Scientific Instrument Services, Inc.  Supplies and Services for Mass Spectrometers, Gas Chromatographs, and Liquid Chromatographs.

The NIST 08 Mass Spectral Library (NIST/EPA/NIH)--New 2008 Version

Figure: EI spectra, structure, and corresponding data for a sample compound in the NIST database.


Four-page brochure of NIST 08 (PDF)

--The fully-evaluated, most widely used mass spectral reference library. Compiled by the National Institute of Standards and Technology (NIST).

Summary: The NIST 08 mass spectral database, the successor to the NIST 05, is a fully evaluated collection of electron ionization (EI) mass spectra. It also contains MS/MS spectra and GC data. It is the product of a two decade, comprehensive evaluation and expansion of the world's most widely used mass spectral reference library by a team of experienced mass spectrometrists in which each spectrum was examined for correctness.

NIST Components

NIST is not just a mass spectral library. It contains these components:

Libraries are formatted the binary format suitable for use alone or by the NIST MS Search software (and AMDIS). Additional instrument-specific formats (e.g. Agilent ChemStation) are available separately to permit library searching directly within your GC/MS or LC/MS data system.

With each purchase, we ship a CD (installs software, libraries, and documentation) and a printed manual.

Online Search

To check for compounds in the NIST 08, you may search names of compounds online.

Summary Statistics

Statistics for NIST 08 and earlier versions are given below.

  NIST 08 NIST 05 NIST 02
EI Spectral Library:
Number of EI Spectra
220,460(*)
(with separable collection of 717 spectra of 672 salts)
190,825(*) 174,948
Number of Unique Compounds 192,108 163,198 147,198
Kovats Retention Index 224,038 index values for 21,847 compounds in the EI library, now on both polar and non-polar columns. 121,112 index values for 25,893 compounds, 12,452 of which exist in the EI Library, on only non-polar columns. NONE
MS/MS Library 14,802 spectra of 5,308 precursor ions (3,898 cations and 1,410 anions). 5,191 spectra of 1,943 different ions (1,671 positive and 341 negative) NONE
NIST MS Search software v. 2.0f (2008-08) v. 2.0d (2005-04) v. 2.0a (2002-07)
AMDIS software v. 2.65 (2006-12) v. 2.62 (2005-03) v. 2.1 (2002-07)
Release Date August 2008 June 2005 July 2002

(*) plus quality improvements

See also What's New in NIST 08.

Electron Ionization (EI) mass spectral library

This is a "fully evaluated" collection of electron ionization (EI) mass spectra. It is the product of a two decade, comprehensive evaluation and expansion of the world's most widely used mass spectral reference library by a team of experienced mass spectrometrists in which each spectrum was examined for correctness. This has lead to thousands of selections, deletions and modifications to produce an optimal reference library of compound identification by spectrum matching and library searching. Each spectrum has been carefully evaluated, and all decisions regarding selection or deletion were made only after agreement of two experienced mass spectral evaluators, as described in presentations at major conferences. While computer methods assisted in finding chemical identification errors and inconsistencies, and revealed certain varieties of mass spectral errors, manual interpretation was the principal basis for this evaluation effort.

The Electron Ionization (EI) mass spectral library consists of 220,460 spectra of 192,108 unique compounds, most of which include chemical structures and related data.

Besides spectra, typical data include name, formula, molecular structure (.mol), molecular weight, CAS number, contributor name, list of peaks, synonyms, and estimated retention index.

Name: 1-Decanol
Formula: C10H22O
MW: 158 CAS#: 112-30-1 NIST#: 227969 ID#: 17833 DB: mainlib
Other DBs: Fine, TSCA, RTECS, HODOC, NIH, EINECS, IRDB
Contributor: Japan AIST/NIMC Database- Spectrum MS-NW-4441
10 largest peaks: 
55 999 |43 988 |56903 |70894 |41776 |
69 725 |83 549 |57462 |84397 |42371 |
Synonyms: 
1.Decyl alcohol
2.n-Decan-1-ol
3.n-Decanol
4.n-Decyl alcohol
5.Alcohol C10
6.Alfol 10
7.Capric alcohol
8.Caprinic alcohol
9.Decanol
...22 other names...

Estimated non-polar retention index (n-alkane scale): 
Value: 1258 iu
Confidence interval (Alcohols):  41(50%) 176(95%) iu

The NIST EI Library focuses on:

Here is a breakdown by mass:

The best quality spectra are placed in the Main Library; and good-quality, alternate spectra are provided in the Selected Replicates Library.

NIST 08 includes a separable collection of 717 spectra of 672 salts and low-volatile substances not expected to be measurable by GC/MS (nist_salts). Here's a breakdown by mass:

To check whether certain compounds or classes of compounds exist within the NIST 08 database, you may do an online search of compounds in the NIST 08 database.

NIST spectra have been obtained from thousands of sources. Major sources include

# Spectra, Name
29410 A.A.Kutin, Moscow, Russia
28787 Zaikin V.G., Borisov R.S., L.N.Kulikova, TIPS RAS / RPFU / Russian
..... Friendship University / Topchiev Inst.Petrochem.Synth., Moscow, Russia
26548 Chemical Concepts
13336 Japan National Institute of Advanced Industrial Science and Technology (AIST)
..... / National Institute of Materials and Chemical Research (NIMC)
..... Database- Spectrum MS-IW-1026/MS-NW-9250
9594  NIST Mass Spectrometry Data Center
7657  Div. of Experiment Therapeutics, Walter Reed Army Institute of Research
..... (WRAIR), Washington DC
5586  National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK),
..... National Institutes of Health (NIH), Bethesda, MD
4163  A.T.Lebedev, Moscow State University
2683  ASES Database, Dalian Institute, P.R. China
2376  Carl Djerassi, Dept. Chemistry, Standford University, Stanford Calif.
2360  Asinex Ltd, Moscow, Russia
2205  D.Henneberg, Max-Planck Institute, Mulheim, Germany
2182  Institute of Organic Chemistry, Novosibirsk, Russia
1789  A.Mazepa, Phys.-Chem.Institute, Odessa, Ukraine
1528  Humboldt-Universitat zu Berlin, Department of Chemistry, Analytical Group
1481  A.Pleshkova, Nesmeyanov Inst.Org.Elem.Cpds, Moscow
1091  Organic Synthesis Lab, MSU, Moscow
1066  William W. Christie, Mylnefield Lipid Analysis, Invergowrie, Dundee, Scotland, UK

MS/MS Library

Most of the MS/MS spectra have been measured on ion trap and collision cell instruments using electrospray ionization, although spectra from a number of other instrument types and ionization methods are represented. Spectra have been provided by contributors, measured at NIST and extracted from the literature. In view of the relatively small size of the library, it is intended primarily to serve as a 'starter set'. It also documents spectrum variations between instruments classes at different conditions. We have found that at sufficiently high signal-to-noise measurement conditions, modern instruments are capable of providing very reproducible, library searchable spectra. While collision energy can be an important variable, spectra varies in an understandable way depending on compound and instrument class and conditions. This Library is provided in formats equivalent to the Electron Ionization Library but with new fields added to describe the instrument and analysis conditions. A small number of MS1 spectra are also included for reference purposes. These generally contain the ions used for MS/MS.

The search software permits the examination of all MS/MS spectra - these are available as a selectable library, with the name 'nist_msms'. A new MS/MS tab has been added to the MS Search Software to view that data.

Further information on the MS/MS sub-library:

Gas Chromatography (GC) Data Library

Gas phase retention data for compounds common to the EI and NIST Retention Data collection are provided with links to the EI library. This involves 192,108 Kovacs indices and corresponding GC column conditions and literature citations for 21,847 compounds, an increase of over 50% from the previous version. Data include both non-polar and polar columns. Most values were abstracted from the open literature and then compared to replicate values (average of 10 per compound) and estimates to find and remove errors. We also continue to provide estimates of retention indices for most compounds in the library using an extension of a method developed earlier for boiling points [2-3].

GC data includes

Here's typical GC data included for a compounds (decanol):

Estimated non-polar retention index (n-alkane scale): 
Value: 1258 iu
Confidence interval (Alcohols):  41(50%) 176(95%) iu

Retention index 
1. Value: 1256 iu
Column Type: Capillary
Column Class: Standard non-polar
Active Phase: CP-Sil PONA GB
Column Length: 100 m
Carrier Gas: He
Column Diameter: 0.25 mm
Phase Thickness: 0.25 um
Data Type: Linear RI
Program Type: Ramp
Start T: 140 C
End T: 230 C
Heat Rate: 5 K/min
Start Time: 10 min
End Time: 25 min
Source: Cunicao, M.M.; Lopes, A.R.; Ccco, L.C.; Yamamoto, C.I.;
Plocharski, R.C.B.; Miguel, M.D.; Junior, A.G.; Auer, C.G.; Miguel,
O.G., Phytochemical and antibacterial evaluation of essential oils
from Ottonia Martiana Miq. (Piperaceae), J. Braz. Chem. Soc., 18(1),
2007, 184-188.

...152 additional retention index citations follow...

The GC data is useful not only for the GC retention index values but also for the GC column conditions and cited literature that goes with it.

References:
[1]. Babushok, V.I., Linstrom, P.J., Reed, J.J., Zenkevich, I.G., Brown, R.L., Mallard, W.G., Stein, S.E., Development of a database of gas chromatographic retention properties of organic compounds. J.Chromatog. A, 2007, 1157, 414-421.
[2]. Stein, S.E., Brown, R.L. Estimation of normal boiling points from group contributions. J.Chem.Inform.Comput.Sci., 1994, 34, 581-587.
[3]. Stein, S.E., Babushok, V.I., Brown, R.L., Linstrom, P.J., Estimation of Kovats retention indices using group contributions. J.Chem.Inf.Modeling, 2007, 47, 975-980.

NIST MS Search Software


Figure: NIST MS Search software

The updated, full-featured NIST MS Search Program for Windows has a full range of integrated tools.  The new updated version of this widely used, full-featured software is designed for identifying compounds from their mass spectra and for exploring mass spectral libraries.  It also contains tools for deconvoluting gas/liquid chromatograms and interpreting mass spectra.

Overview

This software provides a flexible means of accessing data in the NIST and User libraries including:

Windows Organization

When the program is first started, seven tiled windows appear on the screen (the Desktop), each with its own data and behavior.  The behavior of any Window may be modified by making it active (clicking on it) and then pressing the AdjustWin button at the bottom of the Desktop.  As you become familiar with program operation, you may wish to change the dimensions of some Windows or even close some of them to create a custom Desktop.  When the program is restarted, it will begin with the most recent Desktop.  To save a window-arrangement Desktop for future use, select Desktop from the Menu Bar and then Save As from the resulting Menu.  Prior Desktops may be restored using one of the predefined names or your own name.  Such arrangements describe the geometry and type of information shown in each Window, not the actual data contained in it.  To restore a previous hit list, select it from the list at the top of the Hit List Window.

Library Searching - Identify unknown compounds and substructures using fully documented and optimized procedures, or search by a wide range of compound and spectral properties.

Library Building - Maintain your own libraries, add your own chemical structures and search using the same optimized procedures developed for NIST.

Flexible User Interface - Set multiple Desktop configurations with up to seven independently configured windows to examine search results and match your needs.

Use with Your Instrument Data Systems - Direct transfer between a number of commercial data systems and the NIST Search Program.

Adding User-Drawn Structures
Users may import their own chemical structures with selected user spectra.  This is done in the Tools/Librarian section of the program by connecting a user-drawn structure in standard MOL-file format with a user spectrum.  Such structure-drawing programs are widely  available (for example, ISIS/Draw may be freely downloaded from http://www.mdli.com/prod/freesw.html).  As before, if a user spectrum is given its CAS registry number and the Main Library has a structure for it, this structure will automatically be shown with user spectra unless the user has attached an imported structure to the spectrum.

Aids for Automation and Reporting
A variety of methods for automated searching and reporting of results are available.  From the File menu selection, if Print automation is on, printing will follow each library search.  A set of print options is also available from the �User Search Options� Window (select Search, then User spectrum).  This is of particular use when using this NIST Program with other data acquisition programs.

Automated Mass Spectrometry Deconvolution and Identification System (AMDIS)

The AMDIS software extracts pure component spectra from complex GC/MS or LC/MS data files and searches against specialized libraries or the NIST 05 library.  This module was developed at the national Institute of Standards and Technology (NIST) for the critical task of verifying a major international treaty, the Chemical Weapons Convention. After two years of development and extensive testing it is now being made available to the general analytical chemistry community. AMDIS can operate as a "black box" chemical identifier, displaying all identifications that meet a user-selectable degree of confidence. Identification can be aided by internal standards and retention times. Libraries can be built directly from analyzed data files or from spectra in the NIST/EPS/NIH Database. AMDIS can also serve as a preprocessing tool for the GC/MS data files, automatically performing noise reduction for all components. It permits traditional library searching for any selected component. A flexible interface is provided to assist the analysis of complex matrices.

Included as a separate utility, AMDIS attempts to reconstruct original mass spectra for individual components in arbitrarily complex GC/MS and LC/MS reconstructed total ion current (RTIC) chromatograms; and, if a target library is provided, can directly identify target compounds.  AMDIS is especially useful when an RTIC chromatographic peak represents multiple components.  Regardless of each component's concentration, pure mass spectra are deconvoluted for analyses.  AMDIS was developed by NIST for the Defense Weapons Agency (Department of Defense) for verifying compliance with a major international treaty (Chemical Weapons Convention) ratified by the United States Senate in 1997.  In order to meet the rigorous requirements for this purpose, AMDIS was tested against more than 30,000 GC/MS data files accumulated by the EPA Contract Laboratory Program without a single false-positive for the target set of known chemical warfare agents.  While this level of reliability may not be required for all laboratories, this shows the degree to which the algorithms have been tested.

AMDIS has been designed to reconstruct "pure component" spectra from complex RTIC chromatograms even when components are present at trace levels.  For this purpose, observed chromatographic behavior is used along with a range of noise-reduction methods.  AMDIS is distributed with specialized libraries (environmental, flavor and fragrance, and drugs and toxins), that were derived from the NIST Library.  AMDIS has a range of other features, including the ability to search the entire NIST Library with any of the spectra extracted from the original data file.  It can also employ retention index windows when identifying target compounds and can make use of internal and external standards maintained in separate libraries.  A history list of selected performance standards is also maintained.

As of version 2.65, AMDIS reads data files in the following formats:

Additional NIST MS Tools: Mass Spec Interpreter



Figure: NIST MS interpreter

This utility enables the user to examine neutral losses, isotope patterns and possible chemical formulas along with computer assisted chemical structure/spectral analysis. Starting with Version 1.5, the program has offered a unique means of interpreting spectra of compounds not identified in the Library by the User spectrum search.  This is most useful when no acceptable matching spectra are found in a User spectrum search of the NIST Library.  At this point, by selecting Substructure Information from the Tools menu, the current hit list is analyzed and statistical information on the composition of the unknown is derived from the hit list.  For instance, the probability that any of a range of substructures are present or absent are listed (phenyl, acid, ester group, double bond, heteroatom, etc.) along with an estimate of the molecular weight and chlorine/bromine content (the latter is based only on the spectrum itself).

This tool was developed to aid NIST evaluators in their analysis of mass spectra.  In one integrated program, it permits a wide range of calculations on a mass spectrum using--if available--a proposed chemical structure.  Spectra and structures are associated in the library facility of the Windows Search Program discussed above, and the program is activated from the Tools menu.  Peaks in the spectrum originating as a logical fragment of the molecule are marked, and corresponding fragments may be highlighted.  It also allows the analyst to keep track of important neutral losses, both from the parent or a derived ion, and to readily compute possible formulas for any peak or neutral loss and isotopic patterns as desired. Observed isotopic clusters can be compared to theoretical predictions subject to a number of user-specified constraints.



Figure: NIST Formula and Isotopic Pattern Generator

New in NIST 08

NIST 08 made the following major changes since NIST 05.

Electron Ionization (EI) Library: The new library consists of 220,435 spectra of 192,262 compounds an increase of 15% over the previous version. NIST has, at the same time, continued to improve overall library quality by re-measuring and reexamining thousands of spectra. For example, it has been provided consistent identification for hundreds of salts and created a separable collection of low-volatile substances not expected to be measurable by GC/MS (717 spectra of 672 salts). Thousands of spectra of common derivatives and contaminants measured at NIST or by close collaborators have been added. As before, all compounds are represented by both names and chemical structures.

GC Data Library: Includes 224,038 Kovacs indices for 21,847 compounds, an increase of over 50% from the previous version. Data include both non-polar and polar columns (NIST 05 had only non-polar columns). Most values were abstracted from the open literature and then compared to replicate values (average of 10 per compound) and estimates to find and remove errors.

MS/MS Spectra: This release greatly expands our collection of MS/MS spectra by 250% to 5,308 different precursor ions. A large fraction of the new spectra are for contaminants and metabolites.

Some enhancements were also made to the MS Search Software, such as

New in NIST 05

NIST 05 made the following major changes since NIST 02.

EI Library: This now contains 190,825 spectra of 163,198 different chemical compounds. In addition to the new spectra, important quality improvements have been made in both spectra and compound identification information. The binary format has not changed from the 2002 version, although several new files have been added that associate equivalent compounds and link individual compounds to the retention index library (see below).

GC Data: This is a new addition, containing 121,112 Kovats Retention Index values for 25,893 compounds on nonpolar columns, 12,452 of which are compounds represented in the Electron Ionization Library. Full annotation is provided, including literature source and measurement conditions. These are provided in a format accessible by our Search Program.

MS/MS Library: This is a new addition, containing 5,191 spectra of 1,943 different ions (1,671 positive and 341 negative ions).

Latest new features in the program and database:

New in NIST 02 and previous versions

NIST 02 made the following major changes since NIST 98 and previous versions.

The previous version (NIST 98) provided for a 75% increase in coverage and this latest release (NIST 02) provides for an additional 35% increase in coverage.  This was accomplished primarily by the addition of complete, high quality spectra either measured specifically for the library or taken from major practical collections, including:

NIST 02 contains spectra of more than 147,000 compounds along with associated chemical identification data including chemical structures, synonyms, and other of relevant information. The best quality spectra are placed in the Main Library; and good-quality, alternate spectra are provided in the Selected Replicates Library, bringing the total number of spectra to about 175,000. This release represents the largest increase in both quality and coverage in the 25-year history of the NIST/EPA/NIH Mass Spectral Database--and for the first time that it can be stated that the library has been fully evaluated.  The objective of this effort was to provide the best possible reference library for compound identification by mass spectral library searching.

System Requirements

Complete installation (libraries, NIST MS Search program, and AMDIS) requires ~400 MB of free hard disk space. The MS search program requires Windows NT 4.0, Windows 2000, XP, or Vista.

Note for old ChemStations (B1701BA): the error about $_ undefined can be resolved by replacing $_(number, string) with string in the ChemStation macros. Contact us for details if you run into this.

Note for Windows NT 4: You may need to download the older AMDIS version 2.63. Running 2.66 on NT 4 gives the error "AMDIS_32.EXE - Entry Point Not Found - The procedure entry point MonitorFromPoint could not be located in the dynamic link library USER32.dll".

Demo Version

Download NIST 08 Demo. The demo differs from the full version mainly in that it contains a very small subset of the database. Also, this is a demo of only the standard version of NIST (does not contain native formats in the ChemStation and multiformat versions of NIST).

Note: In order for your MS data system to recognize the demo version, you may need to edit the file "c:\windows\win.ini" (or "c:\winnt\win.ini") to change the line "[NISTMSDEMO]" to "[NISTMS]".

Download AMDIS 2.65 (free) (this is included in demo and need not be downloaded separately)

Ordering

UOM=EA
Part No. Description est
wt.
Quantity
In Stock
Price Quantity
to order
New Licenses:
641010 NIST 08 Library and Search Program 0 3$2095.00(*B)
641010HP NIST 08 Library and Search Program plus libraries in Agilent ChemStation format 0 7$2395.00(*B)
641010MF NIST 08 Library and Search Program plus libraries in multiple native formats 0 0(#)$2869.00
Upgrades:
641010UG NIST 08 Library and Search Program (upgrade from any previous version of NIST) 0 6$1095.00(*B)
641010HPUG NIST 08 Library and Search Program plus libraries in Agilent ChemStation format (UPGRADE from any previous version of NIST) 0 7$1295.00(*B)
641010MFUG NIST 08 Library and Search Program plus libraries in multiple native formats (UPGRADE from any previous version of NIST) 0 0(#)$2469.00
(*_) Marked parts have bulk quantity discount pricing:
Discount code 'B' -- 3 or more: 5% off; 10 or more: 7% off.
(#) Standard lead-time for out-of-stock items is approximately two weeks.
shopping cart Ordering information. International (non-US) prices available through your local dealer.

Which version to buy? Contact us if you have any questions if unsure.

Summary of the different NIST versions:

Instructions by MS manufacturer:

(The above list is somewhat of a moving target. Please drop us an e-mail if anything here is incomplete.)

Other databases available: The NIST 08 is a strongly validated and extensively used MS library of general compounds recommended for most all users. Users looking for a larger library or libraries dedicated to certain classes of specialty compounds may wish to augment their NIST database with one of the Wiley MS libraries.

Additional Information

Application Note (NIST 98).

TIP: Dr. Sparkman at ChemUserWorld has some additional tips on using NIST with Agilent ChemStation, including using separate NIST and Wiley databases on ChemStation.

Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551.
© 1996-2009 Scientific Instrument Services, Inc. [Trademarks]
Search:
search by keywords or part number (e.g. "G75K")
SIS News
SIS E-Mail Newsletter [22 Sep 2009]
Monthly or weekly notices of new products or special promotions.
Current issue:
  • New low cost rotary vane vacuum pumps
  • All-in-one two stage vacuum pump filter
  • New Agilent 5973/75 source heater and temperature sensor
  • Low cost oil mist eliminator elements.
SIS MS Source Newsletter [Spring 2009]
Quarterly company newsletter for the mass spec community.