SIS Catalog Online >> Page Number: [ previous page next page ]
[Table of Contents > Liquid Chromatography | Index] Zoom: [ Printable PDF]
Ordering: Click part number to add to shipping cart. Contact your Local Dealer for non-US prices.
www.sisweb.com/catalog/08/E45
E45
New Objective Electrospray Tips
Scientific Instrument Services, Inc.
TM
FAX: 908-806-6631
Part Number
Tubing OD
Flow Range
Tubing Length
Pieces per
Tip ID (µm)
µL/min
(cm)
Pkg.
MT320-50-35-5
320/50
0.2-1.5
3.5
5
MT320-50-5-5
320/50
0.2-1.5
5
5
MT320-100-35-5
320/100
0.5-2.0
3.5
5
MT320-100-5-5
320/100
0.5-2.0
5
5
Part Number
Tubing OD/
Tip OD
Tip OD
Tubing Length
Flow Range
Pieces Per
Tip ID (µm)
(µm)
Typical (µm)
(cm)
(µl/min)
Pkg.
Coated Fused-silica TaperTip - Patent Pend. multilayer conductive coating applied to the tip end.
TT360-100-50-CE-5
360/100
120-160
140
50
0.4 - 3
5
TT360-75-50-CE-5
360/75
100-130
115
50
0.3 - 2
5
TT360-50-50-CE-5
360/50
70-90
80
50
0.2 - 1
5
TT360-20-50-CE-5
360/20
40-60
50
50
0.2 - 0.5
5
TT150-50-50-CE-5
150/50
60-80
70
50
0.2 - 1
5
Uncoated Fused-silica TaperTip
TT360-100-50-N-5
360/100
120-160
140
50
0.4 - 3
5
TT360-75-50-N-5
360/75
100-130
115
50
0.3 - 2
5
TT360-50-50-N-5
360/50
70-90
80
50
0.2 - 1
5
TT360-20-50-N-5
360/20
40-60
50
50
0.2 - 0.5
5
TT150-50-50-N-5
150/50
60-80
70
50
0.2 - 1
5
Distal Coated Fused-silica TaperTip
TT360-100-50-D-5
360/100
120-160
140
5
0.4 - 3
5
TT360-75-50-D-5
360/75
100-130
115
5
0.3 - 2
5
TT360-50-50-D-5
360/50
70-90
80
5
0.2 - 1
5
TT360-20-50-D-5
360/20
40-60
50
5
0.2 - 0.5
5
*Frit material is borosilicate glass.
Typical range of Taylor cone stability with a spray solution of 75% methanol, 2% Acetic acid, using no sheath or curtain gas. Due to experimental
variability actual performance may differ considerably from the stated value(s).
Metal TaperTips
TaperTip
TM
- tips with an external taper only
-
Operation at higher flow rates ( 0.3 to 1 µl
than PicoTips
TM
-
Polyimide coating extends to the taper region
-
Mechanically durable tips - better withstands
contact & handling
-
Reduced particle clogging
-
Stock number prefix: TT
-
Available in a variety of tip diameters, up to 1 m long
Fused Silica TaperTips
tip...
Page Number: [ previous page next page ]
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call/e-mail/FAX us, or type your comments below.
Name/organization:
Email: Phone/fax:
Regular business hours are 8:00 AM to 5:30 PM EST, M-F.
E-mail replies are normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL: contact us WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551.
© 1996-2008 Scientific Instrument Services, Inc. [Trademarks]