SECTION I - PRODUCT IDENTIFICATION
MANUFACTURERS NAME:
Econoline Abrasive Products, Inc. Emergency Phone: 616-846-4150 335 N. Griffin Street Phone: 616-846-4150 Grand Haven, MI 49417 Date Prepared: August 19, 1991 IDENTITY: BT-R
SYNONYMS: Aluminum Oxide-Brown
CHEMICAL FAMILY: Oxides
CAS#:
SECTION II - HAZARDOUS INGREDIENTS/INDENTITY INFORMATION
COMMON CHEMICAL NAME: Fused Aluminum Oxide-Brown
HAZARDOUS COMPONENTS OSHA ACGIH
Specific Chemical Identity: Common Name PEL TLV
Nuisance Dust 10mg/m3
Other Limits: Recommended amount of dust depends on particle size.
NON HAZARDOUS COMPONENTS
Common Chemical Name
Fused Aluminum Oxide- Brown
Chemical Formula Al-2-0-3
SECTION - III PHYSICAL/CHEMICAL CHARACTERISTICS
Boiling Point: 600 F Specific Gravity (H20=1): 4,0 Vapor Pressure: N/A Softening Point: N/A Vapor Density: N/A Evap. Rate (Butyl Acetate=1): N/A Solubility in Water: N/A Appearance & Odor: Crystalline Particles, No Odor
SECTION IV - FIRE AND EXPLOSION HAZARD DATA
Flash Point: N/A
Extinguishing Media: Nonflammable
Special Fire Fighting Procedures: NONE
Unusual Fire and Explosion Hazards: NONE
SECTION V - REACTIVITY DATA
Stability: Yes Conditions to Avoid: Material is stable
Incompatibility (Materials to Avoid): None
Hazardous Decomposition or Byproducts: N/A
Hazardous Polymerization: Will not Occur Conditions to Avoid: None Known
SECTION V I- HEALTH HAZARD DATA
Routes of Entry:
INHALATION
Health Hazard (Acute and Chronic): Dust in excess of recommended exposure limits may result in irritation to the respiratory tract.
CARCINOGENICITY: NTP IARC Monographs OSHA Regulation
not listed not listed not listed
SIGNS AND SYMPTOMS OF EXPOSURE: Eye and respiratory irritation may result if recommended exposure limits are exceeded
MEDICAL CONDITIONS GENERALLY AGGRAVATED BY EXPOSURE: Chronic lung conditions may be aggravated by exposure to high concentrations of dust.
EMERGENCY AND FIRST AID PROCEDURES: Remove to fresh air.
SECTION VII - PRECAUTIONS FOR SAFE HANDLING AND USE
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Sweep up discard. Avoid excessive dusting.
WASTE DISPOSAL METHOD: May be disposed of in approved landfill in accordance with federal, state and local regulations.
PRECAUTIONS TO BE TAKEN IN STORAGE AND HANDLING: Use adequate ventilation so as to avoid exceeding TLV.
OTHER PRECAUTIONS: None
SECTION VIII - CONTROL MEASURES
RESPIRATORY PROTECTION: NIOSH approved dust mask, if recommended exposure limits are exceeded.
VENTILATION: Local exhaust
EYE PROTECTION: NIOSH approved safety glasses
PROTECTIVE GLOVES: None
OTHER PROTECTIVE CLOTHING OR EQUIPMENT: None
ABBREVIATION CODES: N/A - Not Applicable g/cc - grams per cubic centimeter
Mg/m3 - milligrams per cubic meter
NOTE: This information is furnished without warranty, representation, inducement or license of any kind, except that it is accurate to be best of Econoline Abrasive Products, knowledge, or obtained from sources believed by Econoline to be accurate, and Econoline does not assume any legal responsibility for or reliance upon same. customers are encouraged to conduct their own tests.
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.