Analytical Column System
E8
Scientific Instrument Services, Inc.
TM
Phone: 908-788-5550
www.sisweb.com/catalog/08/E8
A
ll the information you need to order Velocity column cartridges is included in the table below. Follow these instructions to build
the correct part number for the columns you require.
1)
The Part Number column on the left side of the table lists part numbers that correspond to unique column length and ID
dimensions, in millimeters. Start by choosing the correct 7 digit number for the dimension you need (e.g. 12-02401-** for a 2.1 x
15mm column.)
2)
Each Velocity part number requires a two letter PACKING CODE to designate the packing material required -- this CODE will
replace "**" in the part number found above. Packing materials are listed at the top of the table, and are aligned vertically with
the corresponding Packing Codes, shown at the bottom of the table.
3)
Prices are listed on the right side of the table, in "matrix" format. To find the correct price for the column of your choice, find the
pricing cell that aligns horizontally with packing type and vertically wIth column dimension -- that's your list price.
Custom Phases
We also offer Velocity custom-packed in any of the following custom phases, usually without any kind of custom packing charge. We
can also pack Velocity with any bulk-material you wish to supply. A small lead-time usually applies, and custom-packed columns must be
ordered in quanitities of three or more at a time. If you don't see the material you require listed here, please contact SIS to find out if it is
available.
Intersil: 100Å Pore size, 5µm Particle Size
Silica, ODS-2, C
8
, C
4
, Phenyl
Kromasil: 100Å Pore size, 3µm and 5µm Particle Size
Silica, C
18
, C
8
, C
4
, C
1
, NH
2
Monitor: 100Å Pore size, 3µm and 5µm Particle Size
C
18
, C
8
Nucleosil: 100Å & 300Å Pore size, 3µm and 5µm Particle Size
Silica, C
18
, C
8
, CN, NH
2
Reliasil: 100Å & 300Å Pore size, 3µm and 5µm Particle Size
Silica, C
18
, C
8
, C
4
, NH
2
, CN, SCX, SAX
Spherisorb: 80Å Pore size, 3µm and 5µm Particle Size
Silica, ODS2 (C18), C8, C6, C4, C1, NH2,
SAX, SCX
Quantity Discount Information
Order in quantity and save! We are offering quantity discounts when you purchase three columns on the same order, for
a 5% discount.
ID
Length
C18
C18
C18
Part No.
(mm)
(mm)
3µm
5µm
3µm
5µm
3µm
5µm
12-02401-
**
2.1
15
12-02402-
**
2.1
30
12-02403-
**
2.1
50
12-02404-
**
2.1
100
12-02411-
**
3.0
15
12-02412-
**
3.0
30
12-02413-
**
3.0
50
12-02414-
**
3.0
100
12-02421-
**
4.6
15
12-02422-
**
4.6
30
12-02423-
**
4.6
50
12-02424-
**
4.6
100
Two Digit Letter Code KA
KB
RA
RB
MA
MB
Kromasil® 100Å
Reliasil® 100Å
Monitor® 100Å
tip...
| Page | Parts |
|---|
| Optimize Technologies Velocity Analytical HPLC Column System | 1202401KA, 1202401KB, 1202411KA, 1202401MA, 1202411KB, 1202401MB, 1202403KA, 1202403KB, 1202421KA, 1202411MA, 1202421KB, 1202411MB, 1202413KA, 1202403MA, 1202413KB, 1202403MB, 1202421MA, 1202421MB, 1202423KA, 1202413MA, 1202423KB, 1202413MB, 1202402RA, 1202423MA, 1202402RB, 1202423MB, 1202412RA, 1202412RB, 1202422RA, 1202422RB, 1202402KA, 1202402KB, 1202402MA, 1202412KA, 1202402MB, 1202412KB, 1202422KA, 1202412MA, 1202422KB, 1202412MB, 1202401RA, 1202422MA, 1202401RB, 1202422MB, 1202411RA, 1202411RB, 1202403RA, 1202403RB, 1202421RA, 1202421RB, 1202413RA, 1202413RB, 1202423RA, 1202423RB |