SECTION I - PRODUCT IDENTIFICATION
Sigma Chemical Company Phone: 800-325-3010
PO Box 14508 Phone Outside USA & Canada:
St. Louis, Missouri 63178 USA Collect 314-771-5750
Fax: 800-325-5052
Trade Name: FABTGL Telex: 910-761-0593
Chemical Identification
CATALOG #: M1753 NAME: A-MONOTHIOGLYCEROL
SECTION II - COMPOSITION/INFORMATION ON INGREDIENTS
CAS #: 96-27-5 MF: C3H802SI EC No: 202-495-0
SYNONYMS:
GLYCEROL, 1-THIO- * 1-MERCAPTOGLYCEROL * l-MERCAPTO-2, 3-PROPANEDIOL * 3-MERCAPTO-1,2-PROPANEDIOL * MONOTHIOGLYCERIN * MONOTHIOGLYCEROL * ALPHA-MONOTHIOGLYCEROL * THIOGLYCERIN * THIOGLYCEROL ALPHA- THIOGLYCEROL * 1-THIOGLYCEROL * THIOVANOL * USAF B-40 USAF CB-37 *
SECTION III - HAZARDS IDENTIFICATION
LABEL PRECAUTIONARY STATEMENTS:
TOXIC (USA DEFINITION)
HARMFUL (EUROPEAN DEFINITION)
HARMFUL BY INHALATION IN CONTACT WITH SKIN AND IF SWALLOWED. CAUSES SEVERE IRRITATION.
STENCH.
IN CASE OF CONTACT WITH EYES, RINSE IMMEDIATELY WITH PLENTY OF WATER AND SEEK MEDICAL ADVICE
WEAR SUITABLE PROTECTIVE CLOTHING.
SECTION IV - FIRST AID MEASURES
IN CASE- OF CONTACT, IMMEDIATELY FLUSH EYES OR SKIN WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES WHILE REMOVING CONTAMINATED CLOTHING AND SHOES.
ASSURE ADEQUATE FLUSHING OF THE EYES BY SEPARATING THE EYELIDS WITH FINGERS.
IF INHALED, REMOVE TO FRESH AIR. IF NOT BREATHING GIVE ARTIFICIAL RESPIRATION. IF BREATHING IS DIFFICULT, GIVE OXYGEN.
IF SWALLOWED, WASH OUT MOUTH WITH WATER PROVIDED PERSON IS CONSCIOUS. CALL A PHYSICIAN.
DISCARD CONTAMINATED CLOTHING AND SHOES.
SECTION V - FIRE FIGHTING MEASURES
EXTINGUISHING MEDIA:
CARBON DIOXIDE, DRY CHEMICAL POWDER OR APPROPRIATE FOAM.
SPECIAL FIREFIGHTING PROCEDURES:
WEAR SELF-CONTAINED BREATHING APPARATUS AND PROTECTIVE CLOTHING TO PREVENT CONTACT WITH SKIN AND EYES.
USE WATER SPRAY TO COOL FIRE-EXPOSED CONTAINERS.
UNUSUAL FIRE AND EXPLOSIONS HAZARDS:
EMITS TOXIC FUMES UNDER FIRE CONDITIONS.
SECTION VI - ACCIDENTAL RELEASE MEASURES
EVACUATE AREA
WEAR SELF-CONTAINED BREATHING APPARATUS, RUBBER BOOTS AND HEAVY RUBBER GLOVES.
COVER WITH AN ACTIVATED CARBON ADSORBENT, TAKE UP AND PLACE IN CLOSED CONTAINERS. TRANSPORT OUTDOORS.
VENTILATE AREA AND WASH SPILL SITE AFTER MATERIAL PICKUP IS COMPLETE.
SECTION VII - HANDLING AND STORAGE
REFER TO SECTION VIII
SECTION VIII - EXPOSURE CONTROLS/PERSONAL PROTECTION
WEAR APPROPRIATE NIOSH/MSHA-APPROVED RESPIRATOR, CHEMICAL-RESISTANT GLOVES, SAFETY GOGGLES, OTHER PROTECTIVE CLOTHING.
USE ONLY IN A CHEMICAL FUME HOOD.
SAFETY SHOWER AND EYE BATH.
FACESHIELD (8 INCH MINIMUM)..
DO NOT BREATHE VAPOR.
DO NOT GET IN EYES, ON SKIN, ON CLOTHING.
AVOID PROLONGED OR REPEATED EXPOSURE.
WASH THOROUGHLY AFTER HANDLING.
TOXIC.
SEVERE IRRITANT.
KEEP TIGHTLY CLOSED.
STENCH.
STORE IN A COOL DRY PLACE.
SECTION IX - PHYSICAL AND CHEMICAL PROPERTIES
APPEARANCE AND ODOR:
VISCOUS COLORLESS LIQUID
BOILING POINT: 118 C/5MM.
FLASHPOINT >230, > 109C
SPECIFIC GRAVITY: 1.295
SECTION X - STABILITY AND REACTIVITY
INCOMPATIBILITIES:
BASES
OXIDIZING AGENTS
REDUCING AGENTS
ALKALI METALS
HAZARDOUS COMBUSTION OR DECOMPOSITION PRODUCTS:
TOXIC FUMES OF:
CARBON MONOXIDE, CARBON DIOXIDE
SULFUR OXIDES
HYDROGEN SULFIDE GAS
SECTION XI - TOXICOLOGICAL INFORMATION
ACUTE EFFECTS:
HARMFUL IF SWALLOWED, INHALED, OR ABSORBED THROUGH SKIN.
CAUSES SEVERE IRRITATION,
HIGH CONCENTRATIONS ARE EXTREMELY DESTRUCTIVE TO TISSUES OF THE MUCOUS MEMBRANES AND UPPER RESPIRATORY TRACT. EYES AND SKIN.
SYMPTOMS OF EXPOSURE MAY INCLUDE BURNING SENSATION, COUGHING, WHEEZING, LARYNGITIS, SHORTNESS OF BREATH, HEADACHE, NAUSEA AND VOMITING.
EXPOSURE CAN CAUSE: NAUSEA, HEADACHE AND VOMITING.
RTECS NO: TY8140000
l,2,-PROPANEDIOL, 3-MERCAPTO-
TOXICITY DATA:
IPR-RAT LD50:390 MG/KG JPETAB 97,349,49 IPR-MUS LD50:340 MG/KG JPETAB 97,349,49 IVN-CAT LD50:220 MG/KG JPETAB 97,349,49 IVN-RBT LD50:250 MG KG JPETAB 97,349,49
TARGET ORGAN DATA:
SENSE ORGANS AND SPECIAL SENSES (LACRIMATION)
BEHAVIORAL (CONVULSIONS OR EFFECT ON SEIZURE THRESHOLD)
BEHAVIORAL (ATAXIA)
PATERNAL EFFECTS (SPERMATOGENESIS)
EFFECTS ON FERTILITY (MALE FERTILITY INDEX)
ADDITIONAL INFORMATION:
ORL-RAT LD50:673 MG/KG
SKN-RAT LD50:699 MG/KG
ONLY SELECTED REGISTRY OF TOXIC EFFECTS OF CHEMICAL SUBSTANCES (RTECS) DATA IS PRESENTED HERE. SEE ACTUAL ENTRY IN RTECS FOR COMPLETE INFORMATION.
SECTION XII - ECOLOGICAL INFORMATION
DATA NOT YET AVAILABLE.
SECTION XIII - DISPOSAL CONSIDERATIONS
THE MATERIAL SHOULD BE IGNITED IN THE PRESENCE OF SODIUM CARBONATE AND SLAKED LIME (CALCIUM HYDROXIDE). THE SUBSTANCE SHOULD BE MIXED WITH VERMICULITE AND THEN WITH THE DRY CAUSTICS, WRAPPED IN PAPER AND BURNED IN A CHEMICAL INCINERATOR EQUIPPED WITH AN AFTERBURNER AND SCRUBBER.
OBSERVE ALL FEDERAL, STATE AND LOCAL ENVIRONMENTAL REGULATIONS.
SECTION XIV - TRANSPORT INFORMATION
CONTACT ALDRICH CHEMICAL COMPANY FOR TRANSPORTATION INFORMATION.
SECTION XV - REGULATORY INFORMATION
EUROPEAN INFORMATION:
Harmful
R 20/21/22
Harmful by inhalation, in contact with skin and if swallowed.
S 26
In case of Contact with eyes, rinse immediately with plenty of water and seek medical advice
S 36
Wear suitable protective clothing.
REVIEWS, STANDARDS, AND REGULATIONS:
NOHS 1974: HZD 83967: NIS 3: TNF 213: NOS 5: TNE 1912
NOES 1983: HZD 83967: NIS 19: TNF 1453: NOS 23; TNE 16551: TFE 6744
EPA TSCA CHEMICAL INVENTORY, JUNE 1993
SECTION XVI - OTHER INFORMATION
THE ABOVE INFORMATION IS BELIEVED TO BE CORRECT BUT DOES NOT PURPORT TO BE ALL INCLUSIVE AND SHALL BE USED ONLY AS A GUIDE. ALDRICH SHALL NOT BE HELD LIABLE FOR ANY DAMAGE RESULTING FROM HANDLING OR FROM CONTACT WITH THE ABOVE PRODUCT. SEE REVERSE SIDE OF INVOICE OR PACKING SLIP FOR ADDITIONAL TERMS AND CONDITIONS OF SALE.
COPYRIGHT 1995 SIGMA CHEMICAL C0., INC.
LICENSE GRANTED TO MAKE UNLIMITED PAPER COPIES FOR INTERNAL USE ONLY.
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.