This item also available new from S.I.S.
If the only problem is that the GLT welds to the Swagelok fittings are leaking, they can be cleaned and vacuum welded to seal the leaks. After repair, the dual transfer line is helium leak checked for good vacuum seals at all joints and welds. If the GLT lines are damaged they will need to be replaced as described in repair REP331 .
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP33W | Reweld dual transfer line fittings | EA | 0.2 | 0(#) | $82.70 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Replacement Of Dual Transfer Line Fittings
Dual Transfer Line assembly fittings can be replaced if they become damaged, or if the size or type of fitting needs to be changed. GLT lines must also be replaced at the same time as the fittings. The prices below include replacement of fittings and both GLT lines. Fitting size can be changed to other sizes if requested. For example, two 1/16" fittings can be installed for dual capillary operation.
| UOM=EA | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| REP333 | Replace one or both Swagelok fittings and GLT lines on dual transfer line | 2 | 0(#) | $303.00 | |
| REP334 | Replace one or both Swagelok fittings and GLT lines on dual transfer line for capillary feedthru operation | 2 | 0(#) | $303.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
If either of the GLT lines are damaged or clogged, they will both need to be replaced. Our procedure includes complete disassembly of the movable transfer line, cleaning and replacement of all GLT lines. This is followed by vacuum welding all joints to fittings. After repair the entire assembly is helium leak checked to assure good vacuum seals of all joints and welds. The Swagelok fittings can also be replaced as described in repair REP333.
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP331 | Dual transfer line GLT replacement | EA | 2 | 0(#) | $209.50 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Repair Of Dual Transfer Line For Capillary Feedthru Operation
By changing the curvature of the capillary line bends and increasing the inside diameter, it is possible to feed fused silica tubing completely through the dual transfer line assembly.
This repair is identical to repair REP331 described above except that both GLT lines have an internal diameter of 0.7mm and the radius of curvatures is increased, enabling the fused capillary tubing to easily pass through the glass lined tubing. Both GLT lines are replaced and vacuum welded to the fitting. After repair the entire assembly is helium leak checked to assure good vacuum seals at all welds. For dual capillary operation, the ¼' Swagelok fitting can be replaced with a 1/16" Swagelok fitting. See repair REP334.
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| REP332 | Replace both GLT lines of dual transfer line assembly for capillary feedthru operation. | EA | 2 | 0(#) | $209.50 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.