SilTite FingerTite is the next generation ferrule system for gas chromatography systems delivering an easy leak free installation for capillary columns without the use of any tools.
25% discount on selected items until October 31, 2010.
Easy • Reliable • Leak Free • No Tools
What is SilTite™ FingerTite? It’s a GC ferrule that has been designed to be installed only with the force of your fingers (no tools required) delivering an easy, leak and maintenance free seal.
Who will benefit from this product? If you are running a capillary column equipped gas chromatography system, SilTite FingerTite will simplify your column installation process giving you less hassle and more time for chromatography.
GCMS users SilTite FingerTite has been developed with the unique, leak and air free properties of SilTite ferrules, resulting in superior air tightness to reduce background noise in sensitive MS applications meaning you can use them on your MS interface with confidence.
How is it a ‘next generation’ connection? See charts below.| 100 % Graphite | Graphite Vespel® | SilTite FingerTite | |
|---|---|---|---|
| Mechanical Strength | Soft | Hard | Hard |
| Temperature Limit | 450 °C | 350 °C | No practical limit |
| Grip strength on column | Soft | Moderate | Strong |
| Doesn’t need retightening after installation | Y | N | Y |
| Ideal for GC-MS applications (minimal porosity) | N | Y | Y |
| No tools required for installation and removal | N | N | Y |
| Permanent positioning of ferrule | N | N/Y | Y |
| No Deterioration | N | N | Y |
| Cannot break the capillary column with over-tightening | N | N | Y |
| No Column Creep | N | N | Y |
| Chemically inert | N | N | Y |
How do I install SilTite FingerTite? The SilTite FingerTite ferrule requires a unique adapter to enable the finger force connection. Purchase one of the following starter kits with the corresponding adapters for your system, complete the once off 5 minute install using the instructions provided and you are ready to go! The system requires no permanent instrument modifications, so if you need to switch back to conventional connections this can be done quickly and easily.
There are 25% discounts on part # 073610, 073612, 073620, 073621 until October 31, 2010.
| Part No. | Description | UOM | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|---|
| 073610 | SILTITE FINGERTITE AGILENT INJ / FID STARTER KIT | EA | 0 | 0(#) | $268.00 | |
| 073612 | SILTITE FINGERTITE AG-MS STARTER KIT | EA | 0 | 0(#) | $278.00 | |
| 073620 | SILTITE FINGERTITE SHIMADZU 2010 INJ STARTER KIT | EA | 0 | 0(#) | $232.00 | |
| 073621 | SILTITE FINGERTITE SHIMADZU 2010 INJ / MS STARTER KIT | EA | 0 | 0(#) | $252.00 | |
| 073628 | SILTITE FINGERTITE SHIMADZU 17A INJ STARTER KIT | EA | 0 | 0(#) | $232.00 | |
| 073629 | SILTITE FINGERTITE SHIMADZU 17A INJ / MS STARTER KIT | EA | 0 | 0(#) | $252.00 | |
| Replacement Items | ||||||
| 073630 | SILTITE FINGERTITE FERRULE 0.4MM PK10 | PK | 0 | 0(#) | $56.00 | |
| 073631 | SILTITE FINGERTITE FERRULE 0.5MM PK10 | PK | 0 | 0(#) | $56.00 | |
| 073633 | SILTITE FINGERTITE BLANKING FERRULE PK 2 | PK | 0 | 0(#) | $32.00 | |
| 073636 | SILTITE FINGERTITE FEMALE NUT PK5 | PK | 0 | 0(#) | $90.00 | |
| 073640 | SILTITE FINGERTITE AGILENT INJ BASE SEAL PK2 | PK | 0 | 0(#) | $63.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | ||||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
||||||
Q1 Can I reuse the ferrules?
A1 Once the ferrule is crimped onto the tubing using the ferrule installation tool, the fitting is permanent. However, the column can be removed and reinserted multiple times without tools.
Q2 Can I break my column if overtighten the nut?
A2 No - with the SilTiteâ„¢ FingerTite system you cannot generate enough force with your fingers to break the column. Never use pliers or any other tool on the nut or you will possibly damage the adapter as well as break the column.
Q3 Can I touch the nut even when the oven is at 200 ºC?
A3 No - the nut will be at the oven temperature so it will be too hot to touch. However, the nut is designed to dissipate the heat from the injector/detector/transfer line, so that when the oven is cool you can change the column without waiting for the injector/detector to cool down. For Mass Spectrometers always follow the manufacturer’s recommendations to vent the system.
Q4 Can I reuse the SilTiteâ„¢ FingerTite nuts?
A4 Yes, the nuts can be reused although the nuts will be permanently fixed to the column with the ferrule. Spare nuts can be purchased if more are required.
Q5 What’s included in the starter kit?
A5 Each starter kit includes all the parts necessary to convert one GC system (one injector and one detector) to the SilTiteâ„¢ FingerTite system suitable for installing 0.1 - 0.25 mm ID capillary columns. In addition there are 5 SilTiteâ„¢ FingerTite nuts, one packet (10 ferrules) of 0.4 mm ID SilTiteâ„¢ FingerTite ferrules and a ferrule install tool which allows you to seat the ferrule in the correct position on the capillary column.
Q6 Can I use any dimension of GC capillary column?
A6 SilTiteâ„¢ FingerTite is suitable for any GC capillary column of nominal ID 0.1 - 0.25 mm (0.4 mm ID SilTiteâ„¢ FingerTite ferrule) and 0.32 mm (0.5 mm ID SilTiteâ„¢ FingerTite ferrule).
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.