ISSUE No. 7
REVIEW DATE: 04/96
REVISION DATE: 04/96
PRODUCT/TRADE NAME: ELECTROTEMP CEMENT (POWDER) - NO. 8
SUPPLIER: SAUEREISEN
ADDRESS:
160 GAMMA DRIVE
PITTSBURGH, PA 15238
EMERGENCY PHONE NUMBERS
BUSINESS HOURS: 412/963-0303
CHEMTREC: 800/424-9300
CHEMICAL FAMILY: MAGNESIUM PHOSPHATE CEMENT; aMoHx(POy)z * bH2O
LISTED AS A CARCINOGEN:
OHSA: NO NTP: NO IARC: YES
SILICA IS LISTED ON IARC AS A SUSPECTED CARCINOGEN.
CHEMICAL COMPONENTS OF THIS PRODUCT WHICH ARE PRESENT IN REPORTABLE AMOUNTS AND ARE LISTED IN SECTION 313 OF THE EMERGENCY PLANNING AND COMMUNITY RIGHT-TO-KNOW ACT OF 1986 (SARA TITLE III) ARE SHOWN BELOW WITH THEIR CAS REGISTRY NUMBERS AND MAXIMUM COMPOSITION BY WEIGHT.
NONE
| CLASSIFICATION | CHEMICAL NAME | CAS# | TLV | PEL |
|---|---|---|---|---|
| HAZARDOUS: | SILICA | 14808-60-7 | 0.1 mg/m3 | 0.1 mg/m3 |
| ZIRCONIUM SILICATE | 14940-68-2 | 5 mg/m3 | 5 mg/m3 |
HMIS RATINGS
HEALTH: 1
FLAMMABILITY: 0
REACTIVITY: 0
PERSONAL PROTECTION: A
NA = NOT APPLLICABLE; NE = NOT ESTABLISHED; D = DECOMPOSES
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.