SECTION I - GENERAL INFORMATION
MANUFACTURER: Inland Vacuum Industries, 35 Howard Avenue, Churchville, NY 14428
EMERGENCY TELEPHONE: DAYS:(716)293-3330 EVENINGS: (803)366-0862
DATE PREPARED: 9/19/91
PRODUCT CODE: 404900
PRODUCT NAME: Inland FF-10
NPFA RATING:
Flammability: 1 Health Hazard: 0 Reactivity: 0 Special Hazard: NONE
CAS NUMBER: 64742-65-0
CHEMICAL FORMULA: (CH2)n 20 =< n =< 40
GENERIC NAME: Solvent refined neutral paraffinic oil
TRADE NAMES AND SYNONYMS: Inland 99, Savant SFF-1
SECTION II - REGULATED INGREDIENTS
(29 CFR 1910. 1200)
REGULATED MATERIALS AT CONCENTRATION OF 1% (WT) OR GREATER
NO HAZARDOUS INGREDIENTS. MATERIAL IS 100% NEUTRAL PARAFFINIC OIL. MATERIAL HAS BEEN SUBJECT TO SEVERE SOLVENT REFINING.
SECTION III - HEALTH HAZARD DATA
POSSIBLE ENTRY ROUTES: Ingestion, Inhalation of oil mists
TARGET ORGANS: None Known
EFFECTS OF OVEREXPOSURE:
ACUTE EFFECTS: Exposure to oils mists may cause nausea and eye irritation. Detailed studies have not been made, but material is not expected to be dermatitic or a sensitizer.
CHRONIC EFFECTS: None known.
FIRST AID PROCEDURES: Skin - wash with soap and water. Eyes - flush with water. Get medical attention. Ingestion - Contact a physician! Small amounts in mouth may be washed out.
SECTION IV - FIRE AND EXPLOSION HAZARD
FLASH POINT: > 213 degrees C METHOD USED: Cleveland Open Cup EXPLOSIVE LIMITS: LOWER: Unknown UPPER: Unknown
EXTINGUISHING MEDIA: Water fog, chemical foam or carbon dioxide.
SPECIAL FIREFIGHTING PROCEDURES: Wear breathing gear when fighting fires in enclosed spaces; incomplete combustion of this material produces carbon monoxide!
UNUSUAL FIRE AND/OR EXPLOSION HAZARDS: None.
SECTION V -PHYSICAL PROPERTIES
PHYSICAL STATE: Liquid VAPOR PRESSURE: < .001 Torr @ 25 degrees C BOILING POINT: >200 degrees C EVAPORATION RATE(ether = 1): Nil VAPOR DENSITY: Approximately 14 WT % VOLATILES: Nil SPECIFIC GRAVITY: 0.85 VISCOSITY: 29 cst @ 40 degrees C SOLUBILITY IN WATER: Nil APPEARANCE: Pale yellow, viscous liquid with faint petroleum odor.
SECTION VI - REACTIVITY DATA
STABILITY: Material is stable
CONDITIONS TO AVOID: Continuous exposure to temperatures > 200 degrees C
INCOMPATIBILITY (MATERIALS TO AVOID): Strong Oxidizers
HAZARDOUS DECOMPOSITION PRODUCTS: Incomplete combustion may produce carbon monoxide.
SECTION VII - RELEASE PROCEDURES
PROCEDURE TO BE FOLLOWED IN EVENT OF RELEASE: Small spills may be wiped up with a rag. Large spills should be picked up immediately with an absorbent.
PROCEDURES FOR PROPER WASTE DISPOSAL: Proper waste disposal procedures are dependent on the product's end-use. Check applicable Federal, State and Local covering treatment, storage and disposal of your process effluents.
SECTION VIII - SPECIAL PROTECTION INFORMATION
RESPIRATORY PROTECTION: See notes on ventilation below.
PROTECTIVE GLOVES: Yes - made of oil-impermeable rubber.
SAFETY GLASSES/GOGGLES: Yes - glasses should have side shields.
OTHER PROTECTIVE EQUIPMENT: None should be required under normal use.
VENTILATION: US Gov't 8 hr TWA limit for exposure to oil mists is 5 mg per cubic meter.
LOCAL EXHAUST: As required to meet limit shown above.
MECHANICAL EXHAUST: As required to meet limit shown above.
SECTION IX - SPECIAL PRECAUTIONS
SPECIAL HANDLING PRECAUTIONS: None
SPECIAL STORAGE PRECAUTIONS: None
ADDITIONAL INFORMATION: NFPA Class III B material
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.