D15
VICI ValcoPLOT
®
Capillary Columns
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631
www.sisweb.com/catalog/08/D15
VP-Alumina
Aluminum oxide
With ValcoPLOT Al2O3 PLOT columns
there's no need for cryogenic equipment to
analyze C1 - C5 hydrocarbons in a main
stream of C1 - C5 hydrocarbons. ValcoPLOT
Al2O3 columns are deactivated with small salt
crystals stable to 200°C. KCl deactivation
produces a relatively apolar column while
Na
2
SO
4
produces columns exhibiting increased
retention of unsaturated hydrocarbons.
Similar Phases
GS-Alumina, HP-PLOT Al2O3, CP-Al2O3/KCl, CP-Al2O3/Na2SO4, Rt-alumina-
PLOT, Al2O3/KCl, Al2O3/Na2SO4
Film
Temperature
I.D.
Length
Thickness
Limits
Part
(mm)
(meter)
(µm)
(°C)
Number
VP-Alumina/KCl
0.32
15
5
-60° to 200°C
30
5
-60° to 200°C
0.53
15
10
-60° to 200°C
30
10
-60° to 200°C
50
10
-60° to 200°C
VP-Alumina/Na2SO4
0.32
15
5
-60° to 200°C
0.53
15
10
-60° to 200°C
30
10
-60° to 200°C
50
10
-60° to 200°C
Applications
C1-C3 hydrocarbons, Cryogenic analysis of light
gases, Solvents
Film
Temperature
I.D.
Length
Thickness
Limits
Part
(mm)
(meter)
(µm)
(°C)
Number
Fused silica
0.32
15
10
-60° to 165°C
30
10
-60° to 165°C
0.53
15
20
-60° to 165°C
Stainless Steel
0.53
30
20
-60° to 165°C
VP-Molesieve
Molesieve 5Å
ValcoPLOT Molesieve 5Å PLOT columns
offer greatly enhanced analytical efficiency at
economical prices. No need for cryogenic
equipment to analyze Ar/O2 with our thick film
columns. ValcoPLOT Molesieve 5Å PLOT thin
film columns offer fast elution of carbon
monoxide with near perfect peak symmetry.
Our proprietary bonding technology insures
that the particles stay put even when used with
valves.
Film
Temperature
I.D.
Length
Thickness
Limits
Part
(mm)
(meter)
(µm)
(°C)
Number
Fused silica
0.32
15
10
350/350°C
30
10
350/350°C
0.53
15
15
350/350°C
15
20
350/350°C
15
50
350/350°C
30
15
350/350°C
30
20
350/350°C
30
50
350/350°C
50
15
350/350°C
Stainless steel
0.53
15
15
350/350°C
30
15
350/350°C
HayeSep
®
A
High Purity Divinylbenzene/
ethyleneglycoldimethacrylate
This phase is available exclusively from VICI.
Applications
C1-C3 hydrocarbons, Solvents
Film
Temperature
I.D.
Length
Thickness
Limits
Part
(mm)
(meter)
(µm)
(°C)
Number
Fused silica
0.32
15
10
-60° to 190°C
30
10
-60° to 190°C
0.53
15
20
-60° to 190°C
30
20
-60° to 190°C
Stainless Steel
0.53
30
20
-60° to 190°C
HayeSep
®
B
Divinylbenzene/Polyethyleneimine
This phase is available exclusively from VICI.
Applications
C1-C5 hydrocarbons,
Similar Phases
GS-Molesieve 5A, HP-PLOT Molesieve, CP-Molesieve 5A, Rt-Msieve-5A, MXT-
Msieve-5A, PLT-5A
Applications
Air
tip...