WarmMark Time/Temp Tags - Short Run
The WarmMark Short Run Time Temp/Tag is a widely adopted design to record exposure and duration of exposure above the activation temperature. Activated by warming, the red dye will permanently color in the recording windows to create an immediate record of a temperature excursion
| 3TM Specifications | |
|---|---|
| Accuracy | ±1°C |
| Shipping | No special packaging required for shipping |
| Storage | Must be stored at least 5°C colder than the response temperature |
| Shelf Life | 24 months from invoice date when stored according to requirements |
| Preconditioning | Must be preconditioned prior to use, see WarmMark Instructions |
| Presentation | Self-adhesive backing on release liner. |
| Dimensions | 1.80" x 0.80" x 0.10" (46mm x 20mm x 2.5 mm) |
| 3TM Run-Out Time* Comparison Chart | ||||
|---|---|---|---|---|
| Part# | Response Temperature | Increment #1 | Increment #2 | Increment #3 |
| 3TM-18C | -18°C/0°F | <1 hour | 3 hours | 12 hours |
| 3TM0C | 0°C/32°F | 2 hour | 12 hours | 48 hours |
| 3TM+5C | 5°C/41°F | <30 minutes | 2 hours | 8 hours |
| 3TM+8C | 8°C/46°F | 2 hour | 12 hours | 48 hours |
| 3TM+10C | 10°C/50°F | 2 hour | 12 hours | 48 hours |
| 3TM+20C | 20°C/68°F | 2 hour | 12 hours | 48 hours |
| 3TM+25C | 25°C/77°F | <30 minutes | 2 hours | 8 hours |
| 3TM+30C | 30°C/86°F | <30 minutes | 2 hours | 8 hours |
| 3TM+37C | 37°C/99°F | <30 minutes | 2 hours | 8 hours |
*Time required for all three windows to turn red when the tag is exposed te a constant temperature of 2°C above the response temperature. The higher the exposure temperature is above the response temperature, the faster the run-out time
| UOM=PK | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| 3TM18C | WARMMARK TEMP TAGS 10/PK 10 PER PACK - 2 PACK MINIMUM; -18C/0 F | 0 | 0(#) | $21.00 | |
| 3TMOC | WARMMARK TEMP TAG 10/PK 10 PER PACK - 2 PACK MINIMUM; 0 C/32 F | 0 | 0(#) | $21.00 | |
| 3TM5C | WARMMARK TEMP TAG 10/PK 10 PER PACK - 2 PACK MINIMUM; 5 C /41 F | 0 | 0(#) | $15.00 | |
| 3TM8C | WARMMARK TIME TAG 10/PK 10 PER PACK - 2 PACK MINIMUM; -180C/0 F | 0 | 0(#) | $21.00 | |
| 3TM10C | WARMMARK TEMP TAGS 10/PK 10 PER PACK - 2 PACK MINIMUM; 10 C/50 F | 0 | 0(#) | $21.00 | |
| 3TM20C | WARMMARK TEMP TAG 10/PK 10 PER PACK - 2 PACK MINIMUM; 20 C/58 F | 0 | 0(#) | $21.00 | |
| 3TM25C | WARMMARK TEMP TAG 10/PK 10 PER PACK - 2 PACK MINIMUM; 25 C/77 F | 0 | 0(#) | $21.00 | |
| 3TM30C | WARMMARK TEMP TAG 10PK 10 PER PACK - 2 PACK MINIMUM; 30 C/86 F | 0 | 0(#) | $21.00 | |
| 3TM37C | WARMMARK TEMP TAG 10PK 10 PER PACK - 2 PACK MINIMUM; 37 C/99 F | 0 | 0(#) | $21.00 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.