Thermocouple Probes
Complete your thermometer or data logger purchase with a Telatemp thermocouple probe. Available in stainless steel sheath or flexible wire configurations and equipped with a standard flat pin mini-connector.
| General Purpose Probes | ||
|---|---|---|
| These 316 stainless probes are used to measure liquids, gases, and small object surfaces. Grounded junction. Time constant: 3 seconds in liquids | ||
| Item Number | Type | Temperature Range |
| 851755 | J | -310°F to 1400°F (-190°C to 760°C) |
| 851655 | K | -418°F to 1650°F (-250°C to 899°C) |
| 850055 | T | -418°F to 752°F (-250°C to 400°C) |
| 851755 | E | -418°F to 1600°F (-250°C to 871°C) |
| Penetration Probes | ||
| Designed to penetrate the surface fo the material providing a more accurate reading. Glass-filled nylon handle. Grounded junction. Response time 30 seconds in liquids | ||
| Item Number | Type | Temperature Range |
| 851665 | K | -418°F to 1650°F (-250°C to 899°C) Standard |
| 851667 | K | -418°F to 1652°F (-250°C to 900°C) 6" Heavy Duty |
| Small Diameter Penetration Probes | ||
| The hypodermic tip is ideal with soft of semi soft materials. Sheath is MgO-filled 316 SS. Grounded junction. Time constant: 3 seconds | ||
| Item Number | Type | Temperature Range |
| 9360102 | J | -310°F to 1300°F (-190°C to 704°C) |
| 9360104 | K | -418°F to 1500°F (-250°C to 816°C) |
| 9360106 | T | -418°F to 650°F (-250°C to 343°C) |
| Food Service Thermocouple Probe with Hypodermic Tip | ||
| The 4" long (0.063" dia.) SS probe is connected to a 1.5" long 316 SS sheath and a 4 foot long straight armored cable terminated with a miniconnector. Grounded junction. 15 second response time. | ||
| Item Number | Type | Temperature Range |
| 9360720 | J | -310°F to 700°F (-190°C to 371°C) |
| 9360722 | K | -418°F to 700°F (-250°C to 371°C) |
| 9360724 | T | -418°F to 700°F (-250°C to371°C) |
| Bolt-on Surface Themocouple Probe | ||
| The 304 SS washer (0.28" I.D., 0.62" O.D.) allows this probe to be bolted to fixed surfaces for continuous monitoring. The washer is directly affixed to a 5 foot straight 304 SS armor over fiberglass wire. Grounded junction. 15 second response time | ||
| Item Number | Type | Temperature Range |
| 851785 | J | -310°F to 900°F (-190°C to 482°C) |
| 851685 | K | -418°F to 900°F (-250°C to 482°C) |
| 850085 | T | -418°F to 750°F (-250°C to 399°C) |
| Angled Surface Probes | ||
| Designed to monitor a wide range of flat surfaces. Response time: 30 seconds | ||
| Item Number | Type | Temperature Range |
| 851661 | K | -418°F to 1200°F (-250°C to 649°C) 45° Angle |
| 851663 | K | -418°F to 1200°F (-250°C to 649°C) 90° Angle |
| Flexible Wire Probes | ||
| For running in through chamber doors or taping down to surfaces | ||
| Item Number | Type | Temperature Range |
| PTFE/Plastisol | ||
| 854000 | K | -310°F to 900°F (-190°C to 482°C) 3' |
| 854001 | K | -418°F to 221°F (-250°C to 105°C) 6' |
| 854002 | K | -418°F to 221°F (-250°C to 105°C) 9' |
| High-Temp Fiberglass Braid 3' | ||
| 854100 | K | -100°F to 900°F (-190°C to 482°C) |
| PVC Insulated Wire Epoxy Coated Tip 10' - Time constant: 5 seconds. | ||
| 846602 | J | -310°F to 221°F (-190°C to 105°C) |
| 846604 | K | -418°F to 221°F (-250°C to 105°C) |
| 846606 | T | -418°F to 221°F (-250°C to 105°C) |
| High Temperature Insulated Wire Exposed Junction 10' - Time constant: 3 seconds. | ||
| 846722 | J | -310°F to 1300°F (-190°C to 704°C) |
| 846724 | K | -418°F to 1300°F (-250°C to 704°C) |
| FEB insulated Probe with PTFE Coated Junction 10' - Time constant: 3 seconds | ||
| 846681 | J | -310°F to 400°F (-190°C to 204°C) |
| 846682 | K | -418°F to 400°F (-250°C to 204°C) |
| 846683 | T | -418°F to 400°F (-250°C to 204°C) |
| Economical PVC Insulated Wire Probe 3' - Response Time: 3 seconds | ||
| 851500 | J | -310°F to 221°F (-190°C to 105°C) |
| 851501 | K | -310°F to 221°F (-190°C to 105°C) |
| 851502 | T | -310°F to 221°F (-190°C to 105°C) |
| Extension Cables with Mini-Connectors - Max Temperature: 221° F (105°C) | ||
| 851630 | K | T/C Extension Cable 10' |
| 851635 | K | T/C Extension 25' |
| 851650 | K | T/C Extension Cable 50' |
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.