Mass Spec | Gas Chrom | Liquid Chrom | Thermal Desorption | Vacuum Systems | General Lab | Cleaning | Software

Thermal Desorption System and Accessories

SIS Short Path Thermal Desorption System

Accessory Equipment

  • GC Cryo-Trap - The GC Cryo-Trap is used to cryo-focus volatiles at the front of the GC column in a narrow band for subsequent heating and release. Two models are available (CO2 and Liquid Nitrogen). The GC Cryo-Trap is recommended for optimum results for the trapping of the lower molecular weight volatiles.
  • Thermal Desorption Conditioning System - Used to bake out and condition desorption tubes and needle transfer lines at high temperature with gas flow. Assures that no contamination originates from your desorption tubes and needles. A 6 Tube Conditioning Oven and a 24 Tube Conditioning Oven are available.
  • Sample Collection System - Used to purge volatiles off 1 to 20 gram size solid samples onto adsorbent resin traps for subsequent analysis via the thermal desorption system. Used for the analysis of high water content solid samples or when very low detection levels of volatiles is required.
  • SIS Purge and Trap System - Used to Purge Volatiles from liquid and solid samples onto adsorbent resin traps. This low cost system is ideal for volatiles in beverages, water and other samples requiring a sample between 1.o ml and 25 ml to be used.
  • Wheaton Purge and Trap System - Similar to the above but two size vessels are available for larger samples (100 ml and 1.0 liter). Used when lower levels of analysis are required and for the analysis of plant and flower material.
  • Air Sampling Pump - A small, field portable personal sampling pump for the collection of volatiles from air samples onto adsorbent resin traps. This pump can handle the backpressure needed for packed thermal desorption tubes and can be set to accurately and reproducibility pump samples at flow rates from 5 to 200 ml per minute.
  • Thermal Desorption Sample Loader - Used to inject liquid samples or internal standards in solution onto the adsorbent resin trap. Assures total delivery of the sample to the adsorbent resin without any loss due to evaporation.
  • Gillibrator Air Flow Calibration System - A primary air flow calibration system to calibrate sysems for both positive and negative flows.

Accessories and Supplies

Technical Support

Tenax® is a registered trademark of Buchem BV.
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call/e-mail/FAX us, or type your comments below.
Name/organization:
Email: Phone/fax:
Regular business hours are 8:00 AM to 5:30 PM EST, M-F.
E-mail replies are normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL: contact us WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551.
© 1996-2008 Scientific Instrument Services, Inc. [Trademarks]