SECTION I - PRODUCT IDENTIFICATION
MANUFACTURERS NAME: Econoline Abrasive Products, Inc.
335 N. Griffin Street Phone: 616-846-4150 Grand Haven, MI 49417 TRADE NAME: Glass Beads DOT Class/ID Number: CHEMICAL & COMMON NAME(S): Glass Soda-Lime Type FORMULA: Sodium Aluminum Silicate Base Glass
SECTION II - HAZARDOUS INGREDIENTS
OSHA Potential Hazardous Ingredient(s):
Component CAS# % ACGIH-TLV OSHA-PEL
NA NA NA NA
To the best of our knowledge, this material is non-hazardous as per OSHA 29CFR 1910.1200.
SECTION -III PHYSICAL DATA
Boiling Point (deg. F): NA Specific Gravity (H2O=1): NA Vapor Pressure (mm Hg): NA Volatiles by Volume (5): NA Vapor Density (AIR=1): NA Evap. Rate (butyl acetate=1): NA Appearance & Odor: NA Melting Point: NA
SECTION IV - FIRE AND EXPLOSION HAZARD
Flash Point (Method Used): NA Flammable Limits LEL: NA UEL: NA
Extinguishing Media: NA
Special Fire Fighting Procedures: NA
Unusual Fire & Explosion Hazards (See Reactivity Section for other physical hazards): NA
SECTION V - REACTIVITY DATA
Stability: Unstable: NA Stable: NA Conditions to Avoid: NA
Incompatibility (Materials to Avoid): NA
Hazardous Decomposition Products: NA
Hazardous Polymerization:
May Occur: NA Will Not Occur: NA Conditions to Avoid: NA
SECTION VI - HEALTH HAZARD DATA
Primary Routes of Entry: Inhalation - Ingestion
Used as a Carcinogen?: NO
Symptoms and Effects of Overexposure: Excessive dust may cause irritation of the eyes and the respiratory system.
Emergency and First Aid Procedures: If some beads or dust get in the eye, flush the affected eye(s) with water of commercial eye wash. If unable to remove the bead/dust by this method, seek medical care.
SECTION VII - SPILL OF LEAK PROCEDURES
STEPS TO BE TAKEN IN CASE MATERIAL IS RELEASED OR SPILLED: Vacuum or sweep up excess material to avoid a possible slipping hazard.
WASTE DISPOSAL METHOD: Dispose of in compliance with local, state and Federal Regulations.
SECTION VIII - RECOMMENDED CONTROL MEASURES
Respiratory Protection: Nuisance dust respirator if your use of the product creates a dust.
Ventilation:
Local Exhaust: As required for nuisance dust
Mechanical (general): As required for nuisance dust
Special: NA
Protective Gloves: As required per job
Eye Protection: Safety glasses-goggles for dust
Other Protective Equipment: NA
Special Protective Measures for Repair and Maintenance of contaminated Equipment: NA
SECTION IX - SPECIAL PRECAUTIONS
Precautions to be Taken in Handling and Storing (including appropriate hygienic practices): NA
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.