Print Catalog B. Supplies for Specific Mass Spectrometers Mass Spectrometer Source Cleaning [A2] Agilent Mass Spectrometer Source Cleaning [A3] Thermo Mass Spectrometer Source Cleaning [A4] VG Mass Spectrometer Source Cleaning [A5] Other Mass Spectrometer Source Cleaning [A6] Filament & Heater Repair [A7] Filament & Heater Repair [A8] Filament & Heater Repair [A9] Filament & Heater Repair [A10] Filament & Heater Repair [A11] Filament & Heater Repair [A12] Filament & Heater Repair [A13] Filament & Heater Repair [A14] Filament & Heater Repair [A15] Filament & Heater Repair [A16] Filament & Heater Repair [A17] Filament & Heater Repair [A18] X-Ray Generator Filament & Heater Repair [A19] New Mass Spec Filaments by SIS™ [A20] New Mass Spec Filaments [A21] New Mass Spec Filaments [A22] New Mass Spec Filaments [A23] New Mass Spec Filaments [A24] Mass Spec Source Heaters [A25] MS Cartridge Heaters [A26] MS Cartridge Heaters [A27] Platinum Resistance Thermometers [A28] Platinum Resistance Thermometers [A29] Heating Tapes [A30] Filament & Heater Material [A31] Filament & Heater Material [A32] Filament & Heater Material [A33] Filament & Heater Material/Heater Coils [A34] Electrical Connectors [A35] DeTech Electron Multipliers [A36] DeTech Electron Multipliers for Thermo Systems [A37] DeTech Electron Multipliers for Agilent Systems [A38] DeTech Electron Multipliers [A39] ? ? ? ETP Electron Multipliers [A43] Electron Multiplier Cross Reference [A44] Electron Multiplier Cross Reference [A45] Electron Multiplier Cross Reference [A46] Electron Multiplier Cross Reference [A47] Direct Insertion Probe for Agilent 5973, 5975 & 5977 [A48] Direct Insertion Probe for Agilent 5973, 5975 & 5977 [A49] ? Direct Probe Sample Vials [A51] Sample Vials & Sample Vial Blocks [A52] Quartz Sample Vials & Pyrolysis [A53] Calibration Compound [A54] Ceramic Cement, Fish Spines & Sapphire Balls [A55] MALDI-TOF Supplies [A56] MALDI-TOF Supplies [A57] Ceramic Tubes [A58] Ceramic Insulators [A59] Ceramic Insulators [A60] Ceramic Insulators [A61] Ceramic Insulators [A62] Micro-Mesh® Cushioned Abrasive Sheets [A63] Micro-Mesh® Cushioned Abrasive Sheets [A64] Micro-Mesh® Cushioned Abrasive Sheets [A65] Micro-Mesh® Kits & Other Products [A66] Instrument Cleaning Supplies [A67] Discontinued [E48] Discontinued [E48] SIMION™ Version 8.1 [A70] SIMION™ Version 8.1 [A71] NIST Mass Spectral Library & Software [A72] NIST Mass Spectral Library & Software [A73] Wiley Mass Spectral Libraries [A74] Wiley Mass Spectral Libraries [A75] Wiley Mass Spectral Libraries [A76]
- ▶
- Catalog Page A2 (This Page)
A2
Phone: 908-788-5550
www.sisweb.com
Mass Spectrometer Source Cleaning
A small buffing wheel is used
to polish metal filament and
source parts to a high luster.
Parts are thoroughly cleaned
in solvents and rinsed in a
state-of-the-art
ultrasonic aqueous
cleaning system.
Service Notes
Source cleaning begins with the complete disassembly of the
source. The metal parts are cleaned and polished, then washed in
solvents and baked out in an oven. All ceramic insulators are
sandblasted followed by solvent washing and bake out. If broken,
most of these ceramics can be replaced at no extra cost, with the ex-
ception of those with a cost of $50.00 or more. Vespel insulators are
washed in solvent and baked out. If old filaments are included on the
source they are repaired at no extra charge.
Additional charges may be incurred if metal parts, source heaters,
thermocouples or filaments damaged beyond repair need to be re-
placed. If Vespel insulators are broken or missing, they will need to
be replaced at an additional cost.
After all parts have been repaired, cleaned and baked out, the
source is reassembled. The filament is reinstalled and accurately
aligned over the source hole. The source is checked for resistance
leaks as well as visual alignment of all parts.
Not included in repairs are the replacement of the filaments,
collectors, heaters, screws or other missing parts.
Normal turn around is 72 hours unless components need to be
replaced that we need to custom order from the manufacturer.
24 Hour Turnaround on Source Cleaning
For rush 24 hour turn around, sources should be sent to SIS via
Federal Express or other overnight carrier. Once received, they will
be cleaned and shipped the next day via an overnight carrier such
as Federal Express. Please include your purchase order. If your
source is not one of the ones listed, please include a copy of the
manufacturers assembly instructions and schematic of the source
assembly.
Shipping in for Repair
Normally the source block and associated parts should be
shipped in for repair. The source should be thoroughly wrapped in
packaging material and double boxed to avoid damage in shipment.
If available, a copy of your source assembly/disassembly schematic
from your mass spec manual should be sent in with your source.
•
Not an exchange program - your source is cleaned,
repaired and returned to you.
•
Filaments repaired and accurately aligned on source.
•
24 hour turnaround is available, additional charges may apply.
Expert Cleaning and Repair of Mass Spectrometer Sources
Assembly of Source is Done in a Dust
Free Clean Environment
Filaments are sandblasted with aluminum oxide and glass
beads to remove impurities.
Filament Aligned on MS Source
In addition to the sources listed in the next few pages, SIS™ can clean and repair sources from any other mass spectrometers. Call
SIS™ with your requirements.
We will clean and repair your mass spectrometer source.
Additional Mass Spectrometer Sources Repaired
S
cientific Instrument Services™ now offers mass spectrometer
source cleaning. Since we first advertised this service in our
January 1994 newsletter, many of our customers have taken
advantage of this offer. This is NOT an exchange program. The same
source that we receive from you is cleaned, repaired and returned back
to you ready to install into your mass spectrometer.