- Catalog Page C1Short Path™ Thermal Desorption TD-5 [C2] Short Path™ Thermal Desorption TD-5 [C3] Short Path™ Thermal Desorption System TD-5 [C4] Short Path™ Thermal Desorption TD-5 [C5] AutoDesorb™ [C6] AutoDesorb™ [C7] AutoDesorb™ [C8] AutoDesorb™ [C9] Short Path™ Thermal Desorption Tubes [C10] Desorption System Fittings [C11] TD1/TD2/TD3/TD4/TD5/ Needles & Seals [C12] AutoDesorb™ Needles, Seals & Connecting Tubes [C13] Adsorbent Resin for Trapping Volatiles [C14] Adsorbent Resin for Trapping Volatiles [C15] Thermal Desorption Conditioning System [C16] Thermal Desorption Conditioning System [C17] Heated Thermal Desorption Sampling Chambers [C18] Extraction Cell for Papers, Polymers & Food Containers [C19] Thermal Desorption Sample Collection System [C20] Thermal Desorption Sample Collection System [C21] Cryo-Trap™ for TD-5 [C22] Cryo-Trap™ for the AutoDesorb™ System [C23] Purge & Trap System [C24] Temperature Controller & Heater Sleeves [C25] Thermal Desorption Accessories [C26] Thermal Desorption Low Flow Air Sampling Pump [C27] Gilibrator™ Air Flow Calibration System [C28] Gilibrator™ Air Flow Calibration System [C29] ALTEF Gas Sampling Bags [C30]
- ▶
- Catalog Page C4 (This Page)
Short Path™ Thermal Desorption TD-5
C4
Phone: 908-788-5550
www.sisweb.com
Software
T
he SIS Thermal Desorption Software included
provides visualization and control of all thermal desorp-
tion operations through a user-friendly graphical user
interface. The user may configure system and thermal desorption
methods settings (e.g. times and temperatures) as well as monitor
the system status (e.g. temperatures and pressures) during a run.
The Thermal Desorption Software can be used fully indepen-
dent of the GC data system, or it can be fully integrated with cer-
tain GC data systems (e.g. Agilent ChemStation™
or Thermo
Xcalibur™
). When the software is integrated with ChemStation,
MassHunter, and Xcalibur™
thermal desorption parameters get
stored directly into the current ChemStation method so that GC
and thermal desorption method settings are linked. The run is initi-
ated from ChemStation, and methods may be changed between
samples to provide different desorption parameters for different
samples. For example, a separate high temperature bakeout or
blank method can be setup and run between samples to assure
the system is clean for the next sample. The software operates
Microsoft Windows operating systems.
View/edit TD method parameters
View sample log
Monitor run status
Load/save methods, run
samples, configure system
and browse help
SIS Thermal Desorption Software
Features:
•
Configure system parameters and limits
•
Configure thermal desorption methods
including desorption and cryo-trap times
and temperatures.
•
Monitor system status including actual
times, temperatures, pressures and status
during a run.
•
Log sample status and errors.
•
View online help system.
•
RS-232 (optional USB bridge) communication
with TD-5 instrument.
•
Optional Agilent ChemStation, MassHunter or
Thermo Xcalibur integration for method
load/save and sample run.
•
The Cryo-Trap may be operated separately for
syringe injections.