Agilent GC Injection Port Repair
The injection port used on the Agilent Technologies GC and GC/MS systems can be repaired. The SS line can become clogged, bro-
ken or the joint can leak. S.I.S. can replace the line with a new 1/16" SS line. If the weld is leaking, but the SS line is fine, then we can
reweld the silver solder joint. All repairs include cleaning and leak testing of the joint.
Agilent 5890/6890 GC Injection Port Repair
B
oth the old style and the new style injection ports from the Agilent Technologies
5970 GC/MS system can be repaired by S.I.S. This injection port is Agilent
#19251-60520. The stainless steel lines often develop leaks where they are
welded to the injection port or the lines can become clogged or kinked. S.I.S. will repair or
replace the lines as required.
Part No.
Description
REP8W
Reweld S.S. lines
REP81
Replace one S.S. line
REP82
Replace two S.S. lines
Part No.
Description
REP14
Agilent Probe
Agilent DIP Probe Repair
The DIP Probes for the Agilent 5980 mass spectrometers can be repaired by S.I.S.
This repair includes replacing the heater and thermocouple and checking for leaks. The
electrical BNC connector can also be replaced, if necessary.
Part No.
Description
Reweld S.S. line
Replace S.S. line
Agilent 5971 Feedthrough Repair
The feedthroughs on the 5971 analyzer top plate can be replaced by S.I.S. These feedthroughs are
very fragile and susceptible to damage. Repair includes drilling out the old feedthrough, TIG welding a
new feedthrough in place, and helium leak testing of repaired feedthrough. This repair requires returning
the analyzer top plate.
Part No.
Description
Replacement of One Feedthrough
Replacement of Two Feedthroughs
tip...
Page Number: [ previous page next page ]
Related information may be found on the following pages of our web site:
PageParts
Hewlett Packard Repair of Feedthru on FlangesREP211, REP212
Hewlett Packard 5971 Feedthru RepairREP211, REP212
Hewlett Packard GC Injection Port RepairREP85, REP86
Hewlett Packard DIP Probe RepairREP14
Finnigan Flange and Feedthru RepairREP211, REP212
Hewlett Packard MSD Injection Port RepairREP81, REP82, REP8W
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call/e-mail/FAX us, or type your comments below.
Name/organization:
Email: Phone/fax:
Regular business hours are 8:00 AM to 5:30 PM EST, M-F.
E-mail replies are normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL: contact us WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551.
© 1996-2008 Scientific Instrument Services, Inc. [Trademarks]