5971 Bayard Alpert Vacuum Measurement System
T
he vacuum measurement system to monitor the source pressure is optional for
the 5971. A complete system is available from S.I.S. to measure the source pres-
sure. The system consists of a model 330 ion gauge controller, an ion gauge
adaptor, a G75K ion gauge tube and a cable. This Bayard Alpert style vacuum gauge tube
and controller is an exact replacement for the optional system available from Agilent The
adaptor is inserted between the NW25 flange at the bottom of the analyzer and the cali-
bration gas vial.
Part No.
Description
330 Ion Gauge Controller, Bayard Alpert
10' Cable
3/4" Bayard Alpert Ion Gauge Tube
Ion Gauge Adaptor
A complete system consists of one each of the above items.
Convectron Gauge Tube
The
Granville
Philips
Convectron Gauge tube used on
the 5971 & 5972 mass spectrome-
ters is available from S.I.S. This is
a direct replacement for the Agilent
original and screws into the fitting
shown above.
New Agilent 5971 Transfer Line Tip
The transfer line tip for the Agilent 5971 MSD has been redesigned to permit the effluent from the end
of the capillary column to purge directly into the MSD source, unlike the original gold plated transfer line
tip in which the effluent purged inside this fitting and was diverted through side vents. This new design elim-
inates any inlet metal contact with the sample. The capillary column protrudes slightly through the end of
the tip directly into the source. This new design should result in higher sensitivity for compounds which are
sensitive to any metal contact.
Part No.
Description
3/4" 5971 Hose Fitting
1" 5971 Hose Fitting
Part No.
Description
Agilent Part #
Convectron Tube
0960-0540
Part No.
Description
Agilent Part #
Agilent 5971 Transfer Line Tip
05971-20305
Agilent 5971 Feedthrough
Repair
The feedthroughs on the 5971 analyzer
top plate can be replaced by S.I.S. These
feedthroughs are very fragile and susceptible
to damage. Repair includes drilling out the old
feedthrough, TIG welding a
new feedthrough in place,
and helium Leak Testing of
repaired feedthrough. This
repair requires returning the
analyzer top plate. We will
repair within 24 hours and
return it via Federal Express.
Part No.
Description
Replacement of One Feedthrough
Replacement of Two Feedthroughs
Part No.
Description
5971 Interface Repair
Temperature Sensor, 5971 Interface
Heater, 5971 Interface
Hose Adaptor Fittings
The hose fitting used in the back
of the 5971 when the Convectron
Gauge Tube is mounted is available
from S.I.S. The standard fitting is for
3/4" hose. We also offer a fitting for
use with 1" diameter hose.
Agilent 5971 Interface Repair
The GC/MS Interface on the Agilent
Technologies
5971
MSD
can
be
damaged if care is not used. The 1/16"
Swagelok fitting can be broken or stripped if
overtightened. S.I.S. can replace this fitting if it
becomes damaged.
tip...