PC Transit ThermometerCompact .5°C accuracy 16,000 point datalogger records temperature vs. time of temperature sensitive products in transit - recovers data on a PC
The Telatemp PCT-2000 Transit Thermometer is a high performance, tamperproof .5°C accuracy real-time vs. temperature recording system designed to cost effectively protect the quality and safety of critical temperature sensitive goods in transit.
The Telatemp PC Transit Thermometer system consists of: A compact, battery operated, self contained data logger module that travels with a shipment and the support package: a data recovery interface with 9-pin serial connector that cradles the data logger to transfer data to an IBM PC or compatible, Telatemp Transit Software for data logger set up, data capture, display, analysis, graphing and printing and the key ring magnetic starter.
At the heart of the PC Transit Thermometer system is the .5°C accuracy solid state PCT-2000-DLM Data Logger Module which senses and records up to 16,000 temp vs. time points from -40°C to 70°C. Timing accuracy is 40 sec./month. The rate of data sampled can be programmed for intervals from one to 255 minutes. Recordings are indexed to "real time", and can be read in local time, sender's time, or elapsed time.
Housed in a rugged polycarbonate water-resistant case, the compact 2.5 oz, 3" dia. x .75" data logger module can operate under adverse environmental transit conditions with 100% reliability - trip after trip.
The non-volatile "permanent" memory assures that all recordings will be retained in memory, even if the 3.6V lithium battery becomes depleted or removed.
To start recording a trip with the data logger is simple. It can be pre-programmed to start at a particular time. Or it can be started by the shipper with a convenient Key Ring Magnetic Starter that is swiped across the logger's back side. Beeping tones tell when the logger is operating. The logger then travels with the load to record temp/time trip activity.
At the destination, the trip data can be quickly retrieved by placing the logger into its Data Recovery Interface PC-2000-DRI and loading the stored information into an IBM PC or compatible using the Telatemp Transit Software. Recorded data is totally protected against unauthorized use, tampering or duplication with a secure password programmed in software.
The menu driven Telatemp Transit Software is easy to use. It sets up the parameters for temp/time recordings in the Data Logger Module, including the interval between recordings and the cargo's minimum and maximum safe temperature ranges. The trip number is automatically assigned for each use.
Recorded data can be displayed and printed in List and Graph modes in °C or °°F. A variety of options are available for formatting, printing, graphing and saving the data. Reports include a serial number, the trip number, sampling frequency, a summary of all measurements outside of the cargo's safe minimum and maximum temperatures. Also, time-stamped temperatures for an entire trip's recordings with out of spec temperatures noted with a * are listed.
The average temperature of the trip or any portion of the trip can be shown, along with the total number of logs and the number of readings outside of the safe temperature band.Trip data can be saved to disk in the Telatemp compact format to be queried at any time by the Transit Software, or as an ASCII file or .SLK file for export to popular spreadsheets, databases and word processing programs. Data can be output on popular printers.
| PC Transit Specifications | |
|---|---|
| Temperature Accuracy | ± 0.5°C (1.0°F) |
| Temperature Resolution | <1.1°C from -40°C to -20%deg;C <0.5°C from -20°C to 40%deg;C <1.1°C from 40°C to 70%deg;C |
| Sample Rate | Programmable - intervals of one minute to 255 minutes |
| Data Capacity | 16,000 data points nominal |
| Measuring Range | -40°C to 70°C (-40°F to 158°F) |
| Time Accuracy | 40 seconds per month. Logs in real time |
| Storage Temperature | Recommended less than 27°C (80°F) |
| Power Source | Replaceable 3.6 V lithium battery (included) 2 year life |
| Starting Device | On site activation by magnet contact or user programamable for activation at specific date and time |
| Function Check | Beeps on start up to confirm activation and beeps while logging |
| Software | Menu driven format using Windows |
| Data Recovery | Logger mates with Data Recovery Interface for connection to IBM compatible PC |
| Case Material | Logger and Interface are made of polycarbonate with plated metal contacts |
| Dimensions | Diameter: 3.00" (7.62 cm) excluding mounting lug Depth: 0.725" (1.84 cm) Mounting Hole Diameter: 0.32" (0.80 cm) |
| Unit Weight | 2.5 oz (70 grams) |
| UOM=EA | |||||
| Part No. | Description | est wt. |
Quantity In Stock |
Price | Quantity to order |
|---|---|---|---|---|---|
| PCT2000DLM | DATA LOGGER MODULE ONE INTERNAL TEMP SENSOR; 16000 POINTS | 0 | 0(#) | $160.00 | |
| PCTIHDLM | DATA LOGGER MODULE ONE INTERNAL TEMP SENSOR AND ONE INTERNAL HUMIDITY SENSOR | 0 | 0(#) | $293.00 | |
| PC2000LSPW | LOGGER SUPPORT PACKAGE INCLUDES DATA RECORVERY INTERFACE; WINDOWS TRANSIT SOFTWARE; KEY RING MAGNETIC STARTER | 0 | 0(#) | $140.00 | |
| PC2000DRI | DATA RECORVERY INTERFACE INLCUDES 9-PIN SERIAL PORT CONNECTOR FOR IBM AND COMPATIBLES | 0 | 0(#) | $75.00 | |
| PC2000TSWW | TRANSIT SOFTWARE-WINDOWS | 0 | 0(#) | $99.00 | |
| PC2000KRS | KEY RING MAGNETIC STARTER | 0 | 0(#) | $12.50 | |
| (#) Standard lead-time for out-of-stock items is approximately two weeks. | |||||
Ordering information.
International (non-US) prices available through your
local dealer.
|
|||||
![]() Yttria coated filament at start |
![]() Yttria coated filament after 16,000 cycles |
New Pumps Added to the List of LOW COST S.I.S. Rotary Vane
Vacuum Pumps - Save 35 - 50% off the price of comparable vacuum pumps.
Adixen (Alcatel) ACP Series Compact Dry Roughing Pumps - a frictionless pumping module, optimized for operation without internal lubricant.
- Direct Replacement for the Shimadzu QP5000 Filament.
PCI Analytics Products - product solutions for all Analytical Instrumentation
SilTite FingerTite, the next generation GC capillary ferrule system without the use of any tools.
(25% discount until Oct 31)
Direct Replacement for the Heated Capillary in the Thermo-Fisher Scientific TSQ & LCQ Mass Spectrometers now available
- Ideal for use in analytical instrumentation
- Will improve your laboratory workflow and reporting confidence in many ways
DigiVac Bench Top Vacuum Gauges
- Vacuum instrumentation with everything you need to go to work
Imtakt HPLC Columns
-offer a wide variety of unique stationary phases in their HPLC
columns
Programmable syringe pumps for controlled flow. Model NE-300 priced at only $275.00
NEW: Wiley 9th Edition - 660,000-850,000
spectra (a 65% increase).
NEW: Agilent 5973/75 Replacement Source
Heater and Temperature Sensor
NEW: SIS Direct Replacement
Filament for the Amatek/Dycor RGA Leak Detectors and Quadrupoles
(p/n 95381VE), which tests have shown increase service life.
NEW: SIS
Replacement Filter Elements For Edwards Oil Mist Eliminators -
Save up to 25% off the price of comparable Edwards replacement
elements.
Identify mass spectra via library
search with the fully-evaluated, most widely used mass spectral
reference library, compiled by the National Institute of Standards
and Technology (NIST).
View and capture images or video at
20x/400x power on a PC computer via attached USB cable.