AutoProbe
A
technique is of little use if “cross contamination” or
“memory effects” occur during sample analysis. This
problem does not occur in the AutoProbe because the
DEP wire is “baked out” at high temperatures between
samples. The chromatograms below show the analysis of a 250 ng
Cholestane sample dissolved in methanol. This analysis was
repeated 5 times. The DEP coil was baked out at 900 mA for 15
seconds after each sample and then a blank clean methanol sam-
ple was analyzed. The blank injection produced a flat baseline with
no carryover from the previous samples.
The charts below show the MS data at 0.18 minutes for the 250
ng of Cholestane and the blank methanol sample. Note that the
scale on the blank methanol spectrum is 1000 times the scale of the
250 nanogram of Cholestane. No peaks were found in the blank
sample that could be attributed to the Cholestane. In this study, as
well as many others, it was confirmed that “memory effects” or
“cross contamination” problems do not occur with the AutoProbe
technique. It is recommended that the high temperature “bake out”
be used in all analysis. A blank sample between analysis is option-
al.
Sensitivity
Direct probe techniques are less sensitive than GC techniques
because the probe peaks in the total ion chromatograph are com-
paratively much wider and therefore less intense. However, by uti-
lizing the rapid temperature ramp capabilities of the AutoProbe,
sample sizes less than one nanogram have been detected and
identified.
Additional information is available on the web at:
www.sisweb.com/autoprobe
Background Check After Running Strong Samples
Typical Calibration Curve for an Analyte Using the AutoProbe
Background MS After Running 5 Consecutive Strong Samples
Voltages
AutoProbe Console Voltage:
110 VAC or 220 VAC
Edwards Vacuum Pump:
110 VAC or 220 VAC
Compressed Air: minimum 60 psi
Mass Spectrometer System Requirements
Thermo TRACE DSQ
or Polaris Q
MS
System with Xcalibur™Software
(Trace MS supported in our AP1000 AutoProbe)
Dimensions
Console without CTC PAL Autosampler:
17” wide x 42” Deep x 16” High
Console with CTC PAL Autosampler:
23” wide x 42” Deep x 37” High
Weight
Console Weight:
100 pounds
TRACE DSQ™, TRACE MS, Focus DSQ, DSQ II, Polaris Q™,
Thermo™, Xcalibur™, and Open Access™ are Trademarks of Thermo
Electron Corporation. - for mor information visit
www.thermofinnigan.com
AutoProbe System Specifications & Requirements
Part No.
Description
AP2000 Part #AP2000--Click to order
Current Price: $69950.00
Unit of Measure: EA
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.
AutoProbe System
AP20001 Part #AP20001--Click to order
Current Price: $325.00
Unit of Measure: EA
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.
AutoProbe DCI Filament
AP20002 Part #AP20002--Click to order
Current Price: $275.00
Unit of Measure: EA
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.
Calibration Tip
AP20004 Part #AP20004--Click to order
Current Price: $68.50
Unit of Measure: EA
Not in stock. Standard lead time for out-of-stock items is approximately two weeks.
AutoProbe Seal Set
Scientific Instrument Services, Inc.
FAX: 908-806-6631
www.sisweb.com/catalog/08/A59
Related information may be found on the following pages of our web site:
PageParts
Centering Ring AssemblyQF50200ARV
Page Number: [ previous page next page ]
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2012 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Navigation

SIS Newsletter
Covers SIS products, services, promotions, news, and other mass spectrometer related information.