Scientific Instrument Services, Inc.  Supplies and Services for Mass Spectrometers, Gas Chromatographs, and Liquid Chromatographs.
Contact Us view shopping cart

 MSDS SHEET - Micro-Finish


SECTION 1 MANUFACTURERS INFORMATION    
PRODUCT NAME:   MICRO-FINISH        
PRODUCT DESCRIPTION: WHITE SLURRY, NO ODOR      
CHEMICAL FAMILY:   LIQUID POLISH      
REVISION DATE:   May 10, 2002        
             
SECTION 2 INGREDIENTS, COMPOSITION    
             
CHEMICAL NAME CAS REGISTRY NO.   % WT CHEMICAL NAMES   NOTES  
      WATER   SECTION 313 SUPPLIER NOTIFICATION: "1" IDENTIFIES CHEMICAL INGREDIENTS  
64742-89-9   10-12 NAPTHA   SUBJECT TO REPORTING REQUIREMENTS OF SECTION 313 OF THE EMERGENCY
064741-41-9 7-10 MINERAL SPIRITS PLANNING AND COMMUNITY RIGHT-TO-KNOW-ACT OF 1986.
66402-68-4   7-10 ALUMIA        
68915-31-1   T HEXAMETH PHOSPHATE      
68155-20-4   T EMULSIFIER        
9003-01-4   T SUSPENDING AGENT      
NE   T THICKENING AGENT      
112-80-1   T OLEIC ACID        
             
SECTION 3 HAZARDS IDENTIFICATION      
             
HEALTH --------------- 0     INSTABILITY -------------------------- 0  
FIRE -------------------- 0     OTHER --------------------------------- X  
(0 = INSIGNIFICANT;  1 = SLIGHT;  2 = MODERATE ;  3 = HIGH;  4 = EXTREME)    
HAZARD SIGNAL (SHORT TERM CONTACT OR INHALATION ONLY)    
THRESHOLD LIMIT VALUE:   NE, BLENDED PRODUCT. SEE SECTION 2  FOR INFORMATION ON LISTED INGREDIENTS
PRIMARY ROUTES OF ENTRY:   EYE CONTACT      
EFFECTS OF ACUTE OVEREXPOSURE:        
  EYES:     IRRITATION      
  SKIN:     DRYING OF SKIN POSSIBLE WITH PROLONGED USE  
  INHALATION:   MIST OF PRODUCT OR SOLUTION COULD CAUSE POSSIBLE RESPIRATOR TRACT IRRITATION
  SWALLOWING:   STOMACH UPSET POSSIBLE    
EFFECTS OF CHRONIC OVEREXPOSURE: UNKNOWN; NONE EXPECTED BEYOND ACUTE EFFECTS  
CARCINOGENICITY:     THIS PRODUCT OR ITS INGREDIENTS HAVE NOT BEEN IDENTIFIED AS A CARCINOGEN
        OR PROBABLE CARCINOGEN BY NTP, IARC MONOGRAPH OR OSHA
MEDICAL CONDITIONS AGGRAVATED BY EXPOSURE: NONE KNOWN OR EXPECTED    
             
SECTION 4 FIRST AID MEASURES      
             
EYES:   IMMEDIATELY FLUSH WITH COOL RUNNING WATER HOLDING EYE LIDS APART. REMOVE CONTACT LENSES IF PRESENT
    AND CONTINUE FLUSHING FOR 15 MINUTES. GET MEDICAL ASSISTANCE IF IRRITATION PERSISTS OR IS SEVERE.
SKIN:   FLUSH THOROUGHLY WITH RUNNING WATER. REMOVE CONTAMINATED CLOTHING AND WASH BEFORE REUSE.          
    IF IRRITATION DEVELOPS AND PERSISTS, GET MEDICAL ADVICE OR ASSISTANCE.  
INHALED:   REMOVE TO FRESH AIR. IMMEDIATELY CALL FOR MEDICAL ADVICE OR ASSISTANCE IF BREATHING DIFFICULTY
    OR IRRITATION IS SEVERE OR CONTINUES.    
SWALLOWED: RINSE MOUTH WITH LARGE AMOUNTS OF WATER. DRINK WATER, MILK OR OTHER FLUIDS TO DILUTE. DO NOT INDUCE
    VOMITING. CALL FOR MEDICAL ADVICE OR ASSISTANCE IF DIFFICULTIES AND DISCOMFORT DEVELOP AND CONTINUE.
             
             
             
SECTION 5 FIRE FIGHTING MEASURES      
             
FLASH POINT:   NONE   FLAMMABLE LIMITS LEL-UEL NA  
EXTINGUISHING MEDIA: AS NEEDED FOR SURROUNDING FIRE    
SPECIAL FIRE FIGHTING PROCEDURES: FOR ANY CHEMICAL FIRE WEAR SELF CONTAINED BREATHING APPARATUS AND PROTECTIVE
        CLOTHING TO PREVENT CONTACT    
UNUSUAL FIRE AND EXPLOSION HAZARDS: NONE      
HAZARDOUS COMBUSTION PRODUCTS: NE      
             
             
SECTION 6 ACCIDENTAL RELEASE MEASURES    
             
SMALL SPILLS: FLUSH TO DRAIN WITH EXCESS WATER    
LARGE SPILLS: STOP SOURCE IF SAFE TO DO SO. CONTAIN SPILLED MATERIAL AND KEEP FROM DISCHARGING
    TO SURFACE WATERS. RECOVER TO DRUM FOR LATER USE. TREATMENT OR DISPOSAL. FLUSH RESIDUAL TO DRAIN.
    NOTIFY LOCAL, STATE OR NATIONAL AUTHORITIES IF REQUIRED    
DISPOSAL:   NORMALLY SEWER DISPOSABLE IN DILUTE SOLUTIONS. CHECK WITH LOCAL AUTHORITIES ABOUT ANY POSSIBLE
    RESTRICTIONS.        
             
SECTION 7 HANDLING AND STORAGE      
             
HANDLING:   RINSE AFTER USE. AVOID BREATHING MISTS OF PRODUCT OR SOLUTION  
STORAGE:   KEEP CONTAINERS TIGHTLY CLOSED. DO NOT FREEZE OR STORE IN EXCESSIVE HEAT
             
SECTION 8 EXPOSURE CONTROLS, PERSONAL PROTECTION    
             
VENTILATION: NORMALLY NOT NECESSARY. IF MISTS ARE GENERATED HAVE GENERAL OR LOCAL VENTILATION TO AVOID
    AVOID BREATHING IRRITATING MISTS.    
RESPIRATOR: NONE NORMALLY REQUIRED. NIOSH/MSHA APPROVED RESPIRATOR WHERE CONDITIONS MAY CAUSE EXPOSURE          
    LIMITS TO BE EXCEEDED FROM MISTS OF PRODUCT OR SOLUTION.    
EYE PROTECTION:   GLASSES, GOGGLES, OR FACE SHIELD WHERE CONDITIONS MAY CAUSE EXCESSIVE EYE EXPOSURE.
PROTECTIVE CLOTHING: CHEMICAL RESISTANT, IMPERMEABLE GLOVES AS NEEDED TO PREVENT EXCESSIVE CONTACT.
      FULL BODY COVERING AND SHOES AS NEEDED TO PREVENT EXCESSIVE CONTACT.
OTHER PROTECTIVE EQUIPMENT OR MEASURES: EYE WASH STATIONS OR RUNNING WATER IN THE WORK AREA.
             
SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES    
             
BOILING POINT:    147° F   VAPOR PRESSURE (MM HG@70°) NE  
SPECIFIC GRAVITY:   1.084   VAPOR DENSITY (AIR =1) NE  
PERCENT VOLATILE:   0   EVAPORATION RATE (ETHER=1) NE  
SOLUBILITY IN WATER: COMPLETE   PH 7.6  
APPEARANCE AND ODOR: SEE SECTION 1   V.O.C. NE  
             
SECTION 10 STABILITY AND REACTIVITY      
             
STABLE:     YES. HAZARDOUS POLYMERIZATION WILL NOT OCCUR    
CONDITIONS TO AVOID: CONTACT WITH INCOMPATIBLE MATERIAL (SEE BELOW)    
INCOMPATIBLE MATERIALS: NE AT THIS TIME      
             
NE = NOT ESTABLISHED          
NA = NOT APPLICABLE          
             
             
        DISCLAIMER    
             
THE ABOVE INFORMATION IS, TO THE BEST OF OUR KNOWLEDGE, CURRENT, ACCURATE AND COMPLETE
BASED ON INFORMATION REASONABLY AVAILABLE TO US AS ON THE DATE OF PREPARATION OF THIS FORM.
HOWEVER, IT IS THE USER'S RESPONSIBILITY TO DETERMINE THE SAFETY, TOXICITY AND SUITABILITY  FOR
HIS OR HER OWN USE OF THE PRODUCT DESCRIBED HEREIN. SINCE THE ACTUAL USE BY OTHERS IS
BEYOND OUR CONTROL, NO GUARANTEE, EXPRESSED OR IMPLIED, IS MADE BY US AS TO THE EFFECTS
OF SUCH USE OR ON THE SAFETY OR TOXICITY OF THIS PRODUCT. NOR DO WE ASSUME ANY LIABILITY
ARISING OUT OF THE USE BY OTHERS OF THE PRODUCT. NOR IS THE INFORMATION HEREIN TO BE
CONSTRUED AS ABSOLUTELY COMPLETE, SINCE ADDITIONAL INFORMATION MAY BE NECESSARY
OR DESIRABLE WHEN EXCEPTIONAL CONDITIONS OR CIRCUMSTANCES EXIST OR BECAUSE OF
APPLICABLE LAWS OR REGULATIONS.      
             

 

Other pages linking here:
back to top
Send comments on this page
Contacting our Customer Service Department--comments, questions, or anything can't find?
Call, e-mail, FAX, or type your comments below:
Contact details (optional, but required for us to reply or quote):
Name: Organization/Country:
Email: Phone/fax:
Regular business hours - 8:00 AM to 5:30 PM EST, M-F. E-mail replies normally expected within one business day.
PHONE: (908)788-5550;   FAX: (908)806-6631;   E-MAIL:
WEB: www.sisweb.com
ADDRESS: Scientific Instrument Services, 1027 Old York Rd., Ringoes, NJ 08551-1054.
© 1996-2012 Scientific Instrument Services, Inc. [ Terms | Trademarks | Privacy ]
Search:
search by keywords or part number (e.g. "G75K")
Navigation

SIS Newsletter
Covers SIS products, services, promotions, news, and other mass spectrometer related information.