, solvent washed and then baked out. Two new filaments are installed on the filament block ceramic. The filament block ceramic is not replaced if missing or damaged beyond repair. Replacement of this part will incur additional costs. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filaments are accurately aligned over the ion entrance holes and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. Parts Cleaned: entire source block, lens stack assembly, insulators, filament and repeller assembly. Parts Replaced if missing or broken: Two new filaments and lens ceramic spacer. Not included in standard source cleaning price: replacement of missing screws and other metal source parts as well as broken or missing filament and target ceramics, repeller insulator, and plunger guide. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage in shipment.
|
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP76 | Source Cleaning of HP 5970 | EA | 5 | 0(#) | $435.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Agilent (Hewlett Packard) 5971, 5972, and GCD Source Cleaning
Cleaning of the Agilent (Hewlett Packard) 5971/5972/GCD Source begins with the complete disassembly of the source. Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven. Vespel insulators are washed in solvent and baked out. If the Vespel insulators are broken, they will need to be replaced at additional cost as outlined below. The two filament assemblies are repaired. New replacement filaments are not available through S.I.S. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filaments are accurately aligned over the ion entrance holes and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. Parts cleaned: entire source block, lenses, insulators, filament and repeller assembly. Parts Repaired: two filaments Not included in standard source cleaning price: replacement of missing screws and other metal source parts as well as broken or missing filament and target ceramics, repeller insulator, and plunger guide. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage in shipment.
|
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP100 | Source Cleaning of HP 5971/5972/GCD | EA | 5 | 0(#) | $330.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Finnigan MAT 4500/TSQ Source Cleaning
Cleaning of the Finnigan MAT 4500/TSQ Source begins with the complete disassembly of the source. Cleaning and polishing of all metal parts is followed by thorough washing and bake out in an oven. All ceramic insulators are sandblasted followed by solvent washing and bake out. Anodized aluminum insulators are washed in solvent and baked out. If these insulators are scratched or broken, they will need to be replaced at additional cost. The filament, collector and heater are cleaned and repaired if broken. These parts are not replaced if missing or damaged beyond repair. Replacement of these parts will incur additional costs. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filament is accurately aligned over the ion entrance hole and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. If the source is shipped with the source mounting flange assembly, the source is mounted onto this flange and all leads are connected and checked for continuity. If leads need to be replace, an additional charge will be incurred. Parts Cleaned: entire source block, lens, insulators, collector, heater, filament and ion volume assembly. Parts Repaired: Filament, collector and heater. Parts replaced if missing or broken: Lens retainer springs. Not included in standard source cleaning price: replacement of castle spacer lens and lens ring retainer ceramic or anodized aluminum insulators. Also not included are the replacement of the filament, collector and heater assembly or any other missing mechanical parts. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The entire flange mounting assembly is not normally shipped for repair due to the heavy weight and delicate nature of this component. All source parts should be thoroughly packaged with packing material to avoid damage during shipment. If the Flange assembly is sent in for repair, it should be mounted on the original plastic mounting bracket supplied with the mass spec. This assembly should then be thoroughly packaged with packaging material and then double boxed to avoid damage in shipment. This flange assembly is very delicate and easily damaged in shipment.
|
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP79 | Source Cleaning of Finn MAT 4500/TSQ | EA | 3 | 0(#) | $435.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
VG TRIO Source Cleaning
Cleaning of the VG TRIO Source begins with the complete disassembly of the source and lens stack assembly. Cleaning and polishing of all metal parts are followed by thorough washing and bake out in an oven. All ceramic insulators are sandblasted followed by solvent washing and bake out. The filament assemblies are cleaned and repaired. The ceramic insulators on the target and filament assembly are not replaced if missing or damaged beyond repair. Replacement of these parts will incur additional costs as outlined below. After all parts have been repaired, cleaned and baked out, the source is reassembled. The filament is accurately aligned over the ion entrance hole and clamped in place. The source is checked for resistance leaks as well as visual alignment of all parts. Parts Cleaned: entire source block, lenses, insulators, target and filament. Parts Repaired: Filament. Not included in standard source cleaning price: replacement of missing screws and other metal source parts as well as missing filament, heater or temperature sensor. Shipping in for Repair: Normally the source block and associated parts are shipped in for repair. The source should be thoroughly wrapped in packaging material and double boxed to avoid damage in shipment. |
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP74 | Source Cleaning of VG TRIO | EA | 5 | 0(#) | $560.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Scientific Instrument Services can clean and service most models of mass spectrometer sources many of which are listed above. If your source is not one of the ones listed above please contact us . For new sources not listed above please include a copy of the manufacturers assembly instructions and schematic of the source assembly when the parts are sent in for repair. These drawings will aid us in the disassembly and reassembly of your source.
| SIS Catalog Cross Reference | |
|---|---|
| Page # | Part Numbers |
| A5 - Agilent Mass Spectrometer Source Cleaning | REP100, REP76, REP77 |
| A6 - Thermo Mass Spectrometer Source Cleaning | REP79 |
| A7 - VG Mass Spectrometer Source Cleaning | REP74 |
| A8 - Other Mass Spectrometer Source Cleaning | REP77 |
| B18 - Thermo* MS Source Cleaning by S.I.S.™ | REP79 |
| B6 - Agilent MS Source Cleaning by S.I.S.™ | REP100, REP76, REP77 |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.