B11
Agilent 5973/5975 Accessories by S.I.S.
TM
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631
www.sisweb.com/catalog/08/B11
Agilent 5973 CI and EI New Filaments and Filament
Repair
New Agilent original filaments are available from S.I.S. The Agilent Technologies
5973 CI and EI filament assembly can also be repaired by S.I.S. This includes com-
plete cleaning and replacement of filament wire.
Repair of Collector & Entrance Lens Agilent 5973
Agilent 5973 Diffusion
Pump
T
he Model EO50/60 is a compact,
fast warm-up air-cooled diffusion
pump supplied complete with
high integrity inlet Co-seal, flange clamping
ring and optional baffle. The jet assembly is
removable for easy cleaning.
In many applications the rapid warm-up
capability will enable the EO50/60 to be used without an isola-
tion valve. However, the pump is not intended for use on valve-
less systems where rapid cycling from atmospheric pressure
through the hot pump is required.
Models are available with and without cooling fans. Models
without fans are available as replacement diffusion pumps for
Agilent MSD instruments.
If the connector pins on the
entrance lens or ion focus lens
become damaged or broken, they
can be repaired in our shops.
Mini Ion Gauge Tube and Controller for the Agilent 5972/5973/5975
Ion Gauge
Tube
Part No.
Description
Edwards Model EO50/60 Diffusion Pump,
90 volts (for Agilent MSD) no fan
Edwards Model EO50/60 Diffusion Pump,
180 volts (for Agilent MSD) no fan
Electron Multiplier
for 5973 & 5975
MSD
Electron multipliers for the
HP5973 MSD are available from
Burle*, ETP and DeTech. Each of
the multipliers listed below comes
with a manufacturer's warranty
and includes installation instruc-
tions. See the electron multiplier
section of these catalog for more
details on each of the multipliers
listed below
Baseplate O-Ring for 5973
Brown viton O-ring is a direct replacement
for the Agilent O-ring (Part #0905-1242)
Part No.
Description
DeTech EM Horn for HP5971/72/73/75
Complete EM for HP5973
Burle* 5900 Magnum
Part No.
Description
Repair of HP 5973 Entrance Lens Pin
Repair of HP5973 Ion Focus Pin
Part No.
Description
Agilent 5972/5973/5975 Ion Gauge Tube
Agilent 5972/5973/5975 Ion Gauge Controller
Agilent 5972/5973/5975 Ion Gauge Cable
DeTech
Part No.
Description
5973 Filament Assembly, CI - 2pk.
5973 Filament Assembly, EI
5975 Filament Assembly
5973 Filament Repair
Quantity of 6 or more
The Mini Ion Gauge Tubes for the Agilent 5972/5973 MSD are available from SIS. The controller electronics and cable are available
if you did not buy this device with your instrument and now wish to upgrade.
Part No.
Description
10.75" x 4/8" Viton
base plate seal
*When "Burle" is indicated, it is intended to imply "Photonis USA, Inc."
tip...